Chapter 6: Advanced Chassis Setup
6-3
Adding a System Fan
1. Turn off the power to the system and unplug the power cord.
2. Remove the chassis cover then remove the dummy fan from the fan tray.
3. Place the new fan into the vacant space in the housing while making sure the
arrows on the top of the fan (indicating air direction) point in the same direc-
tion as the arrows on the other fans.
4. Connect the fan wires to the fan header on the serverboard.
5. Power up the system and check that the fan is working properly before re-
placing the chassis cover.
System Fan Failure
Fan speed is controlled by system temperature via a BIOS setting. If a fan fails,
the remaining fans will ramp up to full speed. Replace any failed fan at your earli-
est convenience with the same type and model (the system can continue to run
with a failed fan).
The SC113 chassis includes four pre-installed fans. Two additional open slots are
available so that up to two more fans may be added.
Replacing a System Fan (Figure 6-2)
1. Open the chassis while the system is running to determine which fan has
failed. Never run the server for an extended period of time with the chassis
open.
2. Turn off the power to the system and unplug the power cord.
3. Remove the failed fan's wiring from the fan header on the serverboard.
4. Lift the failed fan from the chassis and pull it completely out.
5. Place the new fan into the vacant space in the housing while making sure the
arrows on the top of the fan (indicating air direction) point in the same direc-
tion as the arrows on the other fans.
6. Reconnect the fan wires to the same chassis fan header as the previous fan.
7. Power up the system and check that the fan is working properly before re-
placing the chassis cover.
Содержание SUPERSERVER 1026T-UF
Страница 1: ...SUPERSERVER 1026T URF SUPERSERVER 1026T UF SUPER USER S MANUAL 1 0b...
Страница 5: ...v Preface Notes...
Страница 21: ...Chapter 2 Server Installation 2 7 SCALE 0 380 Figure 2 4 Installing the Outer Rails to the Rack 2 3 3...
Страница 24: ...2 10 SUPERSERVER 1026T URF 1026T UF User s Manual Figure 2 6 Installing the Server into a Telco Rack...
Страница 50: ...4 20 SUPERSERVER 1026T URF 1026T UF User s Manual Notes...
Страница 86: ...6 10 SUPERSERVER 1026T URF 1026T UF Manual Notes...
Страница 112: ...A 2 SUPERSERVER 1026T URF 1026T UF User s Manual Notes...