background image

   

S

UPER

®

USER’S MANUAL

Revision 1.0

S

UPER

S

ERVER

®

6027PR-HC1R

6027PR-HC1TR

6027PR-HC1FR

Содержание SuperServer 6027PR-HC1FR

Страница 1: ...SUPER USER S MANUAL Revision 1 0 SUPERSERVER 6027PR HC1R 6027PR HC1TR 6027PR HC1FR...

Страница 2: ...any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits...

Страница 3: ...s and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com Product safety info http super dev about...

Страница 4: ...4 Cooling System 1 4 Air Shrouds 1 4 Mounting Rails 1 4 1 4 Advanced Power Management 1 5 Intel Intelligent Power Node Manager 1 5 Manageability Engine ME 1 5 1 5 2U Twin2 System Notes 1 7 Nodes 1 7 S...

Страница 5: ...er Supply LEDs 3 4 Chapter 4 Standardized Warning Statements for AC Systems 4 1 About Standardized Warning Statements 4 1 Warning Definition 4 1 Installation Instructions 4 4 Circuit Breaker 4 5 Power...

Страница 6: ...ftware 5 25 SuperDoctor 5 5 26 5 13 Serverboard Battery 5 28 Chapter 6 Advanced Chassis Setup 6 1 6 1 Static Sensitive Devices 6 1 Precautions 6 1 Unpacking 6 1 6 2 Control Panel 6 2 6 3 Chassis Cover...

Страница 7: ...the Configuration Data 7 1 Starting the Setup Utility 7 2 7 1 Main Setup 7 2 7 2 Advanced Setup Configurations 7 4 7 3 Event Logs 7 28 7 4 IPMI 7 30 7 5 Boot 7 32 7 6 Security 7 34 7 7 Save Exit 7 35...

Страница 8: ...8 SuperServer 6027PR HC1 R TR FR Manual Notes...

Страница 9: ...ks with narrow ILM MB SNK P0057PS Four 4 mylar air shrouds MCP 310 21702 Four 4 80x80x38mm cooling fans FAN 0136L4 SATA SAS Backplane Four 4 SAS3 HD expansion cards BPN ADP S3108L H6IRP One 1 SAS Back...

Страница 10: ...iagram Processors Each serverboard supports single or dual Intel Xeon E5 2600 series processors Socket R LGA 2011 Memory Each serverboard has sixteen DIMM slots Up to 1TB DDR3 ECC LRDIMM Up to 512GB D...

Страница 11: ...PHY dedicated to IPMI Infiniband for 6027PR HC1FR only Mellanox ConnectX 3 FDR Infiniband 56Gb s Controller Graphics Matrox G200eW Input Output Ports For each node I O ports include two Ethernet LAN p...

Страница 12: ...and control Front Control Panel The chassis includes four front panels on the handles of the chassis that control each of the systems Each control panel provides system monitoring and control for one...

Страница 13: ...ough IPNM Specification Version 1 5 is supported by the BMC Baseboard Management Controller your system must also have IPNM compatible Manageability Engine ME firmware installed to use this feature Ma...

Страница 14: ...SB LAN I350 2 ports SATA AT25321 LPC CPU FRONT FAN Side CPU REAR I O Side PCI 32 bit USB REAR 0 1 2 H F E Socket 0 Socket 1 1 P0 P0 P1 P1 PE3 PE2 PE1 DMI PE3 PE2 PE1 DMI Gen3 x16 x4 VGA BMC WPCM450 DD...

Страница 15: ...as a stop when a node is fully installed If too much force is used when inserting a node this pin may break off Take care to slowly slide a node in until you hear the click of the locking tab seating...

Страница 16: ...o com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support...

Страница 17: ...Avoid areas where heat electrical noise and electromagnetic fields are generated A nearby grounded power outlet is required The box your chassis was shipped in should include two sets of rail assembli...

Страница 18: ...aneously may cause the rack to become unstable General Server Precautions Review the electrical and general safety precautions that came with the com ponents you are adding to your chassis Determine t...

