Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 5015B-T up
and running. Following the steps in the order given should enable you to have the
system operational within a minimal amount of time. This quick setup assumes that
your 5015B-T system has come to you with the processor and memory preinstalled.
If your system is not already fully integrated with a motherboard, processor, system
memory etc., please turn to the chapter or section noted in each step for details on
installing specifi c components.
2-2 Unpacking
the
System
You should inspect the box the SuperServer 5015B-T was shipped in and note if
it was damaged in any way. If the server itself shows damage, you should fi le a
damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 5015B-T.
It should be situated in a clean, dust-free area that is well ventilated. Avoid areas
where heat, electrical noise and electromagnetic fi elds are generated. You will also
need it placed near a grounded power outlet. Read the Rack and Server Precau-
tions in the next section.
2-3 Preparing for Setup
The box the SuperServer 5015B-T was shipped in should include two sets of rail
assemblies, two rail mounting brackets and the mounting screws you will need to
install the system into the rack. Follow the steps in the order given to complete
the installation process in a minimal amount of time. Please read this section in
its entirety before you begin the installation procedure outlined in the sections that
follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for suffi cient airfl ow and ease in servicing.
•
Содержание SUPERSERVER 5015B-T
Страница 1: ...SUPER USER S MANUAL Revision 1 0 SUPERSERVER 5015B T...
Страница 5: ...v Preface Notes...
Страница 14: ...1 6 SUPERSERVER 5015B T User s Manual Notes...
Страница 21: ...Chapter 2 Server Installation 2 7 Figure 2 4 Installing the Server into a Telco Rack...
Страница 28: ...3 4 SUPERSERVER 5014C T User s Manual Notes...
Страница 94: ...A 6 SUPERSERVER 5015B T User s Manual Notes...
Страница 100: ...B 6 SUPERSERVER 5015B T User s Manual Notes...