ELECTRONIC CONTROL PANEL

SET CLOCK

+

-

REGEN

NEXT

6:00

SET

ALARM BUZZER START

SET CLOCK

+

-

REGEN

NEXT

22:00

SET

ALARM BUZZER END

COMPLETION: 

Similarly, set the time when the alarm is to 

switch off.

Pressing  the  button  „NEXT”  causes  going  to  the  next 
parameter. You can go back to the previous step anytime, 
by pressing the button „REGEN”.

START-UP: 

SETTING  THE  TIME  (MINUTES):  Set  proper 

figure  of  „minutes”  by  pressing  the  buttons  „+”  or  „-”. 
Pressing  the  button  „NEXT”  causes  going  to  the  next 
parameter. You can go back to the previous step anytime, 
by pressing the button „REGEN”.

1

2

Step  11:  Setting  the  display  operation  -  By  pressing  the 
buttons „+” or „-” set the mode of the display operation.

OFF mode - if the user does not take any action, the display 
switches off after several minutes.
ON mode - causes that the display is switched on all the 
time.

You can go back to the previous step anytime, by pressing 
the button „REGEN”. Pressing the button „NEXT” causes 
the return to the main display.

SET CLOCK

+

-

REGEN

NEXT

OFF

SET

LIGHT NORMALLY

RETURN TO THE 

MAIN DISPLAY

During the operation, the controller may show one of the 
five screens. By pressing the button „NEXT” you can switch 
over between the alternative screens.

The first screen always indicates the current time. 

The  second  screen  indicates  the  amount  of  water 
expressed in litres per minute, which has flown through 
(has been filtered) by the system.

The  third  screen  informs  whether  the  holiday  mode  is 
activated  (the  holiday  mode  may  be  activated  or 
deactivated  from  this  level).  The  holiday  mode  is 
responsible for starting up the regeneration in case when 
the  time  regeneration  is  switched  off.  Then,  although 
sufficient  amount  of  water  does  not  flow  through  the 
system, the system goes into the regeneration mode to 
flush periodically the filter bed.

The fourth screen shows the volume of water remaining to 
the time of next regeneration

The fifth screen shows the number of days remaining to 
the time of next regeneration.

GENERAL INFORMATION

If the regeneration is initiated on a given day, the message 
„REGENERATION TODAY” appears on the screen.

SET CLOCK

+

-

REGEN

NEXT

REGENERATION TODAY

LPM 3250

16:23

WED

At  the  moment  the  system  goes  into  the  regeneration 
mode, the screen displays the information on the current 
stage of the regeneration, as well as the amount of time 
remaining to its completion.

REGENERATION MODE

SET CLOCK

+

-

REGEN

NEXT

8

SET

BACKWASH-AIR

10%

 SEK

Содержание OXYLINE

Страница 1: ...Installation Manual www pavirani com...

Страница 2: ...n 5 6 Commissioning 7 8 Electronic control panel 9 13 Maintenance 14 15 For future reference fill in the following data EN INSTALLATION RECORD Serial number Model Iron Fe content inlet Manganese Mn co...

Страница 3: ...use whendamaged Use a hand truck to transport the appliance To prevent accident or injury do not hoist the appliance over your shoulder Donotlaytheapplianceonitsside Keep these Instructions in a safe...

Страница 4: ...o a power outlet which is installed in a dry location with the proper rating and over current protection OPERATING CONDITIONS AND REQUIREMENTS PREPARATION OF THE SYSTEM FOR INSTALLATION 4 Before insta...

Страница 5: ...e of repairs It allows to turn off the water to the appliance while maintaining untreated water supply to the user INLET OUTLET WITH FACTORY BYPASS optional 2 3 4 1 1 mains water supply untreated wate...

Страница 6: ...ecommend the use of a stand pipe with air trap To prevent backflow from the drainage system into the appliance always make sure to have an air gap between the end of the drain line and the drainage sy...

Страница 7: ...y Step 2 Raise the ratchets with special attention see photo Pull out the element on which the controller is installedbypushingitgently NOTE YOU MUST BE PARTICULARLY CAREFUL NOT TO BREAK THE FASTENING...

Страница 8: ...faucet nearby the appliance and let the water run for a few minutes until all air is purged and all foreign material that may have resultedfromtheinstallationiswashedout closethetap STEP 5 Gently pres...

Страница 9: ...R SET 16 00 Step 3 SETTING THE TIME MINUTES Set proper figure of minutes by pressing the buttons or Pressing the button NEXT causes going to the next parameter You can go back to the previous step any...

Страница 10: ...LISH With the buttons or you can change the language The user may select the following language versions English German French Spanish and Italian Press the button REGEN if you want to finish or NEXT...

Страница 11: ...ption the system will additionally inform you with a buzzer about the planned service CUSTOM ALARM DISPLAY in this option the system will not additionally inform you with a buzzer about the plannedser...

Страница 12: ...fivescreens Bypressingthebutton NEXT youcanswitch overbetweenthealternativescreens Thefirstscreenalwaysindicatesthecurrenttime The second screen indicates the amount of water expressed in litres per...

Страница 13: ...T MODE To initiate the regeneration immediately you should press and hold the button REGEN The system immediately goes into the regeneration mode NOTE THISPROCESSCANNOTBECANCELLED In case the system i...

Страница 14: ...let valve to appliance is CLOSED 2 outlet valve from appliance is OPEN 1 1 2 3 SERVICE POSITION 1 1 bypass valve is CLOSED 2 inlet valve to appliance is OPEN 3 outlet valve from appliance is OPEN WITH...

Страница 15: ...r are alternately flashing on the display record the number and contact the dealer for help This indicates that the control valvewasnotabletofunctionproperly ERROR Correct battery orientation When rep...

Отзывы: