COMMISSIONING

Step  6.  Place  the  front  panel  and  then  connect  the 
transformer to power outlet.

Step  5.  Plug  in  the  element  on  which  the  controller  is 
installed.  Push  the  element  gently  until  you  can  hear  a 
characteristic „click”. 

NOTE!  YOU  MUST  BE  PARTICULARLY  CAREFUL  NOT  TO 
BREAK  THE  FASTENINGS  AND  NOT  TO  DAMAGE  THE 
DISPLAY. 

STEP 

1.

 

Make  sure  the  bypass  system  is  in  'bypass' 

position.

STEP 

2.

 

Make  sure  the  electronic  controller  of  the 

appliance is in service mode. 

PRESSURIZING

STEP 

3.

 

Open the mains water supply.

STEP 

4.

 

Open  a  cold  treated  water  faucet  nearby  the 

appliance and let the water run for a few minutes until all 
air  is  purged  and  all  foreign  material  that  may  have 
resulted from the installation is washed out; close the tap.

STEP 

5.

 

Gently pressurize the appliance, by putting it into 

service:

f

actory bypass:

1

.

 

open the 'outlet' valve;

2

.

 

slowly open the 'inlet' valve. 

3

-valve bypass:

1

.

 

close the 'bypass' valve;

2

.

 

open the 'outlet' valve;

3

.

 

slowly open the 'inlet' valve.

STEP  6. 

After  2-3  minutes,  open  a  cold  treated  water 

faucet nearby the appliance and let the water run for a few 
minutes until all air is purged from the installation and the 
resin bed is rinsed (it is normal for the rinse water to show 
some discoloration!); close the tap.

STEP 7. 

Check the appliance and all hydraulic connections 

for leaks.

8

Содержание OXYLINE

Страница 1: ...Installation Manual www pavirani com...

Страница 2: ...n 5 6 Commissioning 7 8 Electronic control panel 9 13 Maintenance 14 15 For future reference fill in the following data EN INSTALLATION RECORD Serial number Model Iron Fe content inlet Manganese Mn co...

Страница 3: ...use whendamaged Use a hand truck to transport the appliance To prevent accident or injury do not hoist the appliance over your shoulder Donotlaytheapplianceonitsside Keep these Instructions in a safe...

Страница 4: ...o a power outlet which is installed in a dry location with the proper rating and over current protection OPERATING CONDITIONS AND REQUIREMENTS PREPARATION OF THE SYSTEM FOR INSTALLATION 4 Before insta...

Страница 5: ...e of repairs It allows to turn off the water to the appliance while maintaining untreated water supply to the user INLET OUTLET WITH FACTORY BYPASS optional 2 3 4 1 1 mains water supply untreated wate...

Страница 6: ...ecommend the use of a stand pipe with air trap To prevent backflow from the drainage system into the appliance always make sure to have an air gap between the end of the drain line and the drainage sy...

Страница 7: ...y Step 2 Raise the ratchets with special attention see photo Pull out the element on which the controller is installedbypushingitgently NOTE YOU MUST BE PARTICULARLY CAREFUL NOT TO BREAK THE FASTENING...

Страница 8: ...faucet nearby the appliance and let the water run for a few minutes until all air is purged and all foreign material that may have resultedfromtheinstallationiswashedout closethetap STEP 5 Gently pres...

Страница 9: ...R SET 16 00 Step 3 SETTING THE TIME MINUTES Set proper figure of minutes by pressing the buttons or Pressing the button NEXT causes going to the next parameter You can go back to the previous step any...

Страница 10: ...LISH With the buttons or you can change the language The user may select the following language versions English German French Spanish and Italian Press the button REGEN if you want to finish or NEXT...

Страница 11: ...ption the system will additionally inform you with a buzzer about the planned service CUSTOM ALARM DISPLAY in this option the system will not additionally inform you with a buzzer about the plannedser...

Страница 12: ...fivescreens Bypressingthebutton NEXT youcanswitch overbetweenthealternativescreens Thefirstscreenalwaysindicatesthecurrenttime The second screen indicates the amount of water expressed in litres per...

Страница 13: ...T MODE To initiate the regeneration immediately you should press and hold the button REGEN The system immediately goes into the regeneration mode NOTE THISPROCESSCANNOTBECANCELLED In case the system i...

Страница 14: ...let valve to appliance is CLOSED 2 outlet valve from appliance is OPEN 1 1 2 3 SERVICE POSITION 1 1 bypass valve is CLOSED 2 inlet valve to appliance is OPEN 3 outlet valve from appliance is OPEN WITH...

Страница 15: ...r are alternately flashing on the display record the number and contact the dealer for help This indicates that the control valvewasnotabletofunctionproperly ERROR Correct battery orientation When rep...

Отзывы: