7-22
SUPERSERVER 6018R-MT/6018R-MTR User's Manual
•
Software Preserve Support
sSATA Port 0~ Port 3
Select Enabled to enable an sSATA port specified by the user. The options are
Disabled and Enabled.
sSATA Port 0 ~ Port 3 Hot Plug
Select Enabled to enable hot-plugging support for a port specified by the user,
which will allow the user to replace a sSATA disk drive installed on this port
without shutting down the system. The options are
Enabled
and Disabled.
sSATA Port 0 ~ Port 3 Spin Up Device
On an edge detect from 0 to 1, set this item to allow the PCH to start a COMRE-
SET initialization to the device. The options are Enabled and
Disabled
.
Port 0 ~ Port 3 sSATA Device Type
Use this item to specify if the sSATA port specified by the user should be con
-
nected to a Solid State drive or a Hard Disk Drive. The options are Hard Disk
Drive and Solid State Drive.
*If the item above "Configure sSATA as" is set to IDE, the following items will
display:
sSATA Port 0~ Port 3
This item indicates that an sSATA port specified by the user is installed (pres
-
ent) or not.
Port 0 ~ Port 3 sSATA Device Type (Available when a SATA port is
detected)
Use this item to specify if the sSATA port specified by the user should be con
-
nected to a Solid State drive or a Hard Disk Drive. The options are Hard Disk
Drive and Solid State Drive.
*If the item above "Configure sSATA as" is set to RAID, the following items will
display:
Support Aggressive Link Power Management
When this item is set to Enabled, the SATA AHCI controller manages the power
usage of the SATA link. The controller will put the link to a low power state when
the I/O is inactive for an extended period of time, and the power state will return
to normal when the I/O becomes active. The options are
Enabled
and Disabled.
Содержание SUPERSERVER 6018R-MT
Страница 1: ...SUPER SUPERSERVER 6018R MT 6018R MTR Revision 1 0 ...
Страница 5: ...v Preface Notes ...
Страница 16: ...1 6 SUPERSERVER 6018R MT 6018R MTR User s Manual Notes ...
Страница 24: ...2 8 SUPERSERVER 6018R MT 6018R MTR User s Manual Notes ...
Страница 28: ...3 4 SUPERSERVER 6018R MT 6018R MTR User s Manual Notes ...
Страница 48: ...4 20 SUPERSERVER 6018R MT 6018R MTR User s Manual Notes ...
Страница 123: ...Chapter 7 BIOS 7 41 Network Drive BBS Priorities Legacy Boot Order 1 UEFI Application Boot Priorities UEFI Boot Order 1 ...
Страница 126: ...7 44 SUPERSERVER 6018R MT 6018R MTR User s Manual Notes ...
Страница 128: ...A 2 SUPERSERVER 6018R MT 6018R MTR User s Manual Notes ...