background image

FatTwin F619H6-FT User's Manual

22

Figure 2-2. Attaching the Rails to a Rack

Installing the Rails on a Rack

Installing the Rails

1. 

Adjust the length of both rails as described on the previous page.

2. Align the front section of the outer rail with the slots on the front post of the rack. Secure 

the front of the outer rail to the rack with two screws.

3. 

Pull out the rear section of the outer rail, adjusting the length until it fits within the posts 

of the rack. 

4. Align the rear section of the rail with the slots on the rear post of the rack. Secure the 

rear of the outer rail to the rear of the rack with two screws. 

5. Repeat steps 1-4 for the remaining rail.

Содержание FatTwin F619H6-FT

Страница 1: ...USER S MANUAL Revision 1 0 FatTwin F619H6 FT...

Страница 2: ...a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful...

Страница 3: ...Product drivers and utilities https www supermicro com wdl driver Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our support...

Страница 4: ...4 Quick Reference Table 15 Chapter 2 Server Installation 2 1 Overview 17 2 2 Preparing for Setup 17 Choosing a Setup Location 17 Rack Precautions 17 Server Precautions 18 Rack Mounting Considerations...

Страница 5: ...32 Replacing Exhaust Fans 34 Replacing the Power Supply 36 Power Supply Replacement 37 3 3 Motherboard Components 38 Processor and Heatsink Installation 38 The Processor 38 Overview of the Processor...

Страница 6: ...t Windows OS Installation 61 5 2 Driver Installation 63 5 3 SuperDoctor 5 64 5 4 IPMI 64 Chapter 6 UEFI BIOS 6 1 Introduction 65 Starting the Setup Utility 65 6 2 Main Setup 66 6 3 Advanced Setup Conf...

Страница 7: ...B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma super...

Страница 8: ...SAS3 SATA3 HDD BPN SAS3 SCP1T A2 AC10 4 1U Passive CPU Heat Sink with a 17 mm Wide Side Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism for CPU1 SNK P0067PSC 4 1U Passiv...

Страница 9: ...nner chassis wall This guide pin also acts as a stop when a node is fully installed If too much force is used when inserting a node this pin may break off Take care to slowly slide a node in until you...

Страница 10: ...egistered DIMM RDIMM and NVDIMM DDR4 288 pin ECC memory of 2666 2400 2133 MHz in 12 slots per node Chipset C621 chipset Expansion Slots The X11DPFF SN motherboard has the following expansion slots ava...

Страница 11: ...servicing The power button has a built in LED which will turn green when the power is on 2 UID LED When used with a UID compatible motherboard the UID button is used to turn on or off the blue light...

Страница 12: ...ont View Information LED Status Description Continuously on and red An overheat condition has occurred This may be caused by cable congestion Blinking red 1Hz Fan failure check for an inoperative fan...

Страница 13: ...upply Dual 2000 Watt power supplies 2 Rear Fan The chassis has eight rear fans for cooling These are tool less removable Figure 1 3 Chassis Rear View Rear Features The illustration below shows the fea...

Страница 14: ...FAN2 JPW3 JPW2 JPW1 J31 J30 LED3 M 2 HC1 M 2 HC0 JIPMILAN JUSB1 UID VGA COM1 BIOS LEDM1 HDD_LED1 FAILURE_LED1 CPU1 SLOT1 PCI E 3 0 x16 JPCIE4 UID_LED1 USB0 1 3 0 TPM PORT80 JUIDB1 PWR IPMI_LAN X11DPF...

Страница 15: ...SC 8 pin auxiliary power connector for ADP via a cable connected to a power adaptor card JRK1 NVMe RAID Key header JSDCARD1 BMC SD card header M 2 HC0 M 2 HC1 J30 J31 PCI E SATA hybrid M 2 slots M 2 s...

Страница 16: ...2666 DDR4 2133 2666 1 1 2 3 2 3 DMI3 DMI3 P2 P2 USB SPI SPI VGA RJ45 COM DDR4 BMC Boot Flash RMII NCSI RGMII VGA COM PORT Bus S W SYSTEM POWER PCI E X16 PCI E X8 SIOM X16 PCI E X16 G3 PCI E X16 G3 PCI...

Страница 17: ...ease read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where hea...

Страница 18: ...from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep...

Страница 19: ...lf should be grounded Particular attention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury...

Страница 20: ...designed for installation into a Telco post style rack unit Stability Hazard The rack stabilizing mechanism must be in place or the rack must be bolted to the floor before you slide the unit out for...

