SC823M Chassis Series

USER’S MANUAL 

 

1.0a

SC823MTQ-R700LPB

SC823MTQ-R700UB

SC823MTQC-R802LPB

SC823MTQC-R802WB

Содержание CSE-823MTQ-R700LPB

Страница 1: ...SC823M Chassis Series USER S MANUAL 1 0a SC823MTQ R700LPB SC823MTQ R700UB SC823MTQC R802LPB SC823MTQC R802WB...

Страница 2: ...DWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA Any disputes arising between manuf...

Страница 3: ...2U chassis is a short depth chassis with a unique and highly optimized design The chassis is equipped with three 3 5 hot swappable hard drives and a redundant 700W or 800W high efficiency power suppl...

Страница 4: ...luding the fans bays airflow shields and other components Chapter 4 System Interface Refer to this chapter for details on the system interface which includes the functions and information provided by...

Страница 5: ...v Preface Notes...

Страница 6: ...ent Installation 2 8 Restricted Area 2 9 Battery Handling 2 10 Redundant Power Supplies 2 12 Backplane Voltage 2 13 Comply with Local and National Electrical Codes 2 14 Product Disposal 2 15 Hot Swap...

Страница 7: ...5 12 Expansion Card Setup in UIO WIO Model Chassis 5 13 5 7 Installing the Air Shroud 5 15 5 8 Checking the System Airflow 5 16 5 9 Completing the Installation 5 17 5 10 System Fans 5 18 5 11 Power S...

Страница 8: ...ocking Tabs 6 5 Releasing the Inner Rail 6 5 Installing The Inner Rails on the Chassis 6 6 Installing the Outer Rails on the Rack 6 7 Standard Chassis Installation 6 8 Appendix A SC823M Power Supply S...

Страница 9: ...ppable drive bays 1 2 Chassis Features Please visit the following link for the latest shipping lists and part numbers for your particular chassis model http www supermicro com SC823M Chassis Model HDD...

Страница 10: ...e Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro...

Страница 11: ...ust be mailed when service is complete For faster service RMA authorizations may be requested online http www super micro com support rma Whenever possible repack the chassis in the original Supermicr...

Страница 12: ...SC823M Chassis Manual 1 4 Notes...

Страница 13: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 14: ...e los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el texto...

Страница 15: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Страница 16: ...s Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de brancher le sy...

Страница 17: ...ert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrientes de...

Страница 18: ...Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chass...

Страница 19: ...nentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enle...

Страница 20: ...s Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar...

Страница 21: ...stallation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m gli...

Страница 22: ...quivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte...

Страница 23: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 24: ...entes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour supprimer tout...

Страница 25: ...ero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors de la maintenanc...

Страница 26: ...l codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Backplane W...

Страница 27: ...re install conform ment aux normes lectriques nationales et locales Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften Warnung Di...

Страница 28: ...ing parts Keep away from moving fan blades The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in the f...

Страница 29: ...s destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soien...

Страница 30: ...ann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle anderen ele...

Страница 31: ...utres appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bi...

Страница 32: ...2 20 SC823M Chassis Manual Notes...

Страница 33: ...models your chassis may include one slim DVD ROM and one slim COM port USB tray For the latest chassis components visit our website at http www supermicro com Backplane Each SC823M chassis comes with...

Страница 34: ...redundant and hot swappable Air Shroud Air shrouds are shields usually plastic that funnel air directly to where it is needed Always use the air shroud included with your chassis 3 3 Where to get Repl...

Страница 35: ...ted on the front of the chassis in the upper left hand corner The illustrations below are for reference only and do not indicate specific component placement Figure 4 1 Control Panel Buttons and LED D...

Страница 36: ...m Turning off system power with this button removes the main power but keeps the standby power Therefore you must unplug system before servicing 4 3 Control Panel LEDs The control panel located on the...

Страница 37: ...ive fan Blinking red 0 25Hz Power failure check for a non operational power supply Solid blue Local UID has been activated Use this function to locate the server in a rack mount environment Blinking b...

