5-6
S
UPER
S
ERVER 5015B-T User's Manual
Warning!
Make sure you lift the lever completely when installing the CPU;
otherwise, damage to the socket or CPU may occur.
!
Socket key
CPU installed in socket
PnP cap released
from load plate
CPU key
CPU pin 1
Notched corner
Gold dot
Load lever
Once aligned, carefully lower
the CPU straight down into the
socket. Do not drop the CPU on
the socket, do not move the CPU
horizontally or vertically and do not
rub the CPU against any surface
or any of the contacts, which may
damage the CPU and/or contacts.
With the CPU in the socket, in-
spect the four corners of the CPU
to make sure that it is properly
installed.
Use your thumb to gently push the
load lever down until it snaps into
the retention clasp.
If the CPU is properly installed
into the socket, the PnP cap will
be automatically released from the
load plate when the lever locks.
Remove the cap. Repeat steps to
install a second CPU if desired.
Warning!
Keep the plastic PnP cap.
The serverboard must be shipped with
the PnP cap properly installed to protect
the CPU socket. Shipment without the
6.
7.
8.
9.
Содержание SUPERSERVER 5015B-T
Страница 1: ...SUPER USER S MANUAL Revision 1 0 SUPERSERVER 5015B T...
Страница 5: ...v Preface Notes...
Страница 14: ...1 6 SUPERSERVER 5015B T User s Manual Notes...
Страница 21: ...Chapter 2 Server Installation 2 7 Figure 2 4 Installing the Server into a Telco Rack...
Страница 28: ...3 4 SUPERSERVER 5014C T User s Manual Notes...
Страница 94: ...A 6 SUPERSERVER 5015B T User s Manual Notes...
Страница 100: ...B 6 SUPERSERVER 5015B T User s Manual Notes...