Страница 19: ...sideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounde...

Страница 20: ...sing Note This rail will fit a rack between 26 5 and 36 4 deep Identifying the Sections of the Rack Rails The chassis package includes two rail assemblies Each assembly consists of three sections An i...

Страница 21: ...k when when the chassis is pulled out for servicing To mount the rail onto the chassis first release the inner rail from the outer rails Releasing Inner Rail from the Outer Rails 1 Pull the inner rail...

Страница 22: ...Place the inner rail firmly against the side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassi...

Страница 23: ...rails to the rack 4 Pull out the rear of the outer rail adjusting the length until it just fits within the posts of the rack 5 Hang the hooks of the rear section of the outer rail onto the square hole...

Страница 24: ...as illustrated above 2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has...

Страница 25: ...view The chassis includes Control panels on the front that include power buttons and status monitoring lights Status lights on externally accessible hard drives Status lights for the power supply Ther...

Страница 26: ...help an operator find this server in a rack of many NIC Indicates network activity when flashing Information LED Alerts operator of several states as noted in the table below Information LED Status De...

Страница 27: ...irm that the chassis covers are installed properly 3 Check the routing of the cables and make sure all fans are present and operat ing normally 4 Verify that the heatsinks are installed properly 3 4 D...

Страница 28: ...power supply is on Solid Amber When illuminated indicates the power supply is plugged in and turned off or the system is off but in an abnormal state Blinking Amber When blinking this system power sup...

Страница 29: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 30: ...ipo considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontr...

Страница 31: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Страница 32: ...chlie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de bra...

Страница 33: ...erstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuito...

Страница 34: ...nd the power cord removed from the power supply module s before accessing the chassis interior to install or remove system components 250V 20A Waarschuwing Dit product is afhankelijk van de kortsluitb...

Страница 35: ...tado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre d branch de toutes les sourc...

Страница 36: ...t Warnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar...

Страница 37: ...eug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m glich Advertencia Esta unidad ha sido dise ada para instalaci n en reas de acceso restringido S lo puede obtenerse acceso a una d...

Страница 38: ...e same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met e...

Страница 39: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 40: ...ustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por com...

Страница 41: ...System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero...

Страница 42: ...g Die Installation der Ger te muss den Sicherheitsstandards entsprechen Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzic...

Страница 43: ...onal laws and regulations Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Attention L quipement doit tre install conform ment aux normes lectriqu...

Страница 44: ...yclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning The fans might still...

Страница 45: ...tfernt Advertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del v...

Страница 46: ...UL CSA Supermicro UL CSA UL CSA Warnung Bei der Installation des Produkts die zur Verf gung gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann z...

Страница 47: ...s dispositivos el ctricos que los productos designados por Supermicro solamente Attention Lors de l installation du produit utilisez les bables de connection fournis ou d sign L utilisation d autres c...

Страница 48: ...n kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL o...

Страница 49: ...nding keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a...

Страница 50: ...that the processors are installed the next step is to connect the cables to the serverboard Connecting Data Cables The cables used to transfer data from the peripheral devices have been carefully rout...

Страница 51: ...only an Intel certified multi directional heatsink Avoid placing direct pressure to the top of the processor package Install the processor into the CPU socket before installing the heatsink Refer to...

Страница 52: ...and edges will fit the socket OPEN1st IMPORTANT Caution You can only install the CPU into the socket in one direction Make sure that the CPU is properly inserted into the socket before closing the loa...

Страница 53: ...and lock the Close 1st lever Push down and lock the lever labeled Open 1st OPEN1st OPEN1st Push down and lock the lever labeled Close 1st 9 Close and lock the Open 1st lever Engage the lip of the load...

Страница 54: ...from the CPU Do not use excessive force 4 Once the heatsink is loosened remove it from the CPU 5 Clean the surface of the CPU and the heatsink to get rid of the old thermal grease Reapply the proper a...

