Chapter 7: BIOS
7-19
it easier for the user to understand the CPU’s temperature status, rather than
by just simply seeing a temperature reading (i.e., 25
o
C).
The information provided above is for your reference only. For more information
on thermal management, please refer to Intel’s Web site at www.Intel.com.
2. To avoid possible system overheating, please provide adequate airfl ow to
the system.
IOH Temperature/System Temperature
The IOH Temperature and the system temperature will be displayed (in degrees in
Celsius and Fahrenheit) as detected by the BIOS.
Fan Speed Readings
This feature displays the fan speed readings from Fan 1 through Fan 6.
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlated. When the
CPU on-die temperature increases, the fan speed will also increase for effective
system cooling. Select "Full Speed/FS" to allow the onboard fans to run at full
speed for maximum cooling. The FS setting is recommended for special system
confi guration or debugging. Select "Performance/PF" for better system cooling. The
PF setting is recommended for high-power-consuming and high-density systems.
Select "Balanced/BL" for the onboard fans to run at a speed that will balance the
needs between system cooling and power saving. The BL setting is recommended
for regular systems with normal hardware confi gurations. Select "Energy Saving/ES"
for best power effi ciency and maximum quietness. The Options are: Full Speed/FS,
Performance/PF,
Balanced/BL
, and Energy Saving/ES.
Voltage Readings
The following voltage readings will be displayed.
CPU1 Vcore, CPU2 Vcore, CUP1 DIMM, CPU DIMM, 5V, 5VSB, 12V, -12V, 3.3Vcc,
3.3VSB, VBAT and Vtt
X
ACPI Confi guration
Use this feature to confi gure Advanced Confi guration and Power Interface (ACPI)
power management settings for your system.
High Precision Event Timer
Select Enabled to activate the High Precision Event Timer (HPET) that produces
periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does
in synchronizing multimedia streams, providing smooth playback and reducing
Содержание SUPERSERVER 6016T-MR
Страница 1: ...SUPER SUPERSERVER 6016T MR USER S MANUAL Revision 1 0a...
Страница 5: ...v Preface Notes...
Страница 10: ...Notes x SUPERSERVER 6016T MR User s Manual...
Страница 16: ...1 6 SUPERSERVER 6016T MR User s Manual Notes...
Страница 24: ...2 8 SUPERSERVER 6016T MR User s Manual Figure 2 4 Installing the Server into a Telco Rack...
Страница 28: ...2 12 SUPERSERVER 6016T MR User s Manual Notes...
Страница 32: ...3 4 SUPERSERVER 6016T MR User s Manual Notes...
Страница 68: ...6 6 SUPERSERVER 6016T MR User s Manual Figure 6 3 Removing the DVD ROM Drive...
Страница 98: ...7 28 SUPERSERVER 6016T MR User s Manual Notes...
Страница 100: ...A 2 SUPERSERVER 6016T MR User s Manual Notes...