7-10
SUPERSERVER 6016T-MR User's Manual
Demand Scrubbing
It is a memory error-correction scheme where the processor writes corrected
data back into the memory block from where it was read by the processor. The
options are Enabled and
Disabled
.
Patrol Scrubbing
It is a memory error-correction scheme that works in the background looking for
and correcting resident errors. The options are
Enabled
and Disabled.
Throttling - Closed Loop
Throttling improves reliability and reduces CPU power by automatic voltage
control during CPU idle states. The options are
Enabled
and Disabled.
X
NorthBridge Chipset Confi guration
This feature allows the user to confi gure North Bridge settings. The items included
in the submenu are listed below.
NB Revision
•
: This item displays North Bridge revision number.
Intel I/OAT
The Intel I/OAT (I/O Acceleration Technology) signifi cantly reduces CPU overhead
by leveraging CPU architectural improvements, freeing resources for more other
tasks. The options are Disabled and
Enabled
.
DCA Technology (Available when Intel I/OAT is enabled)
Select Enabled to use Intel's DCA (Direct Cache Access) Technology to enhance
data transfer effi ciency. The options are
Enabled
and Disabled.
DCA Prefetch Delay
A DCA Prefetch is used with TOE components to prefetch data in order to shorten
execution cycles and maximize data processing effi ciency. Prefetching too frequently
can saturate the cache directory and delay necessary cache accesses. This feature
reduces or increases the frequency the system prefetches data. The options are [8],
[16], [24],
[32]
, [40], [48], [56], [64], [72], [80], [88], [96], [104], [112], [120].
Intel VT-d
Select Enabled to enable Intel's Virtualization Technology support for Direct I/O VT-d
by reporting the I/O device assignments to VMM through the DMAR ACPI Tables.
This feature offers fully-protected I/O resource-sharing across the Intel platforms,
providing the user with greater reliability, security and availability in networking and
data-sharing. The options are Enabled and
Disabled
.
Содержание SUPERSERVER 6016T-MR
Страница 1: ...SUPER SUPERSERVER 6016T MR USER S MANUAL Revision 1 0a...
Страница 5: ...v Preface Notes...
Страница 10: ...Notes x SUPERSERVER 6016T MR User s Manual...
Страница 16: ...1 6 SUPERSERVER 6016T MR User s Manual Notes...
Страница 24: ...2 8 SUPERSERVER 6016T MR User s Manual Figure 2 4 Installing the Server into a Telco Rack...
Страница 28: ...2 12 SUPERSERVER 6016T MR User s Manual Notes...
Страница 32: ...3 4 SUPERSERVER 6016T MR User s Manual Notes...
Страница 68: ...6 6 SUPERSERVER 6016T MR User s Manual Figure 6 3 Removing the DVD ROM Drive...
Страница 98: ...7 28 SUPERSERVER 6016T MR User s Manual Notes...
Страница 100: ...A 2 SUPERSERVER 6016T MR User s Manual Notes...
Страница 105: ...C 3 Appendix C System Specifications Notes...