background image

SUPERSERVER

®

8048B-TR3F

8048B-C0R3FT

USER’S MANUAL

Revision 1.0

Содержание SUPERSERVER 8048B-C0R3FT

Страница 1: ...SUPERSERVER 8048B TR3F 8048B C0R3FT USER S MANUAL Revision 1 0...

Страница 2: ...f any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limit...

Страница 3: ...assis Chapter 2 Server Installation This chapter describes the steps necessary to install the SuperServer 8048B TR3F C0R3FT into a rack and check out the server configuration prior to powering up the...

Страница 4: ...ven in this chapter when installing removing or reconfiguring SAS SATA or peripheral drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes an in...

Страница 5: ...Notes Preface v...

Страница 6: ...ont Control Panel 1 5 I O 1 5 Mounting Rails Optional 1 5 Cooling System 1 5 1 4 Advanced Power Management 1 6 Intel Intelligent Power Node Manager NM 1 6 Manageability Engine ME 1 6 1 5 Contacting Su...

Страница 7: ...4 1 About Standardized Warning Statements 4 1 Warning Definition 4 1 Installation Instructions 4 4 Circuit Breaker 4 5 Power Disconnection Warning 4 6 Equipment Installation 4 8 Restricted Area 4 9 B...

Страница 8: ...Explanation of Jumpers 5 26 5 10 Onboard Indicators 5 29 5 11 SAS SATA Ports 5 31 5 12 Installing Software 5 32 SuperDoctor 5 5 33 5 13 Serverboard Battery 5 35 Chapter 6 Advanced Chassis Setup 6 1 St...

Страница 9: ...7 1 7 2 Main Setup 7 2 7 3 Advanced Setup Configurations 7 3 7 4 Event Logs 7 30 7 5 IPMI 7 32 7 6 Security 7 35 7 7 Boot 7 36 7 8 Save Exit 7 38 Appendix A BIOS Error Beep Codes A 1 BIOS Error Beep C...

Страница 10: ...Notes x SUPERSERVER 8048B TR3F C0R3FT User s Manual...

Страница 11: ...748 MCP 310 74806 0B Chassis Fans Three 3 92x92x38 mm 9 7K RPM PWM fans for SC748 FAN 0146L4 Three 3 80x80x38 mm 11K RPM PWM fans for SC748 FAN 0148L4 One 1 77 cm USB 2 0 10p to 10p cable CBL 0263L On...

Страница 12: ...sockets Each processor supports three full width Intel QuickPath Interconnect QPI links Data Transfer Rate of up to 9 6 GT s per direction Please refer to our web site for a complete listing of suppo...

Страница 13: ...refer to the IPMI User s Guide posted on our website at http www supermicro com support manuals Graphics Controller The X10QBL CT features an integrated ASpeed AST2400 BMC Baseboard Controller for a g...

Страница 14: ...TA or SAS hard drives in a M35 mobile rack with an additional five 3 5 hard drives available with a second optional M35 mobile rack installed Mobile Rack The SC748 tower 4U rackmount chassis includes...

Страница 15: ...rt USB 2 0 ports three rear plus two via headers and one Type A a dedicated IPMI LAN port two gigabit Ethernet ports and a UID switch Mounting Rails Optional The SC748 can be placed in a rack for secu...

Страница 16: ...er CTRL Memory Buffer CTRL X10QBL CT only X10QBL CT X10QBL i350 Memory Buffer CTRL PCIE PHY PHY PCIE X8 1 4 Advanced Power Management Intel Intelligent Power Node Manager NM The Intel Intelligent Powe...

Страница 17: ...e Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro...

Страница 18: ...1 8 SUPERSERVER 8048B TR3F C0R3FT User s Manual Notes...

Страница 19: ...a suitable location for the rack unit that will hold the SuperServer 8048B TR3F C0R3FT It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise a...

Страница 20: ...gether Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more simultaneously may cause the rack to become u...

Страница 21: ...i unit rack assembly the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipme...

Страница 22: ...tability Hazard The rack stabilizing mechanism must be in place or the rack must be bolted to the floor before you slide the unit out for servicing Failure to stabilize the rack can cause the rack to...

Страница 23: ...sis on its side with the chassis side cover facing upward 2 Remove the screw holding the chassis foot in place 3 The foot lock is a tab located in the center of the foot that prevents the foot from sl...

Страница 24: ...he rack itself see Figure 2 2 for details Installing the Chassis Handles and Inner Rails 1 Locate the chassis handles 2 and handle screws 6 Figure 2 3 Figure 2 2 Identifying the Inner Rails Chassis Ha...

Страница 25: ...lling the Inner Rack Rails 5 Align the inner rails against the chassis as shown in Figure 2 4 Confirm that the rails are flushed against the edge of the chassis 6 Tighten the screws Do not over tighte...

Страница 26: ...oth the brackets to the proper distance so that the rail fits snugly into the rack 3 Secure the front side of the outer rail with two M5 screws and the rear side of the outer rail with three M5 screws...

Страница 27: ...stallation 2 9 Installing the Chassis into a Rack 1 Confirm that chassis includes the inner rails and the outer rails 2 Line chassis rails with the front of the rack rails Figure 2 6 Figure 2 6 Instal...

Страница 28: ...he rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting When the server has been pushed completely into the rack you should hear the locking tabs...

Страница 29: ...structions in this section if you have converted the chassis for rack use and need to return the chassis to tower mounting Installing the Chassis Cover 1 Remove the rack mount ears Figure 2 8 Adding t...

Страница 30: ...assis 3 Press the release tabs simultaneously 4 Slide the cover forward Figure 2 9 Placing Chassis Feet Chassis Foot Receptacle Chassis Foot Chassis Screw approximately one half inch over the front of...

Страница 31: ...n 2 Your 8048B TR3F C0R3FT server system may have come with system memory already installed Make sure all DIMMs are fully seated in their slots For details on adding system memory refer to Chapter 5 3...

Страница 32: ...r system may have one or more drives already installed If you need to install hard drives please refer to Chapter 6 Checking the Airflow 1 Make sure there are no objects obstructing the airflow in and...

Страница 33: ...e 3 1 Chapter 3 System Interface 3 1 Overview Most SC748 tower 4U rackmount chassis models have two buttons on the chassis a control panel a reset button and an on off switch Figure 4 1 Front Control...

Страница 34: ...r supplied to the system Therefore you must unplug system before servicing Reset Use the reset button to reboot the system 3 3 Control Panel LEDs The control panel located on the front of the chassis...

Страница 35: ...units Universal Information LED See the following table for the status shown by this LED Universal Information LED Status Description Continously on and red An overheat ocondition has occured This ma...

Страница 36: ...atus Activity LED Green Solid On SAS drive installed Green Blinking I O activity Status LED Red Solid On Failed drive for SAS SATA with RSTe support Red Blinking at 1 Hz Rebuild drive for SAS SATA wit...

Страница 37: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 38: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 39: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Страница 40: ...chlie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de bra...

Страница 41: ...erstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuito...

Страница 42: ...d the power cord removed from the power supply module s before accessing the chassis interior to install or remove system components 250V 20A Waarschuwing Dit product is afhankelijk van de kortsluitbe...

Страница 43: ...tado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre d branch de toutes les sourc...

Страница 44: ...Warnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar...

Страница 45: ...eug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m glich Advertencia Esta unidad ha sido dise ada para instalaci n en reas de acceso restringido S lo puede obtenerse acceso a una d...

Страница 46: ...e same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met e...

Страница 47: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 48: ...ustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por com...

Страница 49: ...System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero...

Страница 50: ...Die Installation der Ger te muss den Sicherheitsstandards entsprechen Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzich...

Страница 51: ...onal laws and regulations Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Attention L quipement doit tre install conform ment aux normes lectriqu...

Страница 52: ...yclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning The fans might still...

Страница 53: ...tfernt Advertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del v...

Страница 54: ...UL CSA Supermicro UL CSA UL CSA Warnung Bei der Installation des Produkts die zur Verf gung gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann z...

Страница 55: ...s dispositivos el ctricos que los productos designados por Supermicro solamente Attention Lors de l installation du produit utilisez les bables de connection fournis ou d sign L utilisation d autres c...

