background image

S

UPER

S

ERVER

®

 

 

6018R-TD

USER’S MANUAL

 

 

1.0a

Содержание SUPERSERVER 6018R-TD

Страница 1: ...SUPERSERVER 6018R TD USER S MANUAL 1 0a...

Страница 2: ...said license IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION E...

Страница 3: ...configuring the serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC813TS 441CBP server chassis You should follow the procedures given in this chapter whe...

Страница 4: ...ttons 3 1 Reset 3 1 Power 3 1 3 3 Control Panel LEDs 3 2 Information LED 3 2 NIC1 3 2 NIC2 3 3 HDD 3 3 Power 3 3 3 4 Hard Drive Carrier LEDs 3 3 Chapter 4 Standardized Warning Statements for AC System...

Страница 5: ...essing the Drive Bays 6 5 SATA Drive Installation 6 6 SATA Power Cables 6 7 SATA Backplane 6 7 DVD Drive Installation 6 8 6 5 Power Supply 6 9 Power Supply Failure 6 9 Chapter 7 BIOS 7 1 Introduction...

Страница 6: ...ne RSC RR1U E8 riser card SATA Accessories One SATA backplane BPN SAS 815T Four 3 5 hard drive carriers MCP 220 00075 0B One SATA cable CBL 01801 01 One rail kit consisting of one set each of outer ra...

Страница 7: ...RD L One expansion card may be added to the system with the included riser card See Section 5 6 for details Rear I O Ports The rear I O panel include one COM port a VGA monitor port four USB 2 0 ports...

Страница 8: ...ter Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 235 Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226 3992 Email support supermicro com tw Website www supermicro com tw JLAN2 X10DRD L LT 4 PH...

Страница 9: ...1 6 SUPERSERVER 6018R TD User s Manual Notes...

Страница 10: ...l noise and electromagnetic fields are generated A nearby grounded power outlet is required The box your chassis was shipped in should include two sets of rail assemblies two rail mounting brackets an...

Страница 11: ...onment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated am...

Страница 12: ...onsists of two sections an inner rail that secures directly to the chassis and an outer rail that secures directly to the rack itself Figure 2 2 Identifying the Sections of the Rack Rails right side r...

Страница 13: ...il SCALE 0 500 Secure to the Front of the Rack Secure to the Rear of the Rack Figure 2 3 Assembling the Outer Rails Attach the Two Sections of the Outer Rail Together Figure 2 4 Installing the Outer R...

Страница 14: ...talling the Server into a Telco Rack Installing the Chassis into a Telco rack To install the chassis into a Telco type rack use two L shaped brackets on either side of the chassis four total First det...

Страница 15: ...2 10 SUPERSERVER 6018R TD User s Manual Notes...

Страница 16: ...on the chassis control panel This chapter explains the meanings of all LED indicators and the appropriate re sponse you may need to take 3 2 Control Panel Buttons There are two push buttons located on...

Страница 17: ...this LED to blink on and off when that particular drive is being accessed Red The red LED to indicate a drive failure If one of the drives fails you should be notified by your system management softw...

Страница 18: ...3 4 SUPERSERVER 6018R TD User s Manual Notes...

Страница 19: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 20: ...rtado de traducciones que acompa a a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE S CURIT Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation p...

Страница 21: ...nsure that the protective device is rated not greater than 250 V 20 A 250 V 20 A 250V 20A 250V 20A Warnung Dieses Produkt ist darauf angewiesen dass im Geb ude ein Kurzschluss bzw berstromschutz insta...

Страница 22: ...ngsteilmodulen entfernt wird bevor es auf den Chassisinnenraum zur ckgreift um Systemsbestandteile anzubringen oder zu entfernen Advertencia El sistema debe ser disconnected de todas las fuentes de en...

Страница 23: ...ough the use of a special tool lock and key or other means of security This warning does not apply to workstations Warnung Diese Einheit ist zur Installation in Bereichen mit beschr nktem Zutritt vorg...

Страница 24: ...semblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera inco...

Страница 25: ...pply connection All connections must be removed to de energize the unit Warnung Dieses Ger t kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugef hrt wird m ssen al...

Страница 26: ...ne Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhoud Advertencia La instalacion del equipo...

