10
SuperServer 1029P-NR32R User's Manual
Figure 1-1. Control Panel View
1.4 System Chassis Features
Control Panels
The switches and LEDs located on the control panels are described below. One control panel
is located on the front of the chassis on the right side.
Control Panel Features
Item
Feature
Description
1
Power Button
The main power button is used to apply or remove power from the power supply
to the system. Turning off system power with this button removes the main power
but maintains standby power. To perform many maintenance tasks, you must also
unplug system before servicing.
Note: Before applying power to the system, refer to Section 2.4, "Powering On the
System."
2
Reset Button
The reset button is used to reset the system.
3
LAN LED
Indicates activity from the LAN ports.
4
UID LED
Illuminates when the UID button is activated. Use this to easily identify the system
in a rack environment.
5
Power Fail LED/
Info LED
Indicates a power supply module has failed when solid red. The second power
supply module will take the load and keep the system running but the failed module
will need to be replaced. Refer to Chapter 3 for details on replacing the power
supply. This LED should be off when the system is operating normally.
After the server powers on, this LED will blink at 4Hz until initialization is complete,
upon which time it will turn off and become the Power Fail LED.
1
5
4
3
2