background image

FORM NO. G11-502 REV. 1

Supersedes Form No. G11-502

GAS FURNACES

RGTC- SERIES

Models with Input Rates 
from 45,000 to 105,000 BTU/HR
[13.19 to 30.77 kW]

(All Models up to 95% A.F.U.E.

)

CLASSIC

®

90 PLUS

95% A.F.U.E.
DOWNFLOW/
HORIZONTAL
GAS FURNACES

The Rheem Classic

®

90 Plus High Efficiency line of down-

flow/horizontal gas furnaces are designed for utility rooms,
closets, alcoves, attics or crawl spaces. The RGTC is
shipped in the downflow configuration and is easily con-
verted for horizontal left-hand airflow applications.

The design is certified by CSA.

Features

Heat exchanger is constructed of all stainless steel for
maximum corrosion resistance and thermal fatigue
reliability.

Low profile “34 inch” design is lighter and easier to han-
dle and leaves room for optional accessories.

Top electrical connections, left or right gas and conden-
sate drainage connections on downflow models.

Condensate drain for horizontal application provided
standard.

Integrated control board manages all operational func-
tions and provides hookups for humidifier and electronic
air cleaner.

An insulated blower compartment, a slow-opening gas
valve and a specially designed inducer system make it
one of the quietest furnaces on the market today.

Pre-paint galvanized steel cabinet.

Molded permanent filters.

Optional indoor or outdoor combustion air.

Transformer and control fuse protection.

Control board diagnostics.

A variety of cooling coils and plenums designed to use with
the Classic

®

90 Plus gas furnaces are available as optional

accessories for air conditioning models.

A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
of Energy test procedures.

“Visit www.Rheem.com

for complete details.”

Содержание CLASSIC 90 PLUS

Страница 1: ...for optional accessories Top electrical connections left or right gas and conden sate drainage connections on downflow models Condensate drain for horizontal application provided standard Integrated c...

Страница 2: ...cooling applications transformer direct drive multi speed blower motor Please note a thermostat is not included as standard equipment OPTIONAL EQUIPMENT NOTE Furnace is not listed for use with fuels...

Страница 3: ...XT STATIC PRESSURE IN W C kPa 10 025 12 029 12 029 15 037 20 049 RATED EXT STATIC PRESSURE IN W C kPa 50 124 50 124 50 124 50 124 50 124 HEATING CFM 2 W C E S P L s 866 409 1122 530 1516 716 1698 802...

Страница 4: ...D E F LEFT SIDE MINIMUM CLEARANCE IN mm SHIP WGTS kg RIGHT SIDE BACK TOP FRONT VENT 04 171 2 445 1611 32 415 155 8 397 2 51 165 8 422 137 8 352 0 0 0 1 25 2 51 0 123 56 06 171 2 445 1611 32 415 155 8...

Страница 5: ...Horizontal furnace may be installed for horizontal left hand air supply ONLY The condensate trap provided for horizontal application must be installed in the field beneath the unit as directed in the...

Страница 6: ...8 632 1555 734 1743 823 1097 518 1309 618 1516 716 1696 801 1068 504 1280 604 1477 698 1649 779 1036 489 1253 592 1440 680 1604 757 1003 473 1225 579 1402 662 1559 736 963 455 1185 560 1349 637 1501 7...

Страница 7: ...Rheem Heating Cooling and Water Heating 7 NOTES...

Страница 8: ...ate Provincial and Local codes regulations and practices Rheem Heating Cooling and Water Heating P O Box 17010 Fort Smith AR 72917 In keeping with its policy of continuous progress and product improve...

Отзывы: