Super C9Z490-PG/-PGW User's Manual
78
PS Current Threshold1
Enter a value for PS Current Threshold1. The range is 0-512. The default is
80
.
PS Current Threshold2
Enter a value for PS Current Threshold2. The range is 0-512. The default is
20
.
PS Current Threshold3
Enter a value for PS Current Threshold3. The range is 0-512. The default is
4
.
PS3 Enable
This feature enables PS3. The options are Disabled and
Enabled
.
PS4 Enable
This feature enables PS4. The options are Disabled and
Enabled
.
IMON Slope
Enter a value for IMON Slope. The range is 0-200. The default is
0
.
IMON Offset
Enter a value for IMON Offset. The range is 0-63999. The default is
0
.
IMON Prefix
Use this feature to set the prefix value as a positive (+) or a negative (-). The
options are “
+
” and “-”.
VR Current Limit
Enter a value for the voltage regulator current limit, with each whole number equat-
ing to 1/4A (i.e., 400 = 100A). Enter 0 for Auto.
VR Voltage Limit
Enter a value (in mV) for the voltage regulator voltage limit. The range is 0-7999.
Enter 0 for Auto.
Intersil VR Command
This feature enables Intersil VR Command to fix VR C-state issues. The options are
Disabled
, Send for IA/GT rails, and Send for IA/GT/SA rails.