5-7 System Fans
Four fans provide cooling for the system.
Figure 5-12. System Fan Placement
Changing a System Fan
1. If necessary, open the chassis while the system is running to determine which
fan has failed. Never run the server for an extended period of time with the
chassis cover open.
2. Power down the system described in Section 5-2.
3. Remove the node drawer from the chassis.
4. Remove the failed fan's power cable from the backplane.
5. Lift the fan housing up and out of the chassis.
6. Push the fan up from the bottom and out of the top of the housing.