3-2
4042G-6RF/TRF User's Manual
3-3 Control Panel LEDs
The control panel located on the front of the SC748TS-R1400BP chassis has five
LEDs. These LEDs provide you with critical information related to different parts of
the system. This section explains what each LED indicates when illuminated and
any corrective action you may need to take.
Power Fail
Indicates a power supply module has failed. The second power supply module will
take the load and keep the system running but the failed module will need to be
replaced. Refer to Chapter 6 for details on replacing the power supply. This LED
should be off when the system is operating normally
Information LED
Alerts operator of several states, as noted in the table below.
Informational LED
Status
Description
Continuously on and red
An overheat condition has occured.
(This may be caused by cable congestion.)
Blinking red (1Hz)
Fan failure, check for an inoperative fan.
Blinking red (0.25Hz)
Power failure, check for a non-operational power supply.
Solid blue
Local UID has been activated. Use this function to locate
the server in a rack mount environment.
Blinking blue
Remote UID is on. Use this function to identify the
server from a remote location.
Содержание A+ SERVER 4042G-6RF
Страница 1: ... SUPER A SERVER 4042G 6RF TRF USER S MANUAL Revision 1 0d ...
Страница 5: ...v Preface Notes ...
Страница 10: ...Notes x A SERVER 4042G 6RF TRF User s Manual ...
Страница 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System ...
Страница 30: ...3 4 4042G 6RF TRF User s Manual Notes ...
Страница 50: ...4 20 A SERVER 8027R TRF 7RFT User s Manual Notes ...
Страница 92: ...6 10 A SERVER 4042G 6RF TRF User s Manual Figure 6 7 Removing a Power Supply Module ...
Страница 110: ...A 2 A SERVER 4042G 6RF TRF User s Manual Notes ...