Страница 38: ...a green LED When illuminated this green LED on the front of the SAS 3 SATA drive carrier indicates drive activity A connection to the SAS 3 SATA backplane enables this LED to blink on and off when th...

Страница 39: ...etting up your chassis 5 2 Removing Power from the System Removing Power 1 Power down the system by using the operating system and following the on screen prompts 2 After the system has shut down gras...

Страница 40: ...on 5 2 2 Remove the two screws holding the chassis in place 3 Slide the cover toward the rear of the chassis and lift the cover from the unit Figure 5 1 Removing the Chassis Cover Warning Except for s...

Страница 41: ...s which are hot swappable and can be removed from the chassis without powering down the system Removing Hard Drive Carriers from the Chassis 1 Press the release button on the drive carrier This extend...

Страница 42: ...talling a Hard Drive to the Hard Drive Carrier 1 Remove the screws securing the dummy drive to the carrier 2 Remove the dummy drive from the carrier Warning Except for short periods of time while swap...

Страница 43: ...ting holes in the drive align with those in the carrier 4 Secure the hard drive to the carrier by tightening all six screws 5 Place the drive carrier into the drive bay of the chassis Make sure to clo...

Страница 44: ...drive tray DVD ROM drive and USB COM port unit Removing the Hard Drive Tray 1 Power down the system and remove the power cords from the rear of the power supplies as described in Section 5 2 Remove th...

Страница 45: ...tem and remove the power cords from the rear of the power supplies as described in Section 5 2 Remove the chassis cover as described in Section 5 3 2 Locate and remove the screws holding the DVD ROM U...

Страница 46: ...on that came with your motherboard Become familiar with component placement requirements and precautions 2 Power down the system and remove the power cords from the rear of the power supplies as descr...

Страница 47: ...board mounting holes should have matching chassis standoffs If there are additional standoffs in the chassis that are not used by the motherboard remove them Do not allow extra standoffs to remain in...

Страница 48: ...10 Figure 5 10 Installing the Motherboard 7 Connect the cables between the motherboard backplane chassis front pan el and power supply as needed Also the fans may be temporarily removed to allow acces...

Страница 49: ...he rear of the hard drive tray and set them aside for later use 4 Lift the two latches securing the backplane 5 Pull the top of the backplane away from the hard drive tray at a slight angle then lift...

Страница 50: ...ver as described in Section 5 3 2 Confirm that each expansion card you are installing includes a standard L bracket 3 Disconnect the power supply and lay the chassis on a flat surface 4 Remove the scr...

Страница 51: ...the other accommodates the three low profile expansion cards 2 Power down the system and remove the power cords from the rear of the power supplies as described in Section 5 2 Remove the chassis cover...

Страница 52: ...the two screws previously set aside 10 Plug the power cords into the rear of the power supplies replace the chassis cover and power up the system Figure 5 14 Installing Expansion Cards in a UIO WIO Ch...

Страница 53: ...1 Power down the system and remove the power cords from the rear of the power supplies as described in Section 5 2 Remove the chassis cover as described in Section 5 3 2 Each air shroud includes perfo...

Страница 54: ...ting the airflow through the chassis Pull all excess cabling out of the airflow path or use shorter cables For the SC823M chassis it is recommended that cables run beside the power supply as much as p...

Страница 55: ...ion 1 If your chassis is equipped with a DVD ROM drive install the DVD ROM drive unit and connect the DVD ROM drive to the motherboard 2 Install the hard drive tray The hard drive tray includes a SAS...

Страница 56: ...running to determine which fan needs replacing Never run the server for an extended period of time with the chassis open 2 Power down the system and remove the power cords from the rear of the power...

Страница 57: ...g sure the arrows on the top of the fan indicating air direction point in the same direc tion as the arrows on the other fans Each fan includes rubber feet to reduce vibrations Always use all four fee...

Страница 58: ...ed without powering down the system Replacement units can be ordered directly from Supermicro at http www supermicro com 5 11 Power Supply The SC823M chassis includes a redundant power supply It is no...

Страница 59: ...erboard backplane and other components Also remove both power supplies 3 Locate the power distributor between the power supply and the fan row 4 Remove the two screws securing the power distributor to...