Страница 21: ...adjusts in length and secures to the rear post of the rack These assemblies are specifically designed for the left and right side of the chassis see Figure 2 1 Adjusting the Rails Each rail assembly h...

Страница 22: ...e outer rail with the slots on the front post of the rack Secure the front of the outer rail to the rack with two screws 3 Pull out the rear section of the outer rail adjusting the length until it fit...

Страница 23: ...ssis Installation Installing the Chassis into a Rack 1 Confirm that the rails are correctly installed on the rack 2 Align the bottom of the chassis with the bottom of the rails 3 Insert the chassis in...

Страница 24: ...ompts 2 After the system has completely shut down carefully grasp the head of the power cord and gently pull it out of the back of the power supply 3 If your system has dual redundant power supplies r...

Страница 25: ...ous page 2 Grasp the node by the handles on either side of the front of the node 3 Carefully pull the node forward and out of the chassis Removing the Node Cover Each node has a removable cover which...

Страница 26: ...ply to fixed 3 5 hard drives Caution Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers For information on recommended HDDs visit the Supermicro website at htt...

Страница 27: ...pply as described in Section 3 1 Remove the node from the chassis and remove the node cover as described previously in this section 2 Press the latch on the HDD tray 3 Shift the tray toward the direct...

Страница 28: ...addition to the node components shown there are eight exhaust fans and two power supplies located in the rear of the chassis body Figure 3 4 Configuration of the Node Eight 3 5 HDDs HDD Backplane Boa...

Страница 29: ...assis and remove the node cover as described previously in this section 2 Remove the the 3 5 hard drive trays from the chassis and release them as described previously 3 Remove the three screws securi...

Страница 30: ...he node cover as described previously in this section 2 Remove the screws securing the power adapter board to the floor of the node and set them aside for later use 3 Lift the power adapter board up a...

Страница 31: ...Cards PCI E Slot Setup The nodes of some F414IS4 chassis models support two low profile PCI E expansion cards To install the low profile expansion cards follow the instructions on the following pages...

Страница 32: ...ting screw which secures the PCI E slot cover in the riser card bracket and set this aside for later use 4 Remove the PCI E slot cover by sliding it sideways and out of the PCI E slot and set this scr...

Страница 33: ...33 Chapter 3 Maintenance and Component Installation 8 6 Figure 3 8 Removing the Riser Card Bracket from the Node...

Страница 34: ...fans These fans are easily removed and must be replaced when they fail Replacing an Exhaust Fan 1 Determine the location of the failed fan 2 Remove the power cord from the rear of the node with the fa...

Страница 35: ...35 Chapter 3 Maintenance and Component Installation Figure 3 10 Removing the System Fans from the Fan Housing Squeeze the Release Tabs...

Страница 36: ...maximum output power PWS 2K04A 1R Power Ratings Region Input Power Source Current Rating Maximum Output Power North America 100 120V 50 60Hz 12 0 10 5A 1100W 200 240V 50 60Hz 11 0 9 8A 2000W Internat...

Страница 37: ...units can be ordered directly from Supermicro see the contact information in the Preface of this manual Changing the Power Supply 1 Power down the system and disconnect the AC power cord on the back o...

Страница 38: ...tall the processor into the CPU socket before you install the CPU heatsink If you buy a CPU separately make sure that you use an Intel certified multi directional heatsink only Make sure to install th...

Страница 39: ...et assembly contains 1 the 81xx 61xx 51xx 41xx 31xx processor 2 CPU heatsink carrier 3 dust cover and 4 CPU socket 3 Dust Cover 4 CPU Socket 1 The 81xx 61xx 51xx 41xx 31xx Processor Note Be sure to co...

Страница 40: ...tsink Module The processor heatsink module PHM contains 1 a passive heatsink 2 a CPU heatsink carrier and 3 The 81xx 61xx 51xx 41xx 31xx processor 1 Passive Heatsink 2 CPU Heatsink Carrier 3 81xx 61xx...

Страница 41: ...GA3647 socket and 4 a back plate These components are pre installed on the motherboard before shipping Processor Socket Assembly W A R N I N G Socket Cover LGA3647 Socket Socket Pins Removing the Dust...

Страница 42: ...in 1 Notch A Notch B and Notch C on the CPU with the corresponding notches on the carrier Once they are aligned carefully insert the CPU into the carrier until you hear a click Once the CPU is properl...

