Step  3:  Setting  the  time  regeneration  -  As  standard  the 
producer  set  the  interval  between  the  regenerations 
every  4  days.  If  this  parameter  is  set  as  „OFF”,  the 
regeneration will take place in the volume mode i.e. it will 
be initiated when proper amount of water in m3 has flown 
through the system. 

If the daily regeneration mode is set at the position „OFF”, 
then the system will operate in the volume mode, but if 
the time regeneration parameter is set up (range 1 - 28), 
then  the  system  will  operate  in  the  volume  and  time 
mode.  

With  the  buttons  „+”  or  „-”  set  the  daily  regeneration 
mode (recommended 4 days).

NOTE!  Based  on  the  observation  and  the  result  of  the 
water test done, the user may increase the time interval 
between  the  regenerations.  In  order  to  adjust  the 
appliance as precisely as possible to the flushing cycles, 
we  suggest  also  using  the  readouts  from  the  pressure 
gauges installed on the water inlet and outlet from the 
appliance.  The  difference  in  the  values,  (the  pressure 
drop at the second pressure gauge by 0.5 bars or more), 
informs  when  the  next  regeneration  of  the  appliance 
should occur.

Press the button „NEXT” to go to the next parameter. Press 
the button „REGEN” if you want to go back to the previous 
parameter.

Step 2: SETTING THE LANGUAGE - the display shows that it 
operates in English version „ENGLISH”. With the buttons 
„+”  or  „-”  you  can  change  the  language.  The  user  may 
select the following language versions: English, German, 
French, Spanish and Italian. Press the button „REGEN” if 
you want to finish, or „NEXT” if you want to go to the next 
parameter.

SET CLOCK

+

-

REGEN

NEXT

DISPLAY

SET

ENGLISH

SET CLOCK

+

-

REGEN

NEXT

6

SET

DAYS BETWEEN REGEN

Step 4: Setting the regeneration time (HOUR) - As standard 
the producer set the regeneration at 2:00. At that time the 
appliance  regeneration  cycles  are  to  be  initiated.  By 
means of the buttons „+” or „-” you can set by yourself the 
time at which the system is to initiate the regeneration 
process. We suggest to leave the regeneration time in the 
standard mode, because the water demand is smaller at 
night, and in most cases the electricity cost tariff is lower.
Press  the  button  „NEXT”,  to  go  to  the  next  parameter. 
Press the button „REGEN” if you want to go back to the 
previous parameter.

SET CLOCK

+

-

REGEN

NEXT

2:00

SET

REGEN TIME HOUR

Step 6A: Service alarm - By pressing the buttons „+” or „-” 

3

set the service alarm in m .

If  you  want  your  appliance  to  remind  you  about  the 
planned service works after the proper amount of water 
has flown through, switch on the service message (range 

3

100 - 50000 m ). The producer recommends to leave this 
option as switched off - OFF mode.

Step  5:  Setting  the  regeneration  time  (MINUTES)  -  By 
pressing  the  buttons  „+”  or  „-”,  set  the  minutes 
analogically.
Press the button „NEXT” to go to the next parameter. Press 
the button „REGEN”, if you want to go back to the previous 
parameter. 

SET CLOCK

+

-

REGEN

NEXT

OFF

SET

3

m

SERVICE ALARM

Содержание OXYLINE

Страница 1: ...Installation Manual www pavirani com...

Страница 2: ...n 5 6 Commissioning 7 8 Electronic control panel 9 13 Maintenance 14 15 For future reference fill in the following data EN INSTALLATION RECORD Serial number Model Iron Fe content inlet Manganese Mn co...

Страница 3: ...use whendamaged Use a hand truck to transport the appliance To prevent accident or injury do not hoist the appliance over your shoulder Donotlaytheapplianceonitsside Keep these Instructions in a safe...

Страница 4: ...o a power outlet which is installed in a dry location with the proper rating and over current protection OPERATING CONDITIONS AND REQUIREMENTS PREPARATION OF THE SYSTEM FOR INSTALLATION 4 Before insta...

Страница 5: ...e of repairs It allows to turn off the water to the appliance while maintaining untreated water supply to the user INLET OUTLET WITH FACTORY BYPASS optional 2 3 4 1 1 mains water supply untreated wate...

Страница 6: ...ecommend the use of a stand pipe with air trap To prevent backflow from the drainage system into the appliance always make sure to have an air gap between the end of the drain line and the drainage sy...

Страница 7: ...y Step 2 Raise the ratchets with special attention see photo Pull out the element on which the controller is installedbypushingitgently NOTE YOU MUST BE PARTICULARLY CAREFUL NOT TO BREAK THE FASTENING...

Страница 8: ...faucet nearby the appliance and let the water run for a few minutes until all air is purged and all foreign material that may have resultedfromtheinstallationiswashedout closethetap STEP 5 Gently pres...

Страница 9: ...R SET 16 00 Step 3 SETTING THE TIME MINUTES Set proper figure of minutes by pressing the buttons or Pressing the button NEXT causes going to the next parameter You can go back to the previous step any...

Страница 10: ...LISH With the buttons or you can change the language The user may select the following language versions English German French Spanish and Italian Press the button REGEN if you want to finish or NEXT...

Страница 11: ...ption the system will additionally inform you with a buzzer about the planned service CUSTOM ALARM DISPLAY in this option the system will not additionally inform you with a buzzer about the plannedser...

Страница 12: ...fivescreens Bypressingthebutton NEXT youcanswitch overbetweenthealternativescreens Thefirstscreenalwaysindicatesthecurrenttime The second screen indicates the amount of water expressed in litres per...

Страница 13: ...T MODE To initiate the regeneration immediately you should press and hold the button REGEN The system immediately goes into the regeneration mode NOTE THISPROCESSCANNOTBECANCELLED In case the system i...

Страница 14: ...let valve to appliance is CLOSED 2 outlet valve from appliance is OPEN 1 1 2 3 SERVICE POSITION 1 1 bypass valve is CLOSED 2 inlet valve to appliance is OPEN 3 outlet valve from appliance is OPEN WITH...

Страница 15: ...r are alternately flashing on the display record the number and contact the dealer for help This indicates that the control valvewasnotabletofunctionproperly ERROR Correct battery orientation When rep...

Отзывы: