DVD Drive Installation
The top cover of the chassis must be opened to gain full access to the DVD drive
bay. The 6018R-TD accomodates only slim DVD drives and side mounting brackets
are needed to mount one in the 6018R-TD server.
You must power down the system before installing or removing a DVD drive.
1. With the chassis cover removed, unplug the power and data cables from the
drive you want to remove.
2. Locate the locking tab at the rear of the drive. It will be on the left side of the
drive when viewed from the front of the chassis.
3. Pull the tab away from the drive and push the drive unit out the front of the
chassis.
4. Add a new drive by following this procedure in reverse order. You may hear a
faint *click* of the locking tab when the drive is fully inserted.
5. Remember to reconnect the data and power cables to the drive before replac-
ing the chassis cover and restoring power to the system.
6-5 Power Supply
The SuperServer 6018R-TD has a single 440-480 watt power supply, which is
auto-switching capable. This enables it to automatically sense and operate at a
100v to 240v input voltage.
Power Supply Failure
If the power supply unit fails, the system will shut down and you will need to replace
the unit. Replacement units can be ordered directly from Supermicro.
As there is only one power supply unit in the 6018R-TD, power must be completely
removed from the server before removing and replacing the power supply unit for
whatever reason.
Removing/Replacing the Power Supply
1. First turn the power switch on the control panel off, then unplug the power
cord from the system.
2. Remove the chassis cover as described in Section 6-3).
3. After making a note of all wiring from the power supply to the motherboard,
disconnect them.
4. To remove the failed power supply, remove the screws from the bottom and
rear of the chassis that secure the power supply to the chassis.
5. Pull the power supply out of the chassis (see Figure 6-7).
Installing a New Power Supply
Replace the failed power supply with the exact same model (available from
Supermicro).
1. Carefully insert the new unit into the chassis.
2. Secure it through the bottom and rear of the chassis with the two screws you
removed previously.
3. Reconnect the power cords that you disconnected when removing the power
supply.
4. Replace the top cover of the chassis.
5. Finish by depressing the power button on the server's control panel.
Содержание SUPERSERVER 6018R-TD
Страница 1: ...SUPERSERVER 6018R TD USER S MANUAL 1 0a...
Страница 9: ...1 6 SUPERSERVER 6018R TD User s Manual Notes...
Страница 15: ...2 10 SUPERSERVER 6018R TD User s Manual Notes...
Страница 18: ...3 4 SUPERSERVER 6018R TD User s Manual Notes...
Страница 43: ...5 26 SUPERSERVER 6018R TD User s Manual Notes...
Страница 49: ...6 10 SUPERSERVER 6018R TD Manual Figure 6 7 Removing Replacing the Power Supply...
Страница 72: ...7 44 SUPERSERVER 6018R TD User s Manual Notes...
Страница 74: ...A 2 SUPERSERVER 6018R TD User s Manual Notes...
Страница 77: ...B 4 SUPERSERVER 6018R TD User s Manual Notes...