5.0 Operation
- 54 -
5.5.3.3.3 SG-ALL
The Status banner displays SG-ALL when Option [401] is set to ALL Mode where the signals are outputted to TCP and SERIAL.
5.5.3.4 Standby mode
When the SG-CPM5 is not active, it is in Standby mode. In this mode, the Status banner displays "Standby" and the color of the banner is blue.
5.5.3.5 Manual mode
The SG-CPM5 is in Manual mode when
not
sending signals to automation software and when not the standby SG-CPM5.
When in Manual mode, the status banner displays "Manual" and the color of the banner is red. The number of pending events requiring acknow-
ledgment are displayed in this banner.
If acknowledgment events are pending, the ACK button, along with the status and trouble banners, slide over the line card widget. The pending events
are displayed where the user defined message and IPs were displayed. When an incoming alarm arrives, the buzzer sounds and the
ACK
button flashes.
If more events are present than can be displayed on the screen, a scroll bar is displayed to the right. Once an event is acknowledged, the display returns
to the top of the list.
A user must be logged in to acknowledge events.
On screens other than the Home screen, a red flashing ACK condition is shown via a flashing red screen border.
5.5.3.6 System trouble
The Trouble banner indicates the presence of system troubles and is located on the right of the Home screen beside the
ACK
button. If pending alarms
require acknowledgment, and the SG-CPM5 is in Manual mode, this bar covers the line cards.
While not on the Home screen, this banner remains visible in reduced size. The color of the banner is the same as on the Home screen.
5.5.3.6.1 No troubles
If no system troubles are present, the banner displays “No Troubles” and the color of the banner is green.
5.5.3.6.2 Troubles
If system troubles are present, the banner displays “X Troubles,” where X is the number of system troubles. The color of the banner is yellow.
Содержание System Five