background image

58CMA

Multipoise

Oil Furnace

Installation, Start-Up, and Operating Instructions

For Input Capacities of 70,000—154,000; Series 110

NOTE:

Read the entire instruction manual before starting the

installation.
This symbol

indicates a change since last issue.

INDEX

Page

SAFETY CONSIDERATIONS..................................................1-3

Dimensional Drawing ...............................................................2
Minimum Clearance to Combustibles......................................3

INTRODUCTION ..........................................................................3
LOCATION....................................................................................3

General ......................................................................................3
Location Relative to Cooling Equipment ................................3

AIR FOR COMBUSTION AND VENTILATION ...................4-5

General ......................................................................................4
Unconfined Space .....................................................................4
Confined Space......................................................................4-5

DUCT WORK RECOMMENDATIONS......................................5
VENTING ......................................................................................5

Vent System Inspection.........................................................5-6
Masonry Chimneys ...................................................................6
Factory-Built Chimneys............................................................6

OIL BURNER ................................................................................6
OIL CONNECTIONS ....................................................................6
BAROMETRIC DRAFT CONTROL ...........................................6
ELECTRICAL CONNECTIONS...............................................6-9

115-v Wiring.............................................................................6
24-v Wiring...............................................................................9
Accessories................................................................................9
Wiring Diagram.................................................................... 7-8

FILTERS ........................................................................................9
START-UP, ADJUSTMENT, AND SAFETY CHECK .........9-11

Operational Checkout ...............................................................9
Combustion Check ..............................................................9-10
Fan Adjustment Check ...........................................................10
Limit Control Check...............................................................10
For Year-Round Air Conditioning .........................................10
Heating ....................................................................................10
Cooling ....................................................................................10
Constant Blower Switch .........................................................10

MAINTENANCE....................................................................11-12

General ....................................................................................11
Oil Burner ...............................................................................11
Heat Exchanger and Flue Pipe ...............................................11
Blower Removal .....................................................................12

SAFETY CONSIDERATIONS

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR
OTHER FLAMMABLE VAPORS AND LIQ-
UIDS IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE.

DO NOT ATTEMPT TO START THE BURNER
WHEN EXCESS OIL HAS ACCUMULATED,
WHEN THE FURNACE IS FULL OF VAPOR,
OR WHEN THE COMBUSTION CHAMBER IS
VERY HOT.

For use with grade 1 or 2 fuel oil. Do not use gasoline,
crankcase oil, or any oil containing gasoline! Failure to follow
this warning could lead to sooting, fire, explosion, and/or
severe bodily harm.

Never burn garbage or paper in the heating system and never
leave rags, paper, or any flammable items around the unit.

Fig. 1—58CMA Multipoise Oil Furnace

A97247

Visit www.carrier.com

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1

4

Tab

6a 8a

PC 101

Catalog No. 535-892

Printed in U.S.A.

Form 58CMA-2SI

Pg 1

1-98

Replaces: 58CMA-1SI

Содержание OIL FURNACE 58CMA

Страница 1: ...ck 10 For Year Round Air Conditioning 10 Heating 10 Cooling 10 Constant Blower Switch 10 MAINTENANCE 11 12 General 11 Oil Burner 11 Heat Exchanger and Flue Pipe 11 Blower Removal 12 SAFETY CONSIDERATI...

Страница 2: ...nd are available from either The National Fire Protection Agency Batterymarch Park Quincy MA 02269 or The Canadian Stan dards Association 178 Rexdale Blvd Rexdale Ontario M9W 1R3 Recognize safety info...

Страница 3: ...oved subbase is used Also since flue pipe is in a down flow position Downflow Conversion Vent Guard Kit MUST be used Also read page 9 When installed in a horizontal position furnace may be suspended b...

Страница 4: ...e into consideration the overall volume of unconfined space the number of windows and ventilation openings the number of doors to the outside internal doors which can close off unconfined space and ov...

Страница 5: ...uctwork should be attached to either side bottom or side and bottom of furnace See Fig 2 for dimensions of these openings NOTE The back should not be cut out for return air The following recommendatio...

Страница 6: ...ange is fixed to burner air tube and no adjustment is required for insertion length OIL CONNECTIONS Complete instructions for installing fuel oil piping can be found in oil burner Installation Instruc...

Страница 7: ...H U M 4 5 6 N 7 2 S E A C C O N T C O O L H E A T CAPACITOR WHITE RED BLUE BLACK R99G001 ST9103 CONSTANT LOW SPEED SWITCH CIRCULATING FAN BLACK WHITE UNUSED LO ML MH HI C LEADS 1 2 3 3 H U M 4 5 6 N...

Страница 8: ...4 5 6 N 7 2 S E A C C O N T C O O L H E A T CAPACITOR WHITE RED BLUE BLACK R99G001 ST9103 CONSTANT LOW SPEED SWITCH CIRCULATING FAN BLACK WHITE UNUSED LO ML MH HI C LEADS 1 2 3 3 H U M 4 5 6 N 7 2 S E...

Страница 9: ...d set above room temperature If all of the above items have been performed set main electrical switch to ON position and burner should start When burner starts proceed to Combustion Check section Step...

Страница 10: ...ed on rating plate Failure to follow this warning could lead to severe furnace damage Adjust fan speed ACCORDING TO OIL INPUT SELECTED so that temperature rise is within rise range specified on rating...

Страница 11: ...FOR AN EXTENDED PERIOD OF TIME Step 2 Oil Burner For optimum performance oil burner nozzle should be replaced once a year Contact your service technician if you are unsure of this procedure The proce...

Страница 12: ...luding Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product theory and skills programs is available using popular video based formats and materials Al...

Отзывы: