Chapter 3: System Interface
3-2
3-3
S
UPER
S
ERVER 6018R-TD User's Manual
Information LED States
State Indication
Fast Blinking Red (1x/sec)
Fan Fail
Solid Red
CPU Overheat
Slow Blinking Red (1x/4
sec)
Power Fail
Solid Blue
Local UID Button Depressed
Blinking Blue
IPMI-Activated UID
3-3 Control Panel LEDs
The control panel located on the front of the SC813TS-441CBP chassis has five
LEDs. These LEDs provide you with critical information related to different parts of
the system. This section explains what each LED indicates when illuminated and
any corrective action you may need to take.
Power
Indicates power is being supplied to the system's power supply units. This LED
should normally be illuminated when the system is operating.
3-4 Hard Drive Carrier LEDs
Each drive carrier has two LEDs.
•
Green:
When illuminated, the green LED on the drive carrier indicates drive
activity. A connection to the backplane enables this LED to blink on and off
when that particular drive is being accessed.
•
Red:
The red LED to indicate a drive failure. If one of the drives fails, you should
be notified by your system management software. Please refer to Chapter 6 for
instructions on replacing failed drives.
1
2
Information LED
This LED will be blue when the UID function has been activated. When this LED
flashes red, it indicates a fan failure. When red continuously it indicates an overheat
condition, which may be caused by cables obstructing the airflow in the system or
the ambient room temperature being too warm. Check the routing of the cables
and make sure all fans are present and operating normally. You should also check
to make sure that the chassis covers are installed. Finally, verify that the heatsinks
are installed properly (see Chapter 5). This LED will remain flashing or on as long
as the indicated condition exists.
NIC1
Indicates network activity on LAN1 when flashing.
NIC2
Indicates network activity on LAN2 when flashing.
HDD
Channel activity for all HDDs. This light indicates hard drive activity on the 6018R-
TD when flashing.
Содержание SUPERSERVER 6018R-TD
Страница 1: ...SUPERSERVER 6018R TD USER S MANUAL 1 0a...
Страница 9: ...1 6 SUPERSERVER 6018R TD User s Manual Notes...
Страница 15: ...2 10 SUPERSERVER 6018R TD User s Manual Notes...
Страница 18: ...3 4 SUPERSERVER 6018R TD User s Manual Notes...
Страница 43: ...5 26 SUPERSERVER 6018R TD User s Manual Notes...
Страница 49: ...6 10 SUPERSERVER 6018R TD Manual Figure 6 7 Removing Replacing the Power Supply...
Страница 72: ...7 44 SUPERSERVER 6018R TD User s Manual Notes...
Страница 74: ...A 2 SUPERSERVER 6018R TD User s Manual Notes...
Страница 77: ...B 4 SUPERSERVER 6018R TD User s Manual Notes...