Страница 56: ...kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of...

Страница 57: ...ng keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a gr...

Страница 58: ...e layout on page 5 9 for connector locations Important Make sure the the cables do not come into contact with the fans Connecting Power Cables The X10QBL CT serverboard has a 24 pin primary power supp...

Страница 59: ...Control Panel Header Pins Power Button OH Fan Fail PWR Fail LED 1 NIC1 Link LED Reset Button 2 Power Fail LED HDD LED FP PWRLED Reset PWR 3 3 V UID Switch UID LED Ground Ground 19 20 3 3V X Ground NMI...

Страница 60: ...ts I O Ports 1 COM Port 2 Back Panel Vertical USB 2 0 Port 2 3 VGA Blue 4 Back Panel USB 2 0 Port 1 5 Back Panel USB 2 0 Port 0 6 IPMI_LAN 7 Gigabit_LAN 1 see note below 8 Gigabit_LAN 2 see note below...

Страница 61: ...3 Make sure to install the motherboard into the chassis before you install the CPU heatsink 4 When receiving a motherboard without a processor pre installed make sure that the plastic CPU socket cap...

Страница 62: ...cking position 1 OPEN1st OPEN1st Press down on the Load Lever labeled Close 1st 2 Pull the lever away from the socket OPEN1st OPEN1st 2 Gently push down to pop the load plate open OPEN1st OPEN1st 1 3...

Страница 63: ...cket Do not drop the CPU on the socket Do not move the CPU horizontally or vertically Do not rub the CPU against the surface or against any pins of the socket to avoid damaging the CPU or the socket W...

Страница 64: ...r Lock Lever Lock Push down and lock the lever labeled Open 1st Push down and lock the lever labeled Close 1st Gently close the load plate 1 2 3 4 OPEN1st OPEN1st OPEN1st OPEN1st 8 Close the load plat...

Страница 65: ...tsink on top of the CPU so that the four mounting holes are aligned with those on the Motherboard s and the Heatsink Bracket underneath 3 Screw in two diagonal screws i e the 1 and the 2 screws until...

Страница 66: ...tsink to loosen it from the CPU Do not use excessive force when wriggling the heatsink 3 Once the CPU is loosened remove the CPU from the CPU socket 4 Remove the used thermal grease and clean the surf...

Страница 67: ...CPU1 CPU2 CPU3 CPU4 be installed Using three CPUs is not recommended Please install your DIMM modules according to the number of CPUs used in the system 2 To optimize memory performance please install...

Страница 68: ...IMM A2 B2 P1M1 DIMM C2 D2 CPU2 P2M1 P2M1 DIMM A1 B1 P2M1 DIMM C1 D1 P2M1 DIMM A2 B2 P2M1 DIMM C2 D2 CPU3 P3M1 P3M1 DIMM A1 B1 P3M1 DIMM C1 D1 P3M1 DIMM A2 B2 P3M1 DIMM C2 D2 CPU4 P4M1 P4M1 DIMM A1 B1...

Страница 69: ...o the SMC Recommended Memory List posted on our website at http www supermicro com support resources mem cfm Performance Mode 2 1 DDR3 RDIMM LRDIMM Configuration 3SPC Type Ranks Per DIMM Data Width Me...

Страница 70: ...cfm RDIMM LRDIMM DDR3 ECC in Lockstep Mode 1 1 3SPC Type Ranks Per DIMM Data Width Memory DIMM Capacity GB See the Note Below Max Speed Ghz Voltage V Slots per Channel SPC and DIMM per Channel DPC 3 S...

Страница 71: ...3B tower 4U rackmount chassis can accommodate four PCI low profile expansion card slots that are available in the rear of the chassis for two 2 PCI E 3 0 x16 slots CPU1 Slot1 CPU2 Slot3 and two 2 PCI...

Страница 72: ...JPWR3 JPWR5 JPWR4 JPWR1 JL1 JPSAS1 JI2C2 J17 LED1 P3M1 DIMMA2 P2M1 DIMMD2 P2M1 DIMMC2 P1M1 DIMMA1 P1M1 DIMMB1 P1M1 DIMMC1 P1M1 DIMMD1 P2M1 DIMMA1 P2M1 DIMMC1 P2M1 DIMMD1 P3M1 DIMMB1 P3M1 DIMMC1 P3M1...

Страница 73: ...1 10G LAN1 10G LAN2 Enable X10QBL CT Pins 1 2 Enabled JPT1 Trusted Platform Module TPM Enable Pins 1 2 Enabled JPME2 Manufacture Mode ME Select Pins 1 2 Normal JPS1 SAS Enable For X10QBL CT Pins 1 2 E...

Страница 74: ...2 for X10QBL CT 10G LAN TLAN ports 1 2 supported by Intel X540 LAN controller IPMI_LAN Gigabit IPMI dedicated LAN on the I O back panel supported by the BMC for IPMI use L SAS0 3 L SAS4 7 for X10QBL C...

Страница 75: ...5V 9 5VSB 22 5V 10 12V 23 5V 11 12V 24 COM 12 3 3V Power Button Pin Definitions JF1 Pin Definition 1 PW_ON 2 Ground Processor Power Connector The Reset Button connection is located on pins 3 and 4 of...

Страница 76: ...tions OH Fan Fail PWR Fail Blue_ UID LED Pin Definitions JF1 Pin Definition 7 Blue_UID LED 8 OH Fan Fail Power Fail OH Fan Fail PWR Fail LED Status Red LED State Definition Off Normal On Overheat Flas...

Страница 77: ...ton Pin Definitions JF1 Pin Definition 19 Control 20 Ground Fan Header Pin Definitions Pin Definition 1 Ground 2 12V 3 Tachometer 4 PWM Modulation HDD UID LED The HDD LED connection is located on pins...

Страница 78: ...e I O back panel Two internal USB headers located next to the I SATA ports 4 5 provide four USB 2 0 connections USB 4 5 6 7 for front access In addition a Type A USB header located close to the 24 pin...

Страница 79: ...to turn off the LED indicator The UID Indicators provide easy identification of a system unit that may be in need of service Note UID can also be triggered via IPMI on the motherboard For more informa...

Страница 80: ...e tables on the right for pin definitions PWR LED Connector Pin Definitions Pin Setting Definition Pin 1 JD1_PIN1 Pin2 FP_PWR_LED Pin3 FP_PWR_LED Speaker Connector Pin Settings Pin Setting Definition...

Страница 81: ...round 4 Data 5 Load 6 Ground 7 Clock 8 NC NC No Connection Power SMB Pin Definitions Pin Definition 1 Clock 2 Data 3 PWR Fail 4 Ground 5 3 3V Power SMB I2 C Connector Power System Management Bus I2 C...

Страница 82: ...wn the system remove the AC power cord and then short JBT1 to clear CMOS Note 2 Be sure to remove the onboard CMOS Battery before you short JBT1 to clear CMOS Note 3 Clearing CMOS will also clear all...

Страница 83: ...the table on the right for jumper settings LAN Enable Disable JPL1 enables or disables Gigabit_LAN ports on the X10QBL CT while JPTG1 enables or disables 10G LAN ports on the X10QBL T See the table o...

Страница 84: ...pport to enhance data integrity and system security See the table on the right for jumper settings The default setting is enabled TPM Enable Jumper Settings Jumper Setting Definition Pin 1 2 Enabled D...

Страница 85: ...Connection Speed Indicator Left LED Settings LED Color Definition Off 10 MHz Green 100 MHz Amber 1 GHz 10G LAN Link LEDs LED Settings for X10QBL CT LED Color Definition Off No Connection 10 or 100 Mbp...

Страница 86: ...ore removing or installing components See the tables at right for more information Onboard PWR LED Indicator LED States LED Color Definition Off System Off PWR cable not connected Green System On SAS...

Страница 87: ...s while I SATA ports 2 5 support SATA 2 0 These SATA connectors provide serial link connections which are faster than Parallel ATA connections See the table on the right for pin definitions SAS 3 0 Po...

Страница 88: ...ard Download this file to create a CD DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred Another option is to go to the Supermicro Website at...

