Appendix D: Events and Messages
- 138 -
Description/event
Automation message
Printer message
Console Session Denied CPM 1
001000[#0000|NRD0001]
SG -01-000-0000-NRD0001-CONSOLE SESSION DENIED
Console Session Denied CPM 2
001000[#0000|NRD0002]
SG -01-000-0000-NRD0002-CONSOLE SESSION DENIED
Option Change Where ## is the option being changed
Value is the option setting in data or text depending
on option being set
NOTE: User passwords will be shown with
***** in place of data
001000[#0000|NLSSSss]
SG -01-000-0000-NLS01ss-Option Change: ## Value
Automation Time & Date Update Failed
001000[#0000|NRU0000]
SG -01-000-0000-NRU0000-Time&Date Update Fail
AHS Database Full
001000[#0000|NJOss01]
SG -01-000-0000-NJOss01-CPM AHS Database Full
Reset fallback
001000[#0000|NYY0000]
SG -01-000-0000-NYY0000-Reset SG-Fallback Initiated
Primary CPM Power Up where X.XX.XXX.XXX
is the software version information.
001000[#0000|NRR0100*
vX.XX.XX.XXX*]
SG -01-000-0000-NRR0100-Primary CPM Power Up
vX.XX.XX.XXX
Secondary CPM Power Up where
X.XX.XXX.XXX is the software version inform-
ation.
001000[#0000|NRR0200*
vX.XX.XXX.XXX*]
SG -01-000-0000-NRR0200-Secondary CPM Power Up
vX.XX.XXX.XXX
License key entered is incorrect – ss will be C1
(primary CPM or C2 (Secondary CPM)
001000[#0000|NUXss00]
SG -01-000-0000-NUXss00-Invalid License Key
License key entered is correct – but there is insuf-
ficient EMMC memory – ss will be C1 (primary
CPM or C2 (Secondary CPM)
001000[#0000|NUXss01]
SG -01-000-0000-NUXss01– Insufficient Non-Volatile memory
License key entered is correct – but there is insuf-
ficient DDR3 memory – ss will be C1 (primary CPM
or C2 (Secondary CPM)
001000[#0000|NUXss02]
SG -01-000-0000-NUXss02– Insufficient Volatile memory
An AHS Entry has been deleted from the table -
where XXXXXXXXXX is the phone number for
the AHS entry
No Automation Message
SG -01-000-0000--AHS Entry Deleted XXXXXXXXXX
Get AHS Table
No Automation Message
SG -01-000-0000--GET AHS Table
SET AHS TABLE
No Automation Message
SG -01-000-0000--SET AHS Table
SET AHS ENTRY
No Automation Message
SG -01-000-0000--SET AHS Entry
AHS FLASH START(Primary CPM)
No Automation Message
SG -01-000-0000--AHS Flash Start (Primary)
AHS FLASH START(Secondary CPM)
No Automation Message
SG -01-000-0000--AHS Flash Start (Secondary)
AHS FLASH DONE(Primary CPM)
No Automation Message
SG -01-000-0000--AHS Flash Done (Primary)
AHS FLASH DONE(Secondary CPM)
No Automation Message
SG -01-000-0000--AHS Flash Done (Secondary)
RESET BY CONSOLE
No Automation Message
SG -01-000-0000--RESET by CONSOLE
RESET BY User
No Automation Message
SG -01-000-0000--RESET by USER
Invalid Password to Enter LCD Program
Where xx is the user number, and NAME is the pro-
grammed user label string
001000[#0000|NLX00xx]
SG -01-000-0000-NLX00XX-User: NAME Local Programming
Denied
Local Programming Begin via LCD
Where xx is the user number, and NAME is the pro-
grammed user label string
001000[#0000|NLB00xx]
SG -01-000-0000-NLB00XX-User: NAME Local Programming
Begins
Local Programming End via LCD
Where xx is the user number, and NAME is the pro-
grammed user label string
001000[#0000|NLD00xx]
SG -01-000-0000-NLD00XX-User: NAME Local Programming
Ended
Manual Mode Message ACK By User NAME -
Name is the programmed user label string and
{printer message} is the message that was acknow-
ledged
No Automation Message
SG -01-sss-AAAA--01/00-0000- {Printer Message} -Acknow-
ledged by User NAME
CPM 1 Auxiliary CPU Failure
001000[#0000|NYX0003] SG -01-000-0000-NYX0003-Primary CPM Auxiliary CPU Failure
CPM 2 Auxiliary CPU Failure
001000[#0000|NYX0004]
SG -01-000-0000-NYX0004-Secondary CPM Auxiliary CPU Fail-
ure
CPM 1 Auxiliary CPU Restore NOTE – for V1.10
CPM this message may not be required as the trouble
condition is currently latching
001000[#0000|NYZ0003]
SG -01-000-0000-NYZ0003-Primary CPM 1 Auxiliary CPU