background image

246813-YTG-D-0108

6

Unitary Products Group

Thermostat Chart - 

Optional Harness

AC 26C

Two

 Stage Air Conditioner – Variable Speed Modulating Furnace

TWO STAGE

AIR

CONDITIONER

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

Y2

Second Stage

Compressor

C

24 – Volt Common

Y1

First Stage Compressor

L

Malfunction Light

Y2

Second Stage

Compressor

G

Fan

*PP32U71124
*PP32U72124

THERMOSTAT

R

24 – Volt Hot

W2

Second Stage Heat

DHM

Dehumidification

HM

Humidistat

Step 1 of Thermostat User

Configuration Menu must 

be set to MLTISTG

E/W1

First Stage Heat

24VAC Humidifer

(Optional)

C

24 – Volt Common

R

24 – Volt Hot

Y1

Single Stage Compressor

VARIABLE SPEED 

MODULATING

FURNACE CONTROL

G

Fan

VARIABLE SPEED

MODULATING

FURNACE

Y/Y2

Second or Full

Stage Compressor

HUM

Dehumidification-

Open on Humidity Rise

W

Modulating Heat

 Part Numbers:

SAP   =    Legacy

171334 = 031-09153

1

1

Move HUMIDISTAT

jumper to “YES”

if humidistat is to be used. 

FL9C

FC9C

PC9

ID MODELS

Comfort Alert Interface

(two pin connector)

E2/P Switch must be in the

E2 position

Step 16 of Thermostat 

Installer Table Menu

 must be set to ON to use

Comfort Alert Features

Only applies to 

*PP32U72124

Содержание PC9B12N060UP11

Страница 1: ...l appli cations 5 year limited parts warranty FEATURES Modulating heating operation includes Modulating gas valve Modulating inducer operation Provides increased comfort level very quiet unit opera tion Compact easy to install ideal height 40 cabinet Blower off delay for cooling SEER improvement Easy to connect power control wiring Built in high level self diagnostics with fault code display Low u...

Страница 2: ...WITH EXTERNAL FILTER FRAME LEFT SIDE FRONT RIGHT SIDE BOTTOM IMAGE RETURN END TOP IMAGE SUPPLY END 1 1 2 GAS PIPE ENTRY 7 8 JUNCTION BOX HOLE T STAT WIRING 7 8 K O CONDENSATE DRAIN 7 8 K O DIMENSIONS Models Nominal CFM Cabinet Size Cabinet Dimension A in B in C in D in PC9B12N060UP11 1200 B 17 1 2 16 1 4 14 1 2 8 1 2 PC9B12N080UP11 1200 B 17 1 2 16 1 4 11 8 1 2 PC9C16N080UP11 1600 C 21 19 3 4 18 8...

Страница 3: ...Maximum Input Air Temp Rise Minimum Input MBH MBH In HP Amps F F PC9B12N060UP11 60 21 57 20 11 x 8 1 2 7 7 20 40 70 20 50 PC9B12N080UP11 80 28 76 26 11 x 8 1 2 7 7 20 40 70 20 50 PC9C16N080UP11 80 28 76 26 11 x 10 3 4 9 6 20 40 70 20 50 PC9C16N100UP11 100 35 95 33 11 x 10 3 4 9 6 20 40 70 20 50 PC9C20N100UP11 100 35 95 33 11 x 11 1 12 8 20 40 70 20 50 PC9D20N120UP11 120 42 115 39 11 x 11 1 12 8 20...

Страница 4: ...age Compressor C 24 Volt Common R 24 Volt Hot Y1 Single Stage Compressor VARIABLE SPEED MODULATING FURNACE CONTROL G Fan VARIABLE SPEED MODULATING FURNACE Y Y2 Second or Full Stage Compressor HUM Dehumidification Open on Humidity Rise W Modulating Heat Part Numbers SAP Legacy 171334 031 09153 1 1 Move HUMIDISTAT jumper to YES if humidistat is to be used FL9C FC9C PC9 ID MODELS External Humidistat ...

Страница 5: ...ES if humidistat is to be used FL9C FC9C PC9 ID MODELS External Humidistat Optional Open on Humidity Rise 24VAC Humidifier Optional External Humidistat Optional Open on Humidity Rise 2 2 Part Number S1 2HU16700124 2 C 24 Volt Common R 24 Volt Hot Y First Stage Compressor Y2 Second Stage Compressor G Fan DN22C00124 THERMOSTAT W2 Second Stage Heat C 24 Volt Common R 24 Volt Hot Y1 First Stage Compre...

Страница 6: ...ermostat User Configuration Menu must be set to MLTISTG E W1 First Stage Heat 24VAC Humidifer Optional C 24 Volt Common R 24 Volt Hot Y1 Single Stage Compressor VARIABLE SPEED MODULATING FURNACE CONTROL G Fan VARIABLE SPEED MODULATING FURNACE Y Y2 Second or Full Stage Compressor HUM Dehumidification Open on Humidity Rise W Modulating Heat Part Numbers SAP Legacy 171334 031 09153 1 1 Move HUMIDISTA...

Страница 7: ... Stage Compressor VARIABLE SPEED MODULATING FURNACE CONTROL G Fan VARIABLE SPEED MODULATING FURNACE Y Y2 Second or Full Stage Compressor HUM Dehumidification Open on Humidity Rise W Modulating Heat Change FFuel jumper on the heat pump control to ON 1 Part Numbers SAP Legacy 171334 031 09153 2 2 Move HUMIDISTAT jumper to YES if humidistat is to be used Part Numbers SAP Legacy 126768 031 09137 18395...

Страница 8: ...FL9C FC9C PC9 ID MODELS YZE OD MODELS YZH H 5 H 8 C 24 Volt Common R 24 Volt Hot Y1 First Stage Compressor O Reversing Valve Energized in Cool L Malfunction Light Y2 Second Stage Compressor G Fan DN22H00124 DP22U70124 THERMOSTAT E W1 First Stage Aux Heat W2 Second Stage Aux Heat C 24 Volt Common Y First Stage Compressor O B Reversing Valve L Malfunction Light Y2 Second Stage Compressor G Fan PP32U...

Страница 9: ...1550 1050 1780 1180 B B 1610 1070 2040 1350 A A 1440 960 1620 1050 B A 1470 990 1840 1250 A C 1370 920 1560 1010 C B 1290 850 1470 940 B C 1130 790 1370 890 D B 1230 850 1460 930 C A 1050 720 1250 790 D A 1110 760 1310 810 C C 950 660 1090 690 D C PC9D20N120UP11 JUMPER SETTINGS CFM High Low COOL Tap ADJ Tap 2280 1510 A B 1860 1190 B B 2090 1370 A A 1630 1060 B A 1880 1250 A C 1620 1030 C B 1500 96...

Страница 10: ...on air to enter and exhaust to exit through single common hole CONDENSATE NEUTRALIZER KIT 1NK0301 Neutralizer cartidge has a 1 2 plastic tube fittings for installa tion in the drain line Calcium carbonate refill media is also avaiable from the Source 1 Parts p n 026 30228 000 SIDEWALL VENT TERMINATION 1HT0901 3 1HT0902 2 For use on sidewall two pipe installations only Provide a more attractive ter...

Страница 11: ...246813 YTG D 0108 Unitary Products Group 11 NOTES ...

Страница 12: ...ct to change without notice Printed in U S A 246813 YTG D 0108 Copyright by Unitary Products Group 2008 All rights reserved Supersedes 246813 YTG C 0606 Unitary 5005 Norman Products York OK Group Drive 73069 ...