Страница 89: ...onitoring program that functions in a command line or web based interface in Windows and Linux operating systems The program monitors system health information such as CPU temperature system voltages...

Страница 90: ...tor 5 Interface Display Screen Remote Control Note The SuperDoctor 5 program and User s Manual can be downloaded from the Supermicro web site at http www supermicro com products nfo sms_sd5 cfm For Li...

Страница 91: ...urer CR2032 Dispose of used batteries according to the manufacturer s instructions Figure 5 8 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER Please handle used batteries carefully Do no...

Страница 92: ...5 36 SUPERSERVER 8048B TR3F C0R3FT User s Manual Notes...

Страница 93: ...dle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a gr...

Страница 94: ...Connect the cable from JF1 on the serverboard to the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow path...

Страница 95: ...C748 tower 4U rackmount chassis is shipped in tower mode and can be immediately used as desktop server If the chassis is to be used in a rack you must rotate the storage module 90 degrees This can be...

Страница 96: ...ule to any component in the chassis 3 Push the storage module release lever This lever unlocks the storage module 4 Grasp the external edges of the storage module and pull the unit from the chassis 5...

Страница 97: ...rations see A B and C below which can then be combined within the three bays to suit the user s needs Example 2 DVDs with 1 HDD or 1 DVD with 2 HDD etc Basic Configurations A Add up to three extra har...

Страница 98: ...ray Release Tabs 3 Push the drive tray toward the front of the chassis Figure 6 6 4 Place the hard drive to the hard drive tray The hard drive can be SAS or SCSI depending on your motherboard The hard...

Страница 99: ...h the rails to a DVD ROM CD ROM floppy drive or other peripheral The rails should fit any standard sized peripherals Figure 6 8 6 Slide the peripheral into the chassis until the tray clicks into place...

Страница 100: ...CSE M35BP mobile rack in order to install hot swappable hard drives The mobile rack replaces the storage module in the chassis For more information on mobile rack installation and use refer to the app...

Страница 101: ...Each rail requires two screws Make sure the arrow on the rail points toward the front of the chassis Figure 6 10 Figure 6 9 Removing the Drive Bay Drive Tray Release Tabs Figure 6 10 Add Storage Modul...

Страница 102: ...airflow for the drive bays Installing Hard Drives 1 Press the release button to extend the drive tray handle 2 Using the handle pull the drive tray out by the handle The drive is hot swappable there a...

Страница 103: ...ving the Dummy Drive Tray Drive Tray SAS SATA or SCSI Hard Drive Figure 6 13 Installing the Hard Drive 6 Insert the hard drive into the chassis To do this a Press the hard drive release button to exte...

Страница 104: ...sis such as PCI cards Installing Add on and Expansion Cards 1 Locate the release tab on the top of the PCI bracket 2 Gently apply pressure in the middle of the release tab to unlock the PCI Slot brack...

Страница 105: ...acket and motherboard To do this slide the PCI card with L bracket into the PCI slot and secure the card to the motherboard 6 Push the PCI bracket release tab down until it locks into place with an au...

Страница 106: ...chassis supports two different air shroud designs one for AMD CPUs and and another for Intel CPUs Installing the Air Shroud 1 Remove the chassis cover 2 Place air shroud in your chassis with the fan...

Страница 107: ...ny connections Replacing a Front Chassis Fan Front Fan Replacement Procedure Figure 6 18 1 Open the chassis cover and determine which fan has failed Because the fans are hot swappable the chassis does...

Страница 108: ...lacing a Rear Chassis Fan Rear Fan Replacement Procedure Figure 6 19 1 Press the rear fan release tab 2 Pull the fan from the chassis top first 3 Place the new fan in the chassis bottom first 4 Push t...

Страница 109: ...power supply models the system automatically switches to the second power supply when the first fails If your system has only one power supply the system shuts down in the unlikely event of a power fa...

Страница 110: ...6 18 SUPERSERVER 8048B TR3F C0R3FT User s Manual Figure 6 20 Removing a Power Supply Press the Release Button 1 2 1 3 Pull the Drive Out Using the Handle...