Страница 55: ...32GB 1 35V 1 5V UDIMM 512MB 1GB 2GB 4GB and 8GB LRDIMM 8GB 16GB 32GB and 64GB It is highly recommended that you remove the power cord from the system before installing or changing memory modules Plea...

Страница 56: ...MH1 P2 DIMME2 P2 DIMM F2 P2 DIMMG2 P2 DIMMH2 To Install Insert module vertically and press down until it snaps into place Pay attention to the alignment notch at the bottom To Remove Use your thumbs t...

Страница 57: ...IMMD1 P2 DIMME1 P2 DIMMF1 P2 DIMMG1 P2 DIMMH1 P1 DIMMA2 P1 DIMMB2 P1 DIMMC2 P1 DIMMD2 P2 DIMME2 P2 DIMMF2 P2 DIMMG2 P2 DIMMH2 Installing UDIMM ECC Non ECC Memory Intel E5 2600 V2 Series Processor UDIM...

Страница 58: ...DRx8 2GB 4GB 8GB 1066 1333 1600 1066 1333 1600 1866 1066 1333 1600 1066 1333 1600 1866 1066 1333 1600 1066 1333 1600 1866 SRx4 2GB 4GB 8GB 1066 1333 1600 1066 1333 1600 1866 1066 1333 1600 1066 1333 1...

Страница 59: ...se refer to the SMC Recommended Memory List posted on our website at http www supermicro com support resources mem cfm Other Important Notes and Restrictions For the memory modules to work properly pl...

Страница 60: ...3 FAN4 JSD1 LEB2 LEB1 LEM1 LE3 LE1 J10 JTPM1 JBT1 JIPMB1 IPMI CODE BAR CODE MAC CODE IPMI LAN CPU1 SLOT2 PCI E 3 0 X8 VGA P1 DIMMA1 P1 DIMMA2 P1 DIMMD2 P1 DIMMD1 CPU1 SLOT1 PCI E 3 0 X16 P1 DIMMB2 P1...

Страница 61: ...me is ADMIN and password is ADMIN For BMC best practices please refer to http www supermicro com products nfo files IPMI Best_Practices_BMC_Security pdf X9DRT P PT PIBF Quick Reference Jumper Descript...

Страница 62: ...PIBF JLAN1 10_Gigabit Ethernet LAN Port 1 by the Intel X540 chip for X9DRT PT only JSD1 SATA DOM Device_on_Module Power Connector JTPM1 TPM Trust Platform Module Port 80 Header I SATA0 SATA 0 Connect...

Страница 63: ...LAN controller provides two front accessible USB connections USB 2 3 In addition a Type A USB connection USB 4 located next to the USB 2 3 header also provides front panel USB support on the serverbo...

Страница 64: ...at UIDSW2 on the I O panel and a UID LED indicator is located at UIDLED1 on the serverboard When the user presses the UID switch the UID LED indicator will be turned on Press the UID switch again to...

Страница 65: ...ule Reset 10 3 3V Power Supply Receiver 11 2 wire Serial Interface Clock 12 2 wire Serial Interface Data 13 Ground 14 Receiver Non Inverted Data Output 15 Receiver Inverted Data Output 16 Ground 17 Re...

Страница 66: ...System Management Bus header for the IPMI slot is located at JIPMB1 Connect an appropriate cable here to use the IPMB I2 C connection on your system SMB Header JIPMB1 Pin Definitions Pin Definition 1...

Страница 67: ...is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS 1 First power down th...

Страница 68: ...on Pins 1 2 Enabled Default Pins 2 3 Disabled BMC Enable JPB1 Jumper Settings Jumper Setting Definition Pins 1 2 Enable Default Pins 2 3 Normal GLAN Enable Disable JPL1 enables or disables the LAN Por...

Страница 69: ...for jumper settings Manufacture Mode Select Close Pin 2 and Pin 3 of Jumper JPME2 to bypass SPI flash security and force the system to operate in the Manufacture Mode allowing the user to flash the s...

Страница 70: ...ity Right Active IPMI LAN Activity LED Link LED LAN LEDs The Ethernet LAN port is located on the IO Backplane on the serverboard Each LAN port has two LEDs The Yellow LED indicates activity The Link L...

Страница 71: ...rverboard This LED indicates the status of hard drive activities or SATA activities Also see the layout below for the LED locations Onboard Power LED An Onboard Power LED is located at LE1 on the serv...

Страница 72: ...tary daughter card while SXB2 is used for the proprietary add on card Refer to the layout below for the locations SATA Port A Serial ATA port I SATA0 is located on the serverboard This port provides s...

Страница 73: ...ferred Another option is to go to the Supermicro Website at http www supermicro com products Find the product page for your serverboard here where you may download individual drivers and utilities Aft...

Страница 74: ...system voltages system power consumption fan speed and provides alerts via email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used...

Страница 75: ...5 Interface Display Screen Remote Control Note The SuperDoctor 5 program and User s Manual can be downloaded from the Supermicro web site at http www supermicro com products nfo sms_sd5 cfm For Linux...

Страница 76: ...facturer CR2032 Dispose of used batteries according to the manufacturer s instructions Figure 5 8 Installing the Onboard Battery Please handle used batteries carefully Do not damage the battery in any...

Страница 77: ...very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded me...

Страница 78: ...node are located on the front of the chassis The LEDs inform you of system status See Chapter 3 for details on the LEDs and the control panel buttons SAS or SATA Drives 12 Control Panel Control Panel...

Страница 79: ...onto the chassis as shown above 2 Lift the top cover up and off the chassis 3 Peel off the protective film covering the top cover and the top of the chassis 4 Check that all ventilation openings on th...

Страница 80: ...one in each serverboard drawer p n MCP 310 21702 0B See the illustration below Installing an Air Shroud 1 Confirm that all four fans are in place and are working properly 2 Place the first air shroud...

Страница 81: ...g the chassis internal temperature The SC827HQ system fans are hot swappable There is no need to power down the system when replacing fans and new tools are required for installation Optional Fan Conf...

Страница 82: ...housing up and out of the chassis 4 Push the fan up from the bottom and out of the top of the housing 5 Place the replacement fan into the vacant space in the housing while making sure the arrows on t...

Страница 83: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...

Страница 84: ...cessary to remove the backplane from the chassis Removing the Backplane Removing the Backplane from the Chassis 1 Power down and unplug the system from any power source 2 Remove the chassis cover 3 Di...

Страница 85: ...hassis indicated by the arrows below Figure 6 6 7 Remove the side screw from the side of the chassis Figure 6 7 8 Gently ease the backplane up and out of the chassis Figure 6 8 Figure 6 7 Loosening th...

Страница 86: ...rovided 3 Slide the backplane into the chassis at a slight angle pushing it up against the side of the chassis 4 Ease the backplane forward against the front of the chassis This will aid in the alignm...

Страница 87: ...unded side up Depending upon the configuration of the serverboard being used it is also possible that some of the optional standoffs which are pre installed in the chassis may need to be removed Insta...

Страница 88: ...ccess to the backplane ports 9 Replace the expansion card bracket and secure the bracket with a screw Figure 6 10 Installing the Serverboard in the Node Drawer 6 9 Adapter Card Replacement Each server...

Страница 89: ...screws securing the adapter card to the drawer and set them aside for later use 5 Remove the adapter card from the serverboard drawer Installing the Adapter Card Figure 6 11 1 Place the adapter card i...

Страница 90: ...y PCI slot shield toward the slot clip and remove it from the drawer chassis 5 Insert the expansion card to the riser card expansion slot 6 Insert the riser card into the serverboard expansion slot wh...

Страница 91: ...manuals The SC827HQ chassis contains four individual serverboards in separate node drawers Figure 6 13 Each serverboard node controls a set of three hard drives Note that if a serverboard node drawer...

Страница 92: ...R S MANUAL Removing Hard Drive Trays from the Chassis Figure 6 14 1 Press the release button on the drive tray This extends the drive bay handle 2 Use the handle to pull the drive out of the chassis F...

