SuperServer 5019P-WT/WTR User's Manual
39
38
Chapter 3: Maintenance and Component Installation
Daughter Cards
An IPMI card can be installed into the motherboard for remote management capabilities. See
the board layout for the location of the daughter board connector.
Motherboard Battery
The motherboard uses non-volatile memory to retain system information when system power
is removed. This memory is powered by a lithium battery residing on the motherboard.
Replacing the Battery
Begin by removing power from the system as described in section 3.1.
1. Push aside the small clamp that covers the edge of the battery. When the battery is
released, lift it out of the holder.
2. To insert a new battery, slide one edge under the lip of the holder with the positive (+)
side facing up. Then push the other side down until the clamp snaps over it.
Note:
Handle used batteries carefully. Do not damage the battery in any way; a damaged
battery may release hazardous materials into the environment. Do not discard a used battery
in the garbage or a public landfill. Please comply with the regulations set up by your local
hazardous waste management agency to dispose of your used battery properly.
Warning:
There is a danger of explosion if the onboard battery is installed upside down (which
reverses its polarities). This battery must be replaced only with the same or an equivalent type
recommended by the manufacturer (CR2032).
OR
Figure 3-3. Installing the Onboard Battery
3.4 Chassis Components
Front Bezel
If your system has an optional bezel attached to the front of the chassis, you will need to
remove it to gain access to the drive bays.
1. Unlock the front of the chassis and then press the release knob.
2.
Carefully remove the bezel with both hands. A filter located within the bezel can be
removed for replacement/cleaning.
It is recommended that you keep a maintenance log to list filter cleaning/replacement dates,
since its condition affects the airflow throughout the whole system.
Hard Drives
Your server may or may not have come with hard drives installed. Up to four (4) 3.5" hard
drives are supported by the chassis.
The SAS/SATA drives are mounted in drive carriers to simplify their installation and removal
from the chassis. (Both procedures may be done without removing power from the system.)
Removing a Hot-Swap Drive Carrier
1. Push the release button on the carrier.
2. Swing the handle fully out.
3. Grasp the handle and use it to pull the drive carrier out of its bay.