Страница 111: ...screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured The right frame displays the key legend Above the key legend is an ar...

Страница 112: ...System Date System Time Use this option to change the system date and time using the arrow keys Enter new values through the keyboard and press Enter Press the Tab key to move between fields The date...

Страница 113: ...ions Select the Advanced tab to access the following submenu items Boot Features Boot Configuration Quiet Boot Use this item to select bootup screen display between POST messages and the OEM logo Sele...

Страница 114: ...d to the host adaptor to function as the bootable disk If this item is set to Postponed the BIOS ROM of the host adaptors will only capture Interrupt 19 during bootup from a legacy device The options...

Страница 115: ...State CPU Configuration This submenu displays the following CPU information as detected by the BIOS It also allows the user to configure CPU settings Processor 0 Processor 1 This submenu displays the...

Страница 116: ...tack This feature is used in conjunction with the items Clear MCA VMX Enable SMX and Lock Chipset for Virtualization media support The default setting is Enable Refer to Intel and Microsoft websites f...

Страница 117: ...Direct Cache Access DCA Select Enable to use Intel DCA Direct Cache Access Technology to improve the efficiency of data transferring and accessing The options are Enable and Disable AES NI New Encryp...

Страница 118: ...tem Select SW_ANY to change the P State coordination type for a software program in the system The options are HW_All SW_ALL and SW_ANY CPU C State Control Package C State limit This feature allows th...

Страница 119: ...power consumption The options are Enable and Disable CPU Advanced PM Turning Energy Perf BIAS Energy Perf BIAS Energy Performance Tuning Use this feature to select whether the BIOS of operating system...

Страница 120: ...de a processor will always remain clear during electric tuning The options are Disable and Enable IIO0 Configuration CPU1 SLOT1 PCI E 3 0 X16 Use the items below to configure the PCI E settings for a...

Страница 121: ...he PCI E port specified by the user The options are GEN1 2 5 GT s GEN2 5 GT s GEN3 8 GT s and Auto L SAS0 3 JSAS1 L SAS4 7 JASA2 Use the items below to configure the PCI E settings for a PCI E port sp...

Страница 122: ...cted I O VT d Intel VT for Direct I O VT d Select Enable to use Intel Virtualization Technology support for Direct I O VT d support by reporting the I O device assignments to the VMM Virtual Machine M...

Страница 123: ...data transfer speed for QPI Link connections The default setting is Fast Link Frequency Select Use this feature to select the desired frequency for QPI Link connections The options are 6 4GB s 7 2GB...

Страница 124: ...ory Controller IMC information DDR Speed Use this feature to force a DDR3 memory module to run at a frequency other than what is specified in the specification The options are Auto 1067 1333 1600 1867...

Страница 125: ...he early stage of POST Power On Self Test The options are is Enable and Disable Command 2 Data Tuning Select Enabled to fine tune electrical command paths from the host system to the memory extension...

Страница 126: ...by the motherboard Memory mirroring creates a duplicate copy of the data stored in the memory to enhance data security Sparing This item indicates if memory sparing is supported by the motherboard Me...

Страница 127: ...rleaving Use this feature to select a rank memory interleaving method The options are Auto 1 Way 2 Way 4 Way and 8 Way Demand Scrub Demand Scrubbing is a process that allows the CPU to correct correct...

Страница 128: ...uth Bridge settings USB Configuration The following USB items will display USB Module Version USB Devices Legacy USB Support Available when USB Functions is not Disabled Select Enabled to support lega...

Страница 129: ...chip and displays the following items SATA Controller This item enables or disables the onboard SATA controller supported by the Intel PCH chip The options are Enabled and Disabled Configure SATA as S...

Страница 130: ...0 to 1 set this item to allow the PCH to initialize the device The options are Enabled and Disabled SATA Thermal Throttling Timing Available for SATA Port 0 Port 1 only Use this item to configure the...

Страница 131: ...ice The options are Enabled and Disabled SATA Thermal Throttling Timing Available for SATA Port 0 Port 1 only Use this item to configure the interactive settings for thermal throttling The options are...