Страница 93: ...r the drive bays Figure 6 15 Chassis Drive Tray Figure 6 16 Removing Dummy Drive from Tray Drive Tray Dummy Drive 1 1 1 1 Caution Except for short periods of time while swapping hard drives do not ope...

Страница 94: ...rive by tightening all six 6 screws 3 Use the open handle to replace the drive tray into the chassis Make sure the close the drive tray handle Figure 6 17 Installing the Hard Drive Drive Tray SATA Har...

Страница 95: ...s operating Power Supply Replacement If a power supply module must be replaced it can be removed without powering down the system Replacement units can be ordered directly from Supermicro Changing the...

Страница 96: ...6 20 SUPERSERVER 6027PR HC1 R TR FR USER S MANUAL Release Tab Figure 6 18 Changing the Power Supply...

Страница 97: ...d for informational text When an option is selected in the left frame it is highlighted in white Often informational text will accompany it Note The AMI BIOS has default informational messages built i...

Страница 98: ...o not upgrade the BIOS unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall the manufacturer be liable for direct indirect s...

Страница 99: ...key to move between fields The date must be entered in Day MM DD YY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Superm...

Страница 100: ...messages Select Enabled to display the OEM logo instead of the normal POST messages The options are Enabled and Disabled AddOn ROM Display Mode Use this feature to set the display mode for the Option...

Страница 101: ...boot drive The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watch Dog timer will allow the system to automatically reboot when a non recoverable...

Страница 102: ...g Technology Intel VT x Technology Intel SMX Technology L1 Data Cache L1 Code Cache L2 Cache L3 Cache CPU Speed This item displays the speed of the CPU installed in Socket 1 or Socket 2 64 bit This it...

Страница 103: ...overwhelm the processor or damage the system during an attack The default is Enabled Refer to Intel and Microsoft Web sites for more information Intel AES NI Select Enable to use the Intel Advanced En...

Страница 104: ...ory_Number PPIN support which will allow the BIOS setup returns a 64 bit ID number via the PPIN MSR Magnetic Stripe Reader The options are Enabled and Disabled CPU Power Management Configuration This...

Страница 105: ...C State package register The options are C0 C2 C6 and No Limit Energy Performance Bias Use this feature to select an appropriate fan setting to achieve maximum system performance with maximum cooling...

Страница 106: ...e Monitor through the DMAR ACPI Tables This feature offers fully protected I O resource sharing across Intel platforms providing greater reliability security and availability in networking and data sh...

Страница 107: ...ion 2 support for the port specified Select GEN3 to enable PCI Exp Generation 3 support for the port specified The options are GEN1 GEN2 and GEN3 IIO 2 PCIe Port Bifurcation Control This submenu confi...

Страница 108: ...ormation Current Memory Mode This item displays the current memory mode Current Memory Speed This item displays the current memory speed Mirroring This item displays if memory mirroring is supported b...

Страница 109: ...he options are Auto 1 Way 2 Way 3 Way and 4 Way Rank Interleaving This feature allows the user to select a rank memory interleaving method The options are Auto 1 Way 2 Way 4 Way and 8 Way Patrol Scrub...

Страница 110: ...ard memory to enhance memory and system performance The options are Auto Enabled and Disabled South Bridge Configuration This feature allows the user to configure the settings for the Intel PCH chip P...

Страница 111: ...ange will be claimed by the EHCI driver The options are Disabled and Enabled SATA Configuration When this submenu is selected the AMI BIOS automatically detects the presence of the SATA Devices and di...

Страница 112: ...re displayed Serial ATA Port 0 Port 5 This item displays the information detected on the installed SATA drives on the particular SATA port Model number of drive and capacity Software Preserve Support...

Страница 113: ...sing the LSI controller The options are Intel and LSI SATA RAID Option ROM UEFI Driver Available if the item above SATA Mode Select is set to AHCI or RAID Select Enabled to use the SATA RAID Option RO...