Страница 27: ...r objects away from the openings in the fan assembly s housing Warnung Die L fter drehen sich u U noch wenn die L fterbaugruppe aus dem Chassis genommen wird Halten Sie Finger Schraubendreher und ande...

Страница 28: ...cia Al instalar el producto utilice los cables de conexi n previstos o designados los cables y adaptadores de CA La utilizaci n de otros cables y adaptadores podr a ocasionar un mal funcionamiento o u...

Страница 29: ...els stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA...

Страница 30: ...uit boards it is important to handle them very carefully see Chapter 4 Also note that the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To pr...

Страница 31: ...LGA 2011 socket First press and release the load lever labeled Open 1st OPEN1st OPEN1st Release the lever labeled Close 1st 2 Press the second load lever labeled Close 1st to release the load plate fr...

Страница 32: ...below to prevent damage to the CPU or other components 1 Unscrew the heatsink screws from the serverboard in the sequence shown below 2 Gently wriggle the heatsink to loosen it from the CPU do not use...

Страница 33: ...ition your power supply must be connected to the 8 pin Processor Power connectors at JPWR2 and JPWR3 Connecting the Control Panel JF1 contains header pins for various front control panel connectors Se...

Страница 34: ...DIMM Installation Processors and their Corresponding Memory Modules CPU Corresponding DIMM Modules CPU 1 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 CPU2 P2 DIMME1 P2 DIMMF1 P2 DIMMG1 P2 DIMMH1 Processor...

Страница 35: ...Supported RSC RR1U E8 pre installed 1x PCI E 3 0 x8 FHHL card Figure 5 5 SUPER X10DRD L Layout 5 7 Serverboard Details Notes indicates the location of pin 1 Jumpers LED indicators not indicated are us...

Страница 36: ...LED Pin Definitions JF1 Pin Definition 15 3 3V 16 Power LED HDD UID LED The HDD LED connection is located on pins 13 and 14 of JF1 Attach a cable to pin 14 to indicate HDD activity Attach a cable to...

Страница 37: ...a hardware reset switch on the computer case Refer to the table on the right for pin definitions Reset Button Pin Definitions JF1 Pin Definition 3 Reset 4 Ground Power Button The Power Button connecti...

Страница 38: ...vice Note UID can also be triggered via IPMI on the serverboard For more information on IPMI please refer to the IPMI user s guide posted on our website http www supermicro com UID Switch Pin Definiti...

Страница 39: ...ate shorts between two pins to change the function of the connector Pin 1 is identified with a square solder pad on the printed circuit board See the diagram at right for an example of jumping pins 1...

Страница 40: ...peed of the connection See the table at right for more information BMC Heartbeat LED A BMC Heartbeat LED is located at LEDM1 on the serverboard When LEDM1 is blinking the BMC is function ing normally...

Страница 41: ...ate the ISO file for your serverboard Download this file to create a CD DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred Another option is t...

Страница 42: ...SMTP services to optimize the efficiency of your operation Note The default User Name and Password for SuperDoctor 5 is admin admin Figure 5 6 SuperDoctor 5 Interface Display Screen Health Information...

Страница 43: ...5 26 SUPERSERVER 6018R TD User s Manual Notes...

Страница 44: ...amage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a groun...

Страница 45: ...to full speed and the Information LED on the control panel will turn on Replace any failed fan at your earliest convenience with the same type and model Accessing the Inside of the System Remove the t...

Страница 46: ...It is recommended that you keep a maintenance log of filter cleaning replacement since its condition will affect the airflow throughout the whole system Accessing the Drive Bays SATA Drives Because of...

Страница 47: ...the backplane with any metal objects and make sure no ribbon cables touch the backplane Also regardless of how many drives are installed all four drive carriers must remain in the chassis to maintain...

Страница 48: ...d operate at a 100v to 240v input voltage Power Supply Failure If the power supply unit fails the system will shut down and you will need to replace the unit Replacement units can be ordered directly...

Страница 49: ...6 10 SUPERSERVER 6018R TD Manual Figure 6 7 Removing Replacing the Power Supply...

Страница 50: ...ot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the lef...

Страница 51: ...ble Power On Self Test POST routine is the memory test As the memory is being tested press the Delete key to enter the main menu of the AMI BIOS setup utility From the main menu you can access the oth...

Страница 52: ...will capture Inter rupt 19 at bootup immediately and allow the drives that are attached to these host adaptors to function as bootable disks If this item is set to Postponed the ROM BIOS of the host a...

Страница 53: ...able Refer to the Intel and Microsoft websites for more information PPIN Control Select Unlock Enable to use the Protected Processor Inventory Number PPIN in the system The options are Unlock Enable a...

Страница 54: ...fficiency Turbo support to turn up CPU core frequency to improve CPU performance without compromising energy efficiency The options are Enable and Disable If the Power Technology option is set to Cust...

Страница 55: ...s feature to set the PCI E bus speed for the slot specified above The options are Gen Generation 1 2 5 GT s Gen Generation 2 5 GT s and Gen Generation 3 8 GT s IIO2 Configuration CPU2 SLOT7 PCI E 3 0...

Страница 56: ...m performance The options are Disable Enable and Auto Isoc Mode Select Enable to enable Isochronous support to meet QoS Quality of Service requirements This feature is especially important for virtual...

Страница 57: ...mplete patrol scrub is performed Use the keyboard to enter a value from 0 to 24 Demand Scrub Demand scrubbing is a process that allows the CPU to correct correctable memory errors found on a memory mo...

Страница 58: ...by the user as an AHCI drive Select RAID to configure a SATA drive specified by the user as a RAID drive The options are IDE AHCI and RAID If the option Configure SATA as is set to AHCI the following...

Страница 59: ...ATA port Model number of drive and capacity Software Preserve Support Port 0 5 Hot Plug Select Enabled to enable hot plugging support for a port specified by the user which will allow the user to repl...

Страница 60: ...system boot The options are Disabled EFI and Legacy SATA sSATA RAID Boot Select Select SATA Controller to boot the system from a SATA RAID device Select sSATA Controller to boot the system from an sS...

Страница 61: ...nboard LAN Option ROM Type Select Enabled to enable Option ROM support to boot the computer using a device installed on the slot specified by the user The options are Legacy and EFI Onboard LAN1 Optio...

Страница 62: ...ature to set the data transmission size in bits for Console Redirec tion The options are 7 and 8 Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select...

Страница 63: ...of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits is odd Select None if you do not want to send a parity bit with your data bits in transmission S...

Страница 64: ...ow control for Console Redirection to prevent data loss caused by buffer overflow It will send a Stop signal to stop sending data when the receiving buffer is full and send a Start signal to start sen...

Страница 65: ...network security The options are Disabled and Enabled 7 4 Event Logs Use this feature to configure event log settings Change SMBIOS Event Log Settings This feature allows the user to configure SMBIOS...

Страница 66: ...press Enter to view the status of an event in the log The following details of each event are displayed Date Time Error Code Severity 7 5 IPMI Use this feature to configure Intelligent Platform Manage...

Страница 67: ...d to the network and request the next available IP address for this computer The options are DHCP and Static Station IP Address This item displays the station IP address for this computer This should...

Страница 68: ...ur system Select No to load the default settings from other sources Key Exchange Key KEK Delete KEK Key Exchange Key Select Yes to confirm deletion of the KEK from the NVRAM Non Volatile RAM Set New K...

Страница 69: ...it boots up The default setting is 1 Boot Mode Select Use this item to select the type of device to be used for system boot The options are Legacy UEFI and Dual Fixed Boot Order Priorities This optio...

Страница 70: ...boot priority list Path for Boot Option Select the device path the file system for the new boot device to use Create After selecting a boot device to add and the path for this new device choose this...

Страница 71: ...king system configuration changes select this option to save all changes made This will not reset reboot the system Discard Changes Select this option and press Enter to discard all the changes you ve...

Страница 72: ...7 44 SUPERSERVER 6018R TD User s Manual Notes...

Страница 73: ...errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the cor responding error Motherboard BIOS Error Beep Codes...

Страница 74: ...A 2 SUPERSERVER 6018R TD User s Manual Notes...

Страница 75: ...oad Reduced DIMMs or 512 GB of ECC RDIMM Registered DIMMs DDR4 2400 2133 1866 1600 memory Note See the memory section in Chapter 5 for details SATA Intel on chip controller for six SATA 3 0 ports RAID...

Страница 76: ...ed USA CUL Listed Canada TUV Certified Germany CE Marking Europe California Best Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing...

Страница 77: ...B 4 SUPERSERVER 6018R TD User s Manual Notes...