FatTwin F619H6-FT User's Manual
36
Replacing the Power Supply
The F414IS4 chassis includes dual 2000 Watt power supplies. This power supply is auto-
switching capable. This enables it to automatically sense and operate at a 100v to 240v input
voltage. An amber light will be illuminated on the power supply when the power is off. An
illuminated green light indicates that the power supply is operating.
The system with the power supply is designed to have a multiple maximum output power
base, on different input ratings. The power ratings available are shown in the table below,
please make sure your system's total power budget is within the maximum output power:
PWS-2K04A-1R Power Ratings
Region
Input Power Source Current Rating Maximum Output Power
North America
100-120V, 50-60Hz
12.0-10.5A
1100W
200-240V, 50-60Hz
11.0-9.8A
2000W
International
100-120V, 50-60Hz
12.0-10.5A
1100W
200-240V, 50-60Hz
10.0-8.3A
1995W
A default interconnected power cord comes with the system and uses a 250VAC, C13 to
C14 connectors with a 14AWG wire and can be used for power strips or racks/PDU with a
200V- 240VAC rating only.
Note:
When required, the alternative power cord should be purchased separately.
Note:
For North American use, a wall-plug 250 VAC, NEMA 6-15P or 6-20P, wire size 14-
16AWG power cord should be used.
Warning! Only the approved power cords or default power cords provided with
the server are supported. Other alternative power cords must be certified and suitably
rated for the use.