Страница 114: ...Generation Select Enabled to allow a PCI device to generate an SERR number for a PCI Bus Signal Error Event The options are Enabled and Disabled Maximum Payload Select Auto to allow the system BIOS t...

Страница 115: ...Onboard LAN2 Option ROM Select Enabled to enable the onboard LAN1 LAN2 Option ROM This is to boot the computer using a network device The default setting for LAN1 Option ROM is Enabled and the defaul...

Страница 116: ...specified The options are Normal and High Speed SOL Serial_Over_LAN Configuration SOL Serial Port Select Enabled to enable a serial port specified by the user The options are Enabled and Disabled Dev...

Страница 117: ...emote computer used by the user Terminal Type This feature allows the user to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII Character set Select VT100...

Страница 118: ...control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data when...

Страница 119: ...ter will exchange data with the client computer which is the remote computer used by the user Out of Band Management Port The feature selects a serial port used by the Microsoft Windows Emergency Mana...

Страница 120: ...caches and stop executing instructions Power to the CPU s and RAM is maintained but RAM is refreshed Select Suspend Disabled to use power reduced mode Power will only be supplied to limited components...

Страница 121: ...his item to schedule an operation for the security device The options are None Enable Take Ownership Disable Take Ownership and TPM Clear Note During restart the computer will reboot in order to execu...

Страница 122: ...endencies This feature displays the features that need to be enabled for the Intel Trusted Execution Technology to work properly in the system VT d Support Intel Virtualization Technology with Direct...

Страница 123: ...he current port The options are AutoNeg 10Mbps Half 10Mbps Full 100Mbps Half and 100Mbps full Wake on LAN Select enabled to wake the system with a magic packet The options are Enabled and Disabled Bli...

Страница 124: ...bling Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Runtime Error Logging Support Sele...

Страница 125: ...e limit when the SMBIOS event log is full Select Do Nothing for the system to do nothing when the SMBIOS event log is full The options are Do Nothing and Erase Immediately SMBIOS Event Log Standard Se...

Страница 126: ...umber and status System Event Log SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Select Yes On next reset to erase...

Страница 127: ...nfiguration This feature allows the BIOS to implement any IP MAC address changes at the next system boot If the option is set to Yes any changes made to the settings below will take effect when the sy...

Страница 128: ...r belongs to The value of each three digit number separated by dots should not exceed 255 Station MAC Address This item displays the Station MAC address for this computer Mac addresses are 6 two digit...

Страница 129: ...BBS Priorities Available when a device is installed in this drive 1st Device 2nd Device USB Hard Disk Drive BBS Priorities Available when a device is installed in this drive 1st Device Network Device...

Страница 130: ...lowing security settings for the system Password Check Use this feature to determine when a password entry is required Select Setup to require the password only when entering setup Select Always to re...

Страница 131: ...to exit the BIOS setup without saving select Yes to quit BIOS without saving the changes or select No to quit the BIOS and save changes Save Changes and Reset When you have completed the system config...

Страница 132: ...u if you want to load optimized defaults select Yes to load the optimized default settings or select No to abandon optimized defaults Save as User Defaults Select this feature and press Enter to save...

Страница 133: ...communicated through a series of audible beeps The numbers on the fatal error list on the following page correspond to the number of beeps for the corresponding error All errors listed with the excep...

Страница 134: ...A 2 SUPERSERVER 6027PR HC1 R TR FR USER S MANUAL Notes...

Страница 135: ...o 1 TB of DDR3 1600 1333 1066 800 MHz registered ECC SDRAM in 1 GB 2 GB 4 GB 8 GB 16 GB or 32 GB size sizes of 1 5V or 1 35V voltages Note Refer to Section 5 6 for details on installation Note Check t...

Страница 136: ...50 to 95 F Non operating Temperature 40 to 70 C 40 to 158 F Operating Relative Humidity 20 to 95 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagn...

Страница 137: ...B 3 Appendix B System Specifications Notes...

Страница 138: ...o perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell suc...

Отзывы: