7.0 SG-DRL5/DRL5E/DRL5-2L PSTN Line Cards
- 109 -
When the DMP panel calls in and requests a time update, the receiver will respond with its current time and the offset value programmed in this section.
The time and date of the receiver with respect to the Greenwich Mean Time (GMT). The gg values in the update time and date command are determined
by starting at the GMT and moving westerly across the Earth. The table below will be used to determine the time zone for the option value.
Possible Values
Time Zone Description
Time Zone
Military
Civilian
00
Disabled
No time update will be sent to the panels
NA
24
Zulu
Greenwich Mean Time (GMT)
GMT (0)
23
Alpha
Central Europe Time (CET)
Middle European Time (MET)
GMT + 1
22
Bravo
Eastern Europe Time (EET)
GMT + 2
21
Charlie
Baghdad Time (BT)
GMT + 3
20
Delta
Gulf Standard Time (GST)
GMT + 4
19
Echo
Pakistan Time (PKT)
GMT + 5
18
Foxtrot
Bangladesh Time (BDT)
GMT + 6
17
Golf
Java Time (JT)
GMT + 7
16
Hotel
China Coast Time (CCT)
GMT + 8
15
India
Japan Standard Time (JST)
GMT + 9
14
Kilo
Guam Standard Time (GST)
GMT + 10
13
Lima
Solomon Islands Time (SBT)
GMT + 11
12
Mike
New Zealand Standard Time (NZST)
GMT + 12
01
November
Cape Verde Time (CVT)
GMT - 1
02
Oscar
Greenland Eastern Standard Time (VTZ)
GMT - 2
03
Papa
Eastern Brazilian Standard Time (BST)
GMT - 3
04
Quebec
Atlantic Standard Time (AST)
GMT - 4
05
Romeo
Eastern Standard Time (EST)
GMT - 5
06
Sierra
Central Standard Time (CST)
GMT - 6
070
Tango
Mountain Standard Time (MST)
GMT - 7
080
Uniform
Pacific Standard Time (PST)
GMT - 8
09
Victor
Alaska Standard Time (AKST)
GMT - 9
10
Whiskey
Hawaii Standard Time (HST)
GMT - 10
11
X-Ray
Nome Time (NT)
GMT - 11
SG-DRL5 Option 12F/22F: Online Time Out
Default (1E)
The Online Time Out option hangs up after a predetermined time delay. Time Out range can be programmed from 01 to 255 seconds (Hex 01 - FF) or
until the call is completed by the panel (Hex 00). When time out occurs, the line card hangs up and generates a signal to the printer and to the automation
(SIA identifier YS).
For Example:
Printer Message: "DRL Online Time-Out"
Automation: NYS0102 (shelf 01, slot 02).
00 = Disabled.
xx = Maximum number of seconds (Hex) before the receiver will automatically force termination of a call.
NOTE: Depending on the order of handshakes used, the default online timeout of 30 seconds may not allow sufficient time for all hand-
shakes to be sent before timeout occurs. This time may need to be extended to use these handshakes.
For UL Listed products, the permitted setting is 1E (30s).