Страница 43: ...ave made a CPU carrier assembly please follow the steps below to mount the assembly onto the heatsink to create the Processor Heatsink Module PHM 1 Place the heatsink upside down with the thermal grea...

Страница 44: ...h the corresponding mounting holes on the socket The PHM will only fit one way If it does not fit correctly remove it and try again 3 Using a T30 size star driver bit tighten eight screws into the mou...

Страница 45: ...M counterclockwise to loosen it from the socket starting with screw marked 4 in the sequence of 4 3 2 1 2 After all eight screws are removed wiggle the PHM gently and pull up to remove it from the soc...

Страница 46: ...hannel One DIMM per Channel Two DIMMs per Channel 4 Gb 8 Gb 1 2 Volts 1 2 Volts RDIMM SRx4 8 GB 16 GB 2666 2666 SRx8 4 GB 8 GB 2666 2666 DRx8 8 GB 16 GB 2666 2666 DRx4 16 GB 32 GB 2666 2666 RDIMM 3Ds...

Страница 47: ...be mixed in the same channel Mixing of LRDIMMs and RDIMMs is not allowed in the same channel across different channels and across different sockets Mixing of non 3DS and 3DS LRDIMM is not allowed in...

Страница 48: ...Sequence 2 CPUs 2 DIMMs CPU1 P1 DIMMA1 CPU2 P2 DIMMA1 2 CPUs 4 DIMMs CPU1 P1 DIMMA1 P1 DIMMD1 CPU2 P2 DIMMA1 P2 DIMMD1 2 CPUs 6 DIMMs CPU1 P1 DIMMC1 P1 DIMMB1 P1 DIMMA1 CPU2 P2 DIMMC1 P2 DIMMB1 P2 DI...

Страница 49: ...power from the system as described in Section 3 1 Follow the memory population sequence in the table above 1 Push the release tabs outwards on both ends of the DIMM slot to unlock it Notches Release T...

Страница 50: ...holder with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in any way a damaged battery may rele...

Страница 51: ...s Two 8 pin 12V power connectors located at JPW1 JPW2 are used to provide main power to your system via power adaptor cards Connect appropriate power cables to JPW1 JPW2 and the power adaptor cards to...

Страница 52: ...in HDD power connectors located at HDD_PWR1 2 provide power to HDD devices Connect appropriate power cables to use HDD power connectors See the table below for pin definitions 8 pin Power HDD_PWR1 2 P...

Страница 53: ...Me SDD Intel RAID Key Pin Definitions Pin Definition 1 Ground 2 3 3V Standby 3 Ground 4 PCH RAID Key 4 pin BMC External I2 C Header A System Management Bus header for IPMI 2 0 is located at JIPMB1 Con...

Страница 54: ...d spatial efficiency The M 2 sockets located on the motherboard support PCI E 3 0 X4 32 Gb s SATA SSD cards in the 2260 2280 and 22110 form factors A Holder B Holder Mount C Card Holder Mount Turn 90...

Страница 55: ...s on the front of the motherboard Figure 4 1 Front Panel I O Port Locations and Definitions Front Panel I O Ports No Description No Description 1 SIOM Super I O Module Slot 5 UID Unit Identifier 2 VGA...

Страница 56: ...dicator section below for LAN LED information Unit Identifier Switch UID LED Indicator A Unit Identifier UID switch located on the front panel and the UID LED UIDLED1 located next to the UID switch on...

Страница 57: ...ia appropriate cables to this slot for PCI E I O support For your system to work properly please use the PCI E devices that are fully compliant with the PCI E standard only Power Switch A power switch...

Страница 58: ...onnector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing...

Страница 59: ...tion hangs Close pins 2 3 to generate a non maskable interrupt signal for the application that hangs Watch Dog must also be enabled in BIOS The default setting is Reset Note When Watch Dog is enabled...

Страница 60: ...Please check your system to resolve the situation Failure LED Indicator LED LED State Definition Failure_LED1 On Red Overheating and or Fan Failure CPLD Heartbeat LED When the CPLD Heartbeat LED locat...

Страница 61: ...upermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive o...

Страница 62: ...the driver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choos...

Страница 63: ...Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or...

Страница 64: ...tem monitoring needs With SuperDoctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Man...

Страница 65: ...F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be c...

Страница 66: ...light System Date or System Time using the arrow keys on the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in Day MM DD YYYY format The time is entered i...

Страница 67: ...OS 67 CPLD Version This item displays the version of the CPLD Complex Programmable Logical Device used in the system Memory Information Total Memory This item displays the total size of memory availab...

