6-8
S
UPER
S
ERVER 6018R-MT/6018R-MTR User's Manual
6018R-MTR
The SuperServer 6018R-MTR has a 400 watt redundant power supply consisting
of two power modules (PWS-406P-1R). Each power supply module has an auto-
switching capability, which enables it to automatically sense and operate with an
input voltage of 100-240V.
Power Supply Failure
If either of the two power supply modules fail, the other module will take the full
load and allow the system to continue operation without interruption. The Power
LED will illuminate and remain on until the failed unit has been replaced. Replace-
ment units can be ordered directly from Supermicro. The power supply units have
a hot-swap capability, meaning you can replace the failed unit without powering
down the system.
Replacing the Power Supply
1. First unplug the AC power cord from the failed power supply module.
2. To remove the failed power unit, push its release tab to the side to unlock it,
then pull the power supply straight out of the chassis.
3. Replace the failed unit with another unit with another of the same part number
(the exact same power supply).
4. Carefully insert the new unit into position in the chassis and push it in until
fully seated.
5. Reconnect the power cord to the new power supply.
Содержание SUPERSERVER 6018R-MT
Страница 1: ...SUPER SUPERSERVER 6018R MT 6018R MTR Revision 1 0 ...
Страница 5: ...v Preface Notes ...
Страница 16: ...1 6 SUPERSERVER 6018R MT 6018R MTR User s Manual Notes ...
Страница 24: ...2 8 SUPERSERVER 6018R MT 6018R MTR User s Manual Notes ...
Страница 28: ...3 4 SUPERSERVER 6018R MT 6018R MTR User s Manual Notes ...
Страница 48: ...4 20 SUPERSERVER 6018R MT 6018R MTR User s Manual Notes ...
Страница 123: ...Chapter 7 BIOS 7 41 Network Drive BBS Priorities Legacy Boot Order 1 UEFI Application Boot Priorities UEFI Boot Order 1 ...
Страница 126: ...7 44 SUPERSERVER 6018R MT 6018R MTR User s Manual Notes ...
Страница 128: ...A 2 SUPERSERVER 6018R MT 6018R MTR User s Manual Notes ...