33
SuperStorage SSG-136R-NR32JBF User's Manual
3.
Before removing or ejecting any SSD, confirm its location information by right clicking its
icon and opening the Hardware tab from the Properties selection:
Figure 3-6. Hardware Tab
If all the NVMe SSDs installed are from a single JBOF and the host detected all 32 NVMe
SSDs installed in the JBOD, the Location # of a SSD would be its slot number in the JBOF,
which is also its Disk # presented in Disk Management, except for the SSD with Location #
as 1. If installed NVMe SSDs are mixed from different enclosures including both server and
JBOF(s), more information is needed to correctly prepare the target SSD for the disk number.
4.
Remove/eject a target NVMe SSD (Simple Case).
If all NVMe SSDs installed on the host are from the same JBOF and the Location # of the
target SSD is not 1, confirm that the SSD icon’s Location number under Devices and Printer
Management matches with the Disk number of the target SSD. If they do, the target SSD
may be removed/ejected by right clicking its icon (under Devices and Printers Management),
then click Remove device, then confirm the action by clicking on the Yes button in the pop-
up window.