Страница 132: ...y and Per Port MMIOH Size PerII0 Use this item to set the MMIO Memory Mapped I O Hub size for each IIO device The options are 0x8_00000000 32GB 0x10_00000000 64GB 0x20_00000000 128GB 0x40_00000000 256...

Страница 133: ...network device The default option for Onboard LAN 1 is PXE and for Onboard LAN 2 is Disabled ACPI Settings High Precision Event Timer Select Enabled to activate the High Precision Event Timer HPET th...

Страница 134: ...wnership Disable Take Ownership and TPM Clear Note The computer will reboot in order to execute the pending commands and change the state of the security device Current Status Information This item di...

Страница 135: ...This item displays the settings of Serial Port 1 COM Change Port 1 Settings This option specifies the base I O port address and the Interrupt Request address of Serial Port 1 COM Select Disabled to p...

Страница 136: ...ow a client machine to be connected to a host machine at a remote site for networking The options are Disabled and Enabled If the item above set to Enabled the following items will become available fo...

Страница 137: ...communication Select 2 Stop Bits if slower devices are used The options are 1 and 2 Flow Control Use this item to set the flow control for Console Redirection to prevent data loss caused by buffer ove...

Страница 138: ...following items will become available for user s configuration SOL COM2 Console Redirection Settings Use this feature to specify how the host computer will exchange data with the client computer which...

Страница 139: ...munication Select 2 Stop Bits if slower devices are used The options are 1 and 2 Flow Control Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer ove...

Страница 140: ...Select the Event Logs tab to access the following submenu items Change SMBIOS Event Log Settings This feature allows the user to configure SMBIOS Event settings Runtime Error Logging Support Select E...

Страница 141: ...nabled to log system boot events The options are Disabled and Enabled MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number from 1 to 255 The defa...

Страница 142: ...the status of an event in the log The following categories are displayed Date Time Error Code Severity 7 5 IPMI Select the IPMI Intelligent Platform Management Interface tab to access the following su...

Страница 143: ...tem event logs upon each system reboot Select No to keep all system event logs after each system reboot The options are No Yes On next reset and Yes On every reset When SEL is Full This feature allows...

Страница 144: ...ed and Static Station IP Address This item displays the Station IP address for this computer This should be in decimal and in dotted quad form i e 192 168 10 253 Subnet Mask This item displays the sub...

Страница 145: ...t the administrator password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long User Password Use this item to set a user pa...

Страница 146: ...the system Boot Mood Select Use this item to configure boot mood select settings for the machine The options are Legacy UEFI and Dual Fixed Boot Order Priorities This option prioritizes the order of b...

Страница 147: ...tion list Delete Driver Option Use this item to select a driver to delete from the boot priority list Delete Driver Option Select the target driver to delete Network Drive BBS Priorities Available whe...

Страница 148: ...he Save and Exit settings for the system Save Changes and Exit When completing the system configuration changes select this option to save the changes and exit from the BIOS setup utility When a dialo...

Страница 149: ...ing the system configuration changes select this option to save the changes and reboot the computer so that the new system configuration settings can take effect Discard Changes and Reset When complet...

Страница 150: ...ettings or select No to abandon optimized defaults Save as User Defaults Select this feature and press Enter to save the current settings as the user s defaults When the dialog box appears asking you...

Страница 151: ...rs are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the corresponding error A 1 BIOS Error Beep Codes Motherboard BI...

Страница 152: ...A 2 SUPERSERVER 8048B TR3F C0R3FT User s Manual Notes...

Страница 153: ...or up to 2 TB of Load Reduced LRDIMM ECC DDR3 1600 1333 1066 MHz speed S D R A M i n a t w o c h a n n e l m e m o r y b u s w i t h m e m o r y s i z e s o f 4GB 8GB 16GB 32GB and 64GB size 1 35V 1...

Страница 154: ...oling Three heavy duty 9 2 cm and three 8 cm cooling fans fan speed controlled by BIOS setting Note The system cooling fans are NOT redundant but are hot plug System Input Requirements AC Input Voltag...

Страница 155: ...1000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe California Best Management Practices Regulations...

Страница 156: ...o perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell suc...

Отзывы: