Chapter 6: Advanced Chassis Setup
6-5
2. Align the drive in the carrier so that the screw holes of both line up. Note that
there are holes in the carrier marked “SATA” to aid in correct installation.
3. Secure the drive to the carrier with four screws as illustrated below.
4. Insert the drive carrier into its bay, keeping the carrier oriented so that the
hard drive is on the top of the carrier and the release button is on the right
side. When the carrier reaches the rear of the bay, the release handle will
retract.
5. Push the handle in until it clicks into its locked position
Warning!
Except for short periods of time (such as for swapping hard drives), do not
operate the server with the hard drive carriers empty.
Figure 6-3: Installing a Hard Drive into a Carrier
Removing a Hard Drive (Figure 6-4)
1. To remove a carrier, push the release button located beside the drive LEDs.
2. Swing the handle fully out and use it to pull the unit straight out (see Figure
6-4).
Note:
Your operating system must have RAID support to enable the hot-plug ca-
pability of the hard drives.
Содержание SUPERSERVER 1026T-UF
Страница 1: ...SUPERSERVER 1026T URF SUPERSERVER 1026T UF SUPER USER S MANUAL 1 0b...
Страница 5: ...v Preface Notes...
Страница 21: ...Chapter 2 Server Installation 2 7 SCALE 0 380 Figure 2 4 Installing the Outer Rails to the Rack 2 3 3...
Страница 24: ...2 10 SUPERSERVER 1026T URF 1026T UF User s Manual Figure 2 6 Installing the Server into a Telco Rack...
Страница 50: ...4 20 SUPERSERVER 1026T URF 1026T UF User s Manual Notes...
Страница 86: ...6 10 SUPERSERVER 1026T URF 1026T UF Manual Notes...
Страница 112: ...A 2 SUPERSERVER 1026T URF 1026T UF User s Manual Notes...