SuperServer
2028BT-Hxxx User Manual
3-4
3-4 Drive Carrier LEDs
The chassis includes externally accessible SAS/SATA/NVMe drives. Each drive
carrier displays two LED indicators: an activity indicator and a status indicator. The
status indicator functions in RAID configurations. For non-RAID configurations, it
remains off. See the table below for details.
LED Color
Blinking Pattern Behavior for Device
Activity LED
Blue
Blinking
I/O activity
Blue
Solid On
Idle SAS/NVMe drive installed
Off
Off
Idle or SATA drive
Status LED
Red
Solid On
Failure of drive with RSTe
support
Red
Blinking at 1 Hz
Rebuild drive with RSTe support
Red
Blinking with two
blinks and one stop
at 1 Hz
Hot spare for drive with RSTe
support
Red
On for five
seconds, then off
Power on for drive with RSTe
support
Red
Blinking at 4 Hz
Identify drive with RSTe support
Green
Solid On
Safe to remove NVMe device
Amber
Blinking at 1 Hz
Attention state—do not remove
NVMe device
3-5 Power Supply LEDs
On the rear of the power supply module, an LED displays the status.
•
Solid Green
: When illuminated, indicates that the power supply is on.
•
Solid Amber
: When illuminated, indicates the power supply is plugged in and
turned off, or the system is off but in an abnormal state.
Содержание SuperServer 2028BT-HTR+
Страница 1: ...USER S MANUAL Revision 1 0 SuperServer 2028BT HTR 2028BT HNR 2028BT HNC0R...
Страница 12: ...1 6 SuperServer 2028BT Hxxx Notes...
Страница 58: ...SuperServer 2028BT Hxxx User Manual 5 14 Notes...
Страница 100: ...6 42 SuperServer 2028BT Hxxx User s Manual Notes...
Страница 102: ...SuperServer 2028BT Hxxx A 2 Notes...