6.0 Options
- 97 -
Accounts that do not allow for remote programming of the encryption field cannot be programmed (example: TL250 is a static encryption key and can-
not have encryption programmed remotely via this function).
This is a dynamic option that follows the assigned profile setting for the associated DNIS.
Option [408]: Encryption Randomization Interval
Default (0000) - Disabled
When this option is enabled, a randomized encryption key is passed to the transmitter at a regular programmed interval. Values are in minutes, and pro-
grammed in Hex. Minimum interval is 30 minutes (001E), up to a maximum of 65520 minutes or 45.5 days (FFF0).
When disabled (0000), encryption keys are not changed.
This option is also available to accounts in the DNIS profile range.
Note: This feature applies only to supported transmitter types.
Option [410]: Format ID Output
Default (00) - Disabled
This option enables the line card to output the format ID and profile used to receive a call. Output is either to a printer or to automation (for V1.31 and
up).
Option Values
00 – Disabled
01 – Output Format ID to printer only
02 – Output Format ID to automation only
03 – Output Format ID to printer and automation
The string is formatted as follows: (PP|FF|CC)
( = Hex 28
) = Hex 29
| = Hex 7C
PP = Profile number
FF = Format ID
CC = Channel number that received the signal (Phone line 01/02/03). The channel number output is in decimal format.
For printer output, the string is added to the event signal only (not the caller information output):
Example:
27 Nov 2009-18:51:25-01/06-SG -(PP|FF|CC)-RR-LLL-EVENT MESSAGE
For output to automation, the Format ID is added to the end of the automation string when enabled.
Example 1:
503045 187129E20001007(PP|FF|CC)
Example 2:
R03689[#1075|NRP](PP|FF|CC)
Format ID List
Format Description
Customer Visibility
Engineering Term
Format ID
Contact ID (4-Digit Account)
YES
CONTACT_ID_18
16
Contact ID (10-Digit Account)
YES
CONTACT_ID_58
4B
SIA FSK Level 1,2, and 3
YES
SIA_GENERIC
6B
DVACS
YES
DVACS
F1
SIM Number Output
YES
SIM Output
F2
Call Back Number
YES
Call_Back
F3
Sur-Gard Generic Internal Messages
YES
SG_GENERIC
FF
Option [411]: Account Code Substitution
Default [00] - Disabled
The SIA or Contact ID account code received in the data payload can be substituted with the FIBRO account code. This feature aids with account syn-
chronization with the alarm panel (e.g., where a universal transmitter is installed with an existing panel).
When enabled, the panel account code is replaced with the FIBRO account code using the same number of digits as the original signal. This changes the
output of both the Printer and SG-Automation, and the SG-Advanced automation. The FIBRO reception/Reply for signaling is not impacted.
For Example, if the panel SIA transmission code is 1234|Nri1\BA01, and the FIBRO Account code is 2222205555, the new SIA output from the
receiver is 5555|Nri1\BA01.