FILTER RACK FILTER SIZES* INCHES [mm]

MODEL RGTC-

RXGF-CC

04

(2) 12 x 20 [305 x 508]

06

(2) 12 x 20 [305 x 508]

07

(2) 12 x 20 [305 x 508]

09

(2) 12 x 20 [305 x 508]

10

(2) 14 x 20 [356 x 508]

FURNACE

WIDTH

IN. [mm]

PLENUM

WIDTH

IN. [mm]

PLENUM ADAPTER

DOWNFLOW

COIL

PLENUM

17

1

/

2

[445]

16

1

/

4

[413]

RXAA-C186

RXAL-B16BU

17

1

/

2

[445]

20

1

/

4

[514]

RXAA-C173

RXAL-B20BU

17

1

/

2

[445]

21

5

/

8

[549]

RXAA-C187

RXAL-B21BU

17

1

/

2

[445]

25

1

/

4

[641]

RXAA-C174

RXAL-B25BU

21

1

/

2

[533]

25

1

/

4

[641]

RXAA-C175

RXAL-B25BU

21

1

/

2

[533]

22

1

/

4

[565]

RXAA-C176

RXAL-B22BU

24

1

/

2

[622]

25

1

/

4

[641]

RXAA-C177

RXAL-B25BU

24

1

/

2

[622]

21

5

/

8

[549]

RXAA-C187

RXAL-B21BU

21

1

/

2

[533]

21

5

/

8

[549]

RXAA-C188

RXAL-B21BU

MODEL

RGTC-

BLOWER

SIZE

IN. [mm]

MOTOR

H.P.

[W]

BLOWER

SPEED

CFM [L/s] AIR DELIVERY

EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPa]

09

12 x 11

[305 x 279]

3/4

[559]

LOW*

MED-L0

MED-HI

HIGH

1213 [573]
1504 [710]

1734 [819]

2111 [997]

1196 [565]
1474 [696]

1698 [802]

2059 [972]

1179 [557]
1443 [681]

1662 [785]

2007 [948]

1158 [547]
1415 [668]

1621 [766]

1946 [919]

1136 [536]
1387 [655]

1579 [746]

1885 [890]

1108 [523]
1348 [637]

1526 [721]

1821 [860]

0.1 [.02]

0.2 [.05]

0.3 [.07]

0.4 [.10]

0.5 [.12]

0.6 [.15]

0.7 [.17]

04

11 x 7

[279 x 178]

1/2

[373]

LOW

MED-LO

MED-HI

HIGH

794 [375]

890 [420]

1110 [524]
1383 [653]

765 [361]

866 [409]

1084 [512]
1350 [638]

735 [347]

842 [398]

1057 [499]
1317 [622]

704 [332]

811 [383]

1023 [483]
1274 [602]

672 [317]

779 [368]

989 [467]

1230 [581]

633 [299]

750 [354]

946 [447]

1171 [553]

594 [281]

721 [341]

902 [426]

1112 [525]

06

11 x 7

[279 x 178]

1/2

[373]

LOW*

MED-L0

MED-HI

HIGH

816 [385]
924 [436]

1164 [550]

1409 [665]

792 [374]
895 [423]

1122 [530]

1367 [646]

767 [362]
866 [409]

1080 [510]

1325 [626]

739 [349]
832 [393]

1044 [493]

1284 [606]

711 [336]
798 [377]

1008 [476]

1242 [586]

686 [324]
754 [356]

966 [456]

1195 [564]

661 [312]
710 [335]

923 [436]

1148 [542]

07

11 x 10

[279 x 254]

1/2

[373]

LOW*

MED-L0

MED-HI

HIGH

1126 [532]
1338 [632]

1555 [734]

1743 [823]

1097 [518]
1309 [618]

1516 [716]

1696 [801]

1068 [504]
1280 [604]

1477 [698]

1649 [779]

1036 [489]
1253 [592]

1440 [680]

1604 [757]

1003 [473]
1225 [579]

1402 [662]

1559 [736]

963 [455]

1185 [560]

1349 [637]

1501 [709]

923 [436]

1145 [541]

1295 [612]

1442 [681]

1079 [510]
1308 [618]

1472 [695]

1756 [829]

10

11 x 10

[279 x 254]

3/4

[559]

