![Supermicro SuperStorage SSG-136R-NR32JBF Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/supermicro/superstorage-ssg-136r-nr32jbf/superstorage-ssg-136r-nr32jbf_user-manual_1404831024.webp)
24
SuperStorage SSG-136R-NR32JBF User's Manual
2.4 Powering On the System
Any time you power on the SSG-136R-NR32JBF system, first perform the following
precautions:
1.
Verify that all hosts that will use the SSG-136R-NR32JBF are powered off.
2. Connect PCI-E cabling from the hosts to the SSG-136R-NR32JBF.
3. Connect a power cord from a grounded AC outlet to the SSG-136R-NR32JBF. Do
not
power on the system.
4. Wait two minutes for the BMC service to power on.
5. Press the power button on the SSG-136R-NR32JBF, or power on the system using the
IPMI command interface.
6. Wait three minutes, then power on the hosts that are connected to the system.
2.5 Assigning Drives to Host Servers
When you boot up the system for the first time, you must assign the NVMe drives to attached
hosts. You can view and modify drive assignment using the Web GUI or the command line.
Refer to your preferred procedure in Appendix C.