Chapter 5: Advanced Serverboard Setup
5-5
Gently push
down to pop
the load plate
open.
3. With the lever labeled 'Close 1st'
fully retracted, gently push down
on the 'Open 1st' lever to open the
load plate. Lift the load plate to
open it completely.
4. Using your thumb and the index
finger, remove the 'WARNING'
plastic cap from the socket.
5.
Use your thumb and index finger
to hold the CPU by its edges. Align
the CPU keys, which are semi-
circle cutouts, against the socket
keys.
6. Once they are aligned, carefully
lower the CPU straight down into
the socket. (Do not drop the CPU
on the socket. Do not move the
CPU horizontally or vertically and
do not rub the CPU against any
pins of the socket, which may
damage the CPU or the socket.)
WARNING
!
OPEN 1st
WARNING
!
Socket Keys
CPU Keys
Caution:
You can only install the CPU to the socket in one direction. Make sure
that the CPU is properly inserted into the socket before closing the load plate. If it
doesn't close properly, do not force it as it may damage your CPU. Instead, open
the load plate again and double-check that the CPU is aligned properly.
Содержание SuperServer 5028R-WR
Страница 1: ...SUPERSERVER 5028R WR SUPER USER S MANUAL 1 0...
Страница 5: ...Notes Preface v...
Страница 14: ...1 6 SUPERSERVER 5028R WR User s Manual Notes...
Страница 22: ...2 8 SUPERSERVER 5028R WR User s Manual Notes...
Страница 26: ...SUPERSERVER 5028R WR User s Manual 3 4 Notes...
Страница 46: ...4 20 SUPERSERVER 5028R WR User s Manual Notes...
Страница 74: ...5 28 SUPERSERVER 5028R WR User s Manual Notes...
Страница 81: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 6 Removing System Cooling Fans...
Страница 126: ...A 2 SUPERSERVER 5028R WR User s Manual Notes...
Страница 129: ...B 3 Appendix B System Specifications Notes...