Страница 68: ...ect BIOS timing setting may cause the system to malfunction When this occurs restore the setting to the manufacture default settings Boot Feature Quiet Boot Use this feature to select the screen betwe...

Страница 69: ...t capture Interrupt 19 immediately to allow the drives attached to these adaptors to function as bootable devices at bootup The options are Immediate and Postponed Re try Boot When EFI Expansible Firm...

Страница 70: ...r pressing and holding the power button for 4 seconds or longer Select Instant Off to instantly power off the system as soon as the user presses the power button The options are 4 Seconds Override and...

Страница 71: ...IN Control Select Unlock Enable to use the Protected Processor Inventory Number PPIN in the system The options are Unlock Enable and Unlock Disable Hardware Prefetcher Available when supported by the...

Страница 72: ...wer saving mode Select Custom to customize system power settings Select Disabled to disable power saving settings The options are Disable Energy Efficient and Custom When this feature is set to Custom...

Страница 73: ...manufacturer The options are Disable and Enable Hardware PM Power Management State Control Available when Power Technology is set to Custom Hardware P States If this feature is set to Disable hardware...

Страница 74: ...6 Retention state No Limit and Auto CPU T State Control Available when Power Technology is set to Custom Software Controlled T States If this feature is set to Enable CPU throttling settings will be s...

Страница 75: ...ote WViLF SNC Sub NUMA Cluster Select Enable for Sub NUMA Non uniform memory access Cluster support Select Auto for 1 cluster or 2 cluster support depending on the satuts of IMC Integrated Memory Cont...

Страница 76: ...1866 2000 2133 2200 2400 2600 and 2666 Data Scrambling for NVDIMM Select Enable to enable data scrambling for onboard NVDIMM memory to enhance system performance and security The options are Auto Dis...

Страница 77: ...on system power loss an ADR Automatic Diagnostic Repository sequence will be triggered to allow ADR to flush the write protected data buffers in the memory controller and place the DRAM in self refres...

Страница 78: ...r this feature can be edited when the item below ADDDC Sparing is set to Disable UEFI ARM Mirror If this feature is set to Enable mirror mode configuration settings for UEFI based Address Range memory...

Страница 79: ...t Enable for Adaptive Double Device Data Correction ADDDC support which will not only provide memory error checking and correction but will also prevent the system from issuing a performance penalty b...

Страница 80: ...ons are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto MCP0 IIO PCIe Br4 This feature configures the PCI E Bifuraction setting for a PCI E port specified by the user The options are x16 and Auto MCP1 IIO PC...

Страница 81: ...e Disable and Enable Intel VT for Directed I O VT d Intel VT for Directed I O VT d Select Enable to use Intel Virtualization Technology support for Direct I O VT d by reporting the I O device assignme...

Страница 82: ...system performance The options are Enable and Disable Intel VMD Technology Intel VMD for Volume Management Device on CPU1 VMD Config for PStack1 Intel VMD for Volume Management Device Select Enable t...

Страница 83: ...e system Select Enable to use the Intel Volume Management Device Technology for this specific root port The options are Disable and Enable Hot Plug Capable Available when the device is detected by the...

Страница 84: ...is feature to enable PCI E Completion Timeout support for electric tuning The options are Yes No and Per Port South Bridge The following South Bridge information will display USB Module Version USB De...

Страница 85: ...orted by the Intel PCH chip and displays the following items SATA Controller This item enables or disables the onboard SATA controller supported by the Intel PCH chip The options are Enable and Disabl...

Страница 86: ...SATA device installed on the SATA port specified by the user to start a COMRESET initialization The options are Enable and Disable SATA Device Type Use this item to specify if the device installed on...

Страница 87: ...Port 3 Hot Plug Select Enable to support Hot plugging for the device installed on an sSATA port selected by the user which will allow the user to replace the device installed in the slot without shut...

Страница 88: ...G 2 25G and 3G NVMe Firmware Source This feature determines which type of the NVMe firmware should be used in your system The options are Vendor Defined Firmware and AMI Native Support VGA Priority Th...

Страница 89: ...v4 HTTP Support Select Enabled to enable Ipv4 HTTP boot support If this feature is disabled it will not create the Ipv4 HTTP boot option The options are Enabled and Disabled Ipv6 PXE Support Select En...

Страница 90: ...t 1 are Auto IO 3F8h IRQ 4 IO 2F8h IRQ 4 IO 3E8h IRQ 4 and IO 2E8h IRQ 4 Serial Port 2 Configuration Serial Port 2 Select Enabled to enable the onboard serial port specified by the user The options ar...

Страница 91: ...in Console Redirection Make sure that the same speed is used in the host computer as well as the client computer A lower transmission speed may be required for long and busy lines The options are 9600...

Страница 92: ...Legacy OS Redirection Resolution Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support The options are 80x24 and 80x25 Putty KeyPad This feature...

Страница 93: ...and 8 Bits Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select...

Страница 94: ...y Console Redirection after BIOS POST Power On Self Test When this feature is set to Bootloader legacy Console Redirection is disabled before booting the OS When this feature is set to Always Enable l...

Страница 95: ...and busy lines The options are 9600 19200 57600 and 115200 bits per second Flow Control Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow...

Страница 96: ...pendency on other timestamp calculation devices such as an x86 RDTSC Instruction embedded in the CPU The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer The option...

Страница 97: ...list of public keys During system boot the platform firmware uses this trusted public key to verify a digital signature in an attempt to manage and control the security of the platform firmware used i...

Страница 98: ...led be sure to disable EV DFX Device Function On Hide support for the system to work properly EV DFX is under IIO Configuration in the Chipset North Bridge submenu 2 For more information on TPM please...

Страница 99: ...nable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Erasing Settings Erase Event Log Available when the item SMBIOS Event Log is set to Enabled Se...

Страница 100: ...vent Count Increment Available when the item SMBIOS Event Log is set to Enabled Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW M...

Страница 101: ...information will display BMC Firmware Revision This feature indicates the firmware revision of the BMC Base board Management Controller used in your system IPMI Status This feature indicates IPMI sta...

Страница 102: ...ault setting is Failover IPMI Network Link Status This item displays the IPMI Network Link status The default setting is Dedicated LAN Configuration Address Source This feature displays the source of...

Страница 103: ...ss VLAN Select Enabled for IPMI VLAN support The options are Disabled and Enabled If the item above VLAN is set to Enabled the following item will be available VLAN ID Use this feature to set the VLAN...

Страница 104: ...e length of the password should be from 3 characters to 20 characters long User Password Use this feature to set the user password which is required to enter the BIOS setup utility The length of the p...

Страница 105: ...nable Compatibility Service Module CMS which will support Legacy BIOS through UEFI to enhance system performance The options are Enabled and Disabled Key Management Provision Factory Default Keys Sele...

Страница 106: ...Signatures for the system These values also indicate the size the keys numbers and the key source of the Authorized Signatures The options are Set New and Append Secure Boot Variable Size Key Key Sou...

Страница 107: ...t from an EFI OS when the Legacy OS fails The options are Enabled and Disabled Fixed Boot Order Priorities This feature prioritizes the order of a bootable device from which the system will boot Press...

Страница 108: ...ate After the name and the file path for the boot option are set press Enter to create the new boot option in the boot priority list Add New Driver Option Use this feature to select a new driver to ad...

Страница 109: ...the boot priority list Delete Drive Option Select the target boot driver to delete from the boot priority list Hard Disk Drive BBS Priorities Boot Option 1 5 Network Drive BBS Priorities Boot Option...

Страница 110: ...er Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility...

Страница 111: ...Defaults To set this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set th...

Страница 112: ...re those which will not allow the system to continue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually...

Страница 113: ...com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnost...

Страница 114: ...assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These w...

Страница 115: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 116: ...dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het...

Страница 117: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 118: ...del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l install...

Страница 119: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 120: ...ls aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Warnu...

Страница 121: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 122: ...una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s un...

Страница 123: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 124: ...bevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All conne...

Страница 125: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 126: ...rtencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circ...

Страница 127: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 128: ...elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled according...

Страница 129: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 130: ...ornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient touj...

Страница 131: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSA Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 132: ...code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto utili...

Страница 133: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 134: ...DD s These are SATA3 but can be mixed with SAS3 if an optional add on card is in a node PCI Expansion Slots The X11DPFF SN motherboard has the following expansion slots One PCI E 3 0 x16 slot supporte...

Страница 135: ...4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 CNS14336 1 CNS13438 GB4943 1 2011 GB9254 2008 Class A and GB17625 1 2012 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canad...

Страница 136: ...ge The recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system...

Страница 137: ...I BIOS recovery using a USB attached device follow the instructions below 1 Using a different machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DVD...

Страница 138: ...you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed wit...

Страница 139: ...to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built in...

Страница 140: ...rrupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power supp...

Отзывы: