COMMISSIONING
Step 6. Place the front panel and then connect the
transformer to power outlet.
Step 5. Plug in the element on which the controller is
installed. Push the element gently until you can hear a
characteristic „click”.
NOTE! YOU MUST BE PARTICULARLY CAREFUL NOT TO
BREAK THE FASTENINGS AND NOT TO DAMAGE THE
DISPLAY.
STEP
1.
Make sure the bypass system is in 'bypass'
position.
STEP
2.
Make sure the electronic controller of the
appliance is in service mode.
PRESSURIZING
STEP
3.
Open the mains water supply.
STEP
4.
Open a cold treated water faucet nearby the
appliance and let the water run for a few minutes until all
air is purged and all foreign material that may have
resulted from the installation is washed out; close the tap.
STEP
5.
Gently pressurize the appliance, by putting it into
service:
f
actory bypass:
1
.
open the 'outlet' valve;
2
.
slowly open the 'inlet' valve.
3
-valve bypass:
1
.
close the 'bypass' valve;
2
.
open the 'outlet' valve;
3
.
slowly open the 'inlet' valve.
STEP 6.
After 2-3 minutes, open a cold treated water
faucet nearby the appliance and let the water run for a few
minutes until all air is purged from the installation and the
resin bed is rinsed (it is normal for the rinse water to show
some discoloration!); close the tap.
STEP 7.
Check the appliance and all hydraulic connections
for leaks.
8
Содержание OXYLINE
Страница 1: ...Installation Manual www pavirani com...