Страница 60: ...SC823M Chassis Manual 5 22 Notes...

Страница 61: ...agnetic fields are generated You will also need it placed near a grounded power outlet The box your chassis was shipped in should include two sets of rail assemblies two rail mounting brackets and the...

Страница 62: ...cause the rack to become unstable General Server Precautions Review the electrical and general safety precautions that came with the com ponents you are adding to your chassis Determine the placement...

Страница 63: ...possible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Relia...

Страница 64: ...a rack between 26 5 and 36 4 deep Identifying the Sections of the Rack Rails The chassis package includes two rail assemblies in the rack mounting kit Each assembly consists of three sections An inner...

Страница 65: ...ulled out for servicing Releasing the Inner Rail Use the procedure below to release the inner rails from the outer rails Releasing Inner Rail from the Outer Rails 1 Identify the left and right outer r...

Страница 66: ...entified 2 Place the inner rail firmly against the side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of...

Страница 67: ...the outer rail 3 Hang the hooks of the front of the outer rail onto the slots on the front of the rack If necessary use screws to secure the outer rails to the rack as illustrated above 4 Pull out th...

Страница 68: ...ils as illustrated above 2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis h...

Страница 69: ...6 9 Chapter 6 Rack Installation Figure 6 8 Completed Chassis Installation Figure 6 7 Installing the Chassis into a Rack...

Страница 70: ...SC823M Chassis Manual 6 10 Notes...

Страница 71: ...ur chassis system SC823MTQ R700LPB and SC823MTQ R700UB 700W Redundant MFR Part PWS 702A 1R Rated AC Voltage 100 240 Vac 50 60 Hz 10 4 Amp 5 V Standby Current 4 A 12 V Current 57 A SC823MTQC R802LPB an...

Страница 72: ...SC823M Chassis Manual A 2 Notes...

Страница 73: ...ing their pins Put the card and peripherals back into their antistatic bags when not in use B 2 General Safety Guidelines Always disconnect power cables before installing or removing any components fr...

Страница 74: ...SAS Port 0 8 J7 SAS Port 1 9 J6 SAS Port 2 B 4 Rear Connector Locations The following connectors are on the side of the backplane that faces the rear of the chassis They are marked by silk screen lab...

Страница 75: ...Connector The sideband connector is designated JP51 For SES 2 to work properly you must connect an 8 pin sideband cable to JP51 Sideband Connector Pin Definition Pin Definition 2 SDataIn SGPIO Data In...

Страница 76: ...used to choose between optional settings Jumpers create shorts between two pins to change the function of the connector Pin 1 is identified with a square solder pad on the printed circuit board Note...

Страница 77: ...ndicators Rear LED Indicator Hard Drive Activity and Failure LEDs D12 SCA 0 Activity LED Connected to HDD D13 SCA 1 Activity LED Connected to HDD D14 SCA 2 Activity LED Connected to HDD D5 SAS 0 Failu...

Страница 78: ...B 6 SC825M Chassis Manual Notes...

Страница 79: ...touching their pins Put the card and peripherals back into their antistatic bags when not in use C 2 General Safety Guidelines Always disconnect power cables before installing or removing any componen...

Страница 80: ...Port 0 8 J7 SAS Port 1 9 J6 SAS Port 2 C 4 Rear Connector Locations The following connectors are on the side of the backplane that faces the rear of the chassis They are marked by silkscreen labels J...

Страница 81: ...nd Connector The sideband connector is designated JP51 For SES 2 to work properly you must connect an 8 pin sideband cable to JP51 Sideband Connector Pin Definition Pin Definition 2 SDataIn SGPIO Data...

Страница 82: ...used to choose between optional settings Jumpers create shorts between two pins to change the function of the connector Pin 1 is identified with a square solder pad on the printed circuit board Note...

Страница 83: ...ndicators Rear LED Indicator Hard Drive Activity and Failure LEDs D12 SCA 0 Activity LED Connected to HDD D13 SCA 1 Activity LED Connected to HDD D14 SCA 2 Activity LED Connected to HDD D5 SAS 0 Failu...

Страница 84: ...reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products fo...