LOW*

MED-L0

MED-HI

HIGH

1324 [625]
1617 [764]

1842 [870]

2204 [1041]

1309 [618]
1505 [753]

1812 [856]

2153 [1017]

1294 [611]
1573 [743]

1781 [841]

2102 [993]

1272 [601]
1533 [724]

1728 [816]

2040 [963]

1250 [590]
1493 [705]

1674 [791]

1977 [934]

1221 [577]
1448 [684]

1619 [765]

1905 [900]

1191 [562]
1402 [662]

1564 [739]

1833 [866]

ACCESSORIES—DOWNFLOW

PLENUM DATA FOR “A” COILS

Plenum adapters are required in some instances for use on downflow applications
when plenum and furnace size do not match.

VENT TERMINATION KITS CONCENTRIC: HORIZONTAL/

VERTICAL =

RXGY-E03A 

(US & Canadian Installations)

HORIZONTAL TWO PIPE: 

RXGY-D02, RXGY-D03, RXGY-D04 

(US Installations)

RXGY-D02A, RXGY-D03A, RXGY-D04A 

(Canadian Installations)

RXGY-G02 

(US Only)

CONDENSATE PUMP KIT: 

RXGY-B01

NEUTRALIZER KIT: 

RXGY-A01

COMBUSTIBLE FLOOR BASE: 

RXGC-B17
RXGC-B21
RXGC-B24

EXTERNAL FILTER RACK:

RXGF-CC

*Filter racks are shipped without filters.

Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter.

[

] Designates Metric Conversions

BLOWER PERFORMANCE DATA—RGTC MODELS

NOTE:

Recommended heating blower speeds are in bold.

*Not allowed for heating speed tap.

NOTE:

CFM values represent furnace-only airflow ratings.

NOTE: See Form Number C11-206 for MultiFlex

®

coil data.

FOSSIL FUEL KIT: 

RXPF-F01

RXPF-F02 (TVA)

6

Rheem Heating, Cooling and Water Heating

FOR HIGH ALTITUDES

NOTE: 

For Canadian installations only, an optional derate (manifold gas
pressure reduction) method may be used to adjust the furnace for
altitude. See Installation Instructions for more information. This
optional method may 

NOT

be used for U.S. installations.

FOR LEFT SIDE (ALTERNATE) CONDENSATE
DRAIN KIT: 

RXGY-H01 (All Models)

Содержание CLASSIC 90 PLUS

Страница 1: ...for optional accessories Top electrical connections left or right gas and conden sate drainage connections on downflow models Condensate drain for horizontal application provided standard Integrated c...

Страница 2: ...cooling applications transformer direct drive multi speed blower motor Please note a thermostat is not included as standard equipment OPTIONAL EQUIPMENT NOTE Furnace is not listed for use with fuels...

Страница 3: ...XT STATIC PRESSURE IN W C kPa 10 025 12 029 12 029 15 037 20 049 RATED EXT STATIC PRESSURE IN W C kPa 50 124 50 124 50 124 50 124 50 124 HEATING CFM 2 W C E S P L s 866 409 1122 530 1516 716 1698 802...

Страница 4: ...D E F LEFT SIDE MINIMUM CLEARANCE IN mm SHIP WGTS kg RIGHT SIDE BACK TOP FRONT VENT 04 171 2 445 1611 32 415 155 8 397 2 51 165 8 422 137 8 352 0 0 0 1 25 2 51 0 123 56 06 171 2 445 1611 32 415 155 8...

Страница 5: ...Horizontal furnace may be installed for horizontal left hand air supply ONLY The condensate trap provided for horizontal application must be installed in the field beneath the unit as directed in the...

Страница 6: ...8 632 1555 734 1743 823 1097 518 1309 618 1516 716 1696 801 1068 504 1280 604 1477 698 1649 779 1036 489 1253 592 1440 680 1604 757 1003 473 1225 579 1402 662 1559 736 963 455 1185 560 1349 637 1501 7...

Страница 7: ...Rheem Heating Cooling and Water Heating 7 NOTES...

Страница 8: ...ate Provincial and Local codes regulations and practices Rheem Heating Cooling and Water Heating P O Box 17010 Fort Smith AR 72917 In keeping with its policy of continuous progress and product improve...

Отзывы: