background image

TECHNICAL GUIDE

AFFINITY 

MODELS: PC9*UP

GAS-FIRED
CONDENSING / HIGH EFFICIENCY
UPFLOW MODULATING FURNACES
WITH ECM MOTORS

NATURAL GAS
60 - 120 MBH INPUT

Due to continuous product improvement, specifications
are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at 
www.gamanet.org.

EFFICIENCY
RATING
CERTIFIED

ISO 9001

Certified Quality

Management System

246813-YTG-D-0108

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.

WARRANTY

Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
5-year limited parts warranty.

FEATURES

• Modulating heating operation includes:

- Modulating gas valve
- Modulating inducer operation

• Provides increased comfort level & very quiet unit opera-

tion

• Compact, easy to install, ideal height 40" cabinet

• Blower-off delay for cooling SEER improvement.

• Easy to connect power/control wiring.

• Built-in, high level self diagnostics with fault code display.

• Low unit amp requirement for easy replacement applica-

tion.

• Integrated control module for reliable, economical opera-

tion.

• May be installed as either two-pipe (direct vent) or single 

pipe vent (using indoor combustion air)

• Top intake & vent connection allows installation in narrow 

locations.

• Electronic Hot Surface Ignition saves fuel cost with 

increased dependability and reliability.

• Induced combustion system with inshot main burners for 

quiet, efficient operation.

• No special vent termination kit required.

• 100% shut off main gas valve for extra safety.

• ECM high efficiency direct drive motor with large, quiet 

blower.

• 24V, 40 VA control transformer and blower relay supplied 

for add-on cooling.

• Hi-tech tubular aluminized steel primary heat exchanger.

• Secondary (condensing) heat exchanger of 29-4C high-

grade stainless steel.

• Solid removable bottom panel allows easy application.

• Easy access from front of unit for cleaning, maintenance or 

service.

• Protection from intake, exhaust or condensate blockage.

• Insulated blower compartment for quiet operation.

Содержание PC9B12N060UP11

Страница 1: ...l appli cations 5 year limited parts warranty FEATURES Modulating heating operation includes Modulating gas valve Modulating inducer operation Provides increased comfort level very quiet unit opera tion Compact easy to install ideal height 40 cabinet Blower off delay for cooling SEER improvement Easy to connect power control wiring Built in high level self diagnostics with fault code display Low u...

Страница 2: ...WITH EXTERNAL FILTER FRAME LEFT SIDE FRONT RIGHT SIDE BOTTOM IMAGE RETURN END TOP IMAGE SUPPLY END 1 1 2 GAS PIPE ENTRY 7 8 JUNCTION BOX HOLE T STAT WIRING 7 8 K O CONDENSATE DRAIN 7 8 K O DIMENSIONS Models Nominal CFM Cabinet Size Cabinet Dimension A in B in C in D in PC9B12N060UP11 1200 B 17 1 2 16 1 4 14 1 2 8 1 2 PC9B12N080UP11 1200 B 17 1 2 16 1 4 11 8 1 2 PC9C16N080UP11 1600 C 21 19 3 4 18 8...

Страница 3: ...Maximum Input Air Temp Rise Minimum Input MBH MBH In HP Amps F F PC9B12N060UP11 60 21 57 20 11 x 8 1 2 7 7 20 40 70 20 50 PC9B12N080UP11 80 28 76 26 11 x 8 1 2 7 7 20 40 70 20 50 PC9C16N080UP11 80 28 76 26 11 x 10 3 4 9 6 20 40 70 20 50 PC9C16N100UP11 100 35 95 33 11 x 10 3 4 9 6 20 40 70 20 50 PC9C20N100UP11 100 35 95 33 11 x 11 1 12 8 20 40 70 20 50 PC9D20N120UP11 120 42 115 39 11 x 11 1 12 8 20...

Страница 4: ...age Compressor C 24 Volt Common R 24 Volt Hot Y1 Single Stage Compressor VARIABLE SPEED MODULATING FURNACE CONTROL G Fan VARIABLE SPEED MODULATING FURNACE Y Y2 Second or Full Stage Compressor HUM Dehumidification Open on Humidity Rise W Modulating Heat Part Numbers SAP Legacy 171334 031 09153 1 1 Move HUMIDISTAT jumper to YES if humidistat is to be used FL9C FC9C PC9 ID MODELS External Humidistat ...

Страница 5: ...ES if humidistat is to be used FL9C FC9C PC9 ID MODELS External Humidistat Optional Open on Humidity Rise 24VAC Humidifier Optional External Humidistat Optional Open on Humidity Rise 2 2 Part Number S1 2HU16700124 2 C 24 Volt Common R 24 Volt Hot Y First Stage Compressor Y2 Second Stage Compressor G Fan DN22C00124 THERMOSTAT W2 Second Stage Heat C 24 Volt Common R 24 Volt Hot Y1 First Stage Compre...

Страница 6: ...ermostat User Configuration Menu must be set to MLTISTG E W1 First Stage Heat 24VAC Humidifer Optional C 24 Volt Common R 24 Volt Hot Y1 Single Stage Compressor VARIABLE SPEED MODULATING FURNACE CONTROL G Fan VARIABLE SPEED MODULATING FURNACE Y Y2 Second or Full Stage Compressor HUM Dehumidification Open on Humidity Rise W Modulating Heat Part Numbers SAP Legacy 171334 031 09153 1 1 Move HUMIDISTA...

Страница 7: ... Stage Compressor VARIABLE SPEED MODULATING FURNACE CONTROL G Fan VARIABLE SPEED MODULATING FURNACE Y Y2 Second or Full Stage Compressor HUM Dehumidification Open on Humidity Rise W Modulating Heat Change FFuel jumper on the heat pump control to ON 1 Part Numbers SAP Legacy 171334 031 09153 2 2 Move HUMIDISTAT jumper to YES if humidistat is to be used Part Numbers SAP Legacy 126768 031 09137 18395...

Страница 8: ...FL9C FC9C PC9 ID MODELS YZE OD MODELS YZH H 5 H 8 C 24 Volt Common R 24 Volt Hot Y1 First Stage Compressor O Reversing Valve Energized in Cool L Malfunction Light Y2 Second Stage Compressor G Fan DN22H00124 DP22U70124 THERMOSTAT E W1 First Stage Aux Heat W2 Second Stage Aux Heat C 24 Volt Common Y First Stage Compressor O B Reversing Valve L Malfunction Light Y2 Second Stage Compressor G Fan PP32U...

Страница 9: ...1550 1050 1780 1180 B B 1610 1070 2040 1350 A A 1440 960 1620 1050 B A 1470 990 1840 1250 A C 1370 920 1560 1010 C B 1290 850 1470 940 B C 1130 790 1370 890 D B 1230 850 1460 930 C A 1050 720 1250 790 D A 1110 760 1310 810 C C 950 660 1090 690 D C PC9D20N120UP11 JUMPER SETTINGS CFM High Low COOL Tap ADJ Tap 2280 1510 A B 1860 1190 B B 2090 1370 A A 1630 1060 B A 1880 1250 A C 1620 1030 C B 1500 96...

Страница 10: ...on air to enter and exhaust to exit through single common hole CONDENSATE NEUTRALIZER KIT 1NK0301 Neutralizer cartidge has a 1 2 plastic tube fittings for installa tion in the drain line Calcium carbonate refill media is also avaiable from the Source 1 Parts p n 026 30228 000 SIDEWALL VENT TERMINATION 1HT0901 3 1HT0902 2 For use on sidewall two pipe installations only Provide a more attractive ter...

Страница 11: ...246813 YTG D 0108 Unitary Products Group 11 NOTES ...

Страница 12: ...ct to change without notice Printed in U S A 246813 YTG D 0108 Copyright by Unitary Products Group 2008 All rights reserved Supersedes 246813 YTG C 0606 Unitary 5005 Norman Products York OK Group Drive 73069 ...