1) Can be increased or decreased by +10% or -10% using ‘’CFM adjust’’ option on the control board.
2) Calculated on the basis of Norm C22.2 No.236.
Power second stage (Kw)
15
18
20
23
27
Power first stage (Kw)
10
9
10
13
17
Net capacity second stage (BTU/h)
51180
61420
68240
78480
92130
Heating temperature rise, second stage heating (F)
1
58
62
62
62
60
Heating temperature rise, first stage heating (F)
1
78
62
62
70
75
Volts - Hertz - Phase
Electrical element #1 (Kw)
5
4
5
4
4
Electrical element #2 (Kw)
5
5
5
5
5
Electrical element #3 (Kw)
5
4
5
4
4
Electrical element #4 (Kw)
5
5
5
4
Electrical element #5 (Kw)
5
5
Electrical element #6 (Kw)
5
Blower motor Consumption (Amp)
4,3
4,3
4,3
9,1
9,1
Heating Elements Consumption (Amp)
61
74
82
94
111
Total Consumption (Amp)
65,3
78,3
86,3
103,1
120,1
Circuit amperage (wire sizing)
2
82
98
108
130
150
Maximum size circuit breaker (Amp)
2
90
100
110
150
150
Motor (HP) / Type
Blower size
Overall dimensions (width x depth x height)
Supply
Return
Filter quantity and size
Shipping weight
Maximum cooling capacity
SPECIFICATIONS, FEM ELECTRIC FURNACE WITH ECM MOTOR
RATINGS AND PERFORMANCE
FEM
xx
-E230V1M-A
FEM
xx
-E230V2M-A
ELECTRICAL SYSTEM
2 wires 240 - 60 - 1
BLOWER DATA
1/2 HP / ECM 2.3
1 HP / ECM 2.3
G10-8 or 100-8R
GT12010 or 120-10T
GENERAL INFORMATION
20" x 20" x 36.5"
3 tons
5tons
15" x 18"
19" x 19"
(1) 20" x 20"
48 Kg / 105 lbs
TABLE 2
Technical Specifications
14
Содержание FEM15-E230V1M-A
Страница 12: ...12 FIGURE 9 Diagramme électrique ...
Страница 17: ...17 COMPOSANTES ET PIÈCES DE REMPLACEMENT ...
Страница 18: ...18 LISTE DE PIÈCES Vue explosée B50081 Rev B ...
Страница 31: ...12 FIGURE 9 Electrical Diagram ...
Страница 36: ...17 COMPONENTS AND REPLACEMENT PARTS ...
Страница 37: ...18 PARTS LIST Exploded view B50081 Rev B ...