background image

 

- 7 - 

RDO1 C 

GENERAL FITTING REQUIREMENTS 

 

4.

 

LEFT OR RIGHT HAND END INSTALLATION 

Your  opener  has  been  factory  set  to  be  installed  on  the  right  hand  end  of  your  door

  (when  viewed 

from  inside  the  garage  looking  out)  If  you  will  be  installing  your  Opener  to  the  right  hand  side  of  then 

ignore the instructions outlined in Point 5. If the left hand side is your selected side for installation then 

you must carry out the procedure outlined in Point 5

 

5.

 

CONVERTING OPENER FROM RIGHT HAND TO LEFT HAND INSTALLATION 

        Locate the red and black motor wires. 

Fig 6

 The standard connection (Black to Black and Red to Red) must 

be reversed. Unplug the wires at the connectors and reverse them so that they are connected Red to Black 

and Black to Red. You can now proceed to step 1 of the Installation Instructions. 

 

Fig 6                                                                                        Fig 7 

6.

 

CONTROL BOX   

Mount the control box on a smooth flat surface. The area must be  completely free of exposure to water, 

either direct (rain, garden hose, sprinklers etc) or indirect (seepage either through or down the internal face 

of the wall). The control box contains sensitive electronics which will sustain damage as a result of 

any 

water  intrusion.  Water  damaged  electronics  are  not  covered  under  the  terms  of  the  opener  warranty. 

Important Note: The control box is not water proof!

 

 

7.

 

VOLTAGE SELECTION (For non 240 volt markets only) 

For  certain  markets  your  RDO1  Opener  will  have  been  fitted  with  a 

switch  able  dual  voltage 

transformer. All transformers have been factory pre-set to suit a 220~240 volt power supply

. If your 

local  power  supply  is  110~115  volt  you  will  be  required  to  switch  the  transformer  power  supply  leads 

inside  the  Control  Box  as depicted  in 

Fig  7

. To switch the power supply leads,  remove the  Control  Box 

cover. Locate and un-plug the plastic connectors marked “240V” (Black and Brown coloured wires) and 

plug-in to the connectors marked “115V” (Black and Blue) coloured wires). The switch to 115 volts is now 

complete. 

 

 

 

 

 

Содержание RDO1 C

Страница 1: ...801 001 01 C...

Страница 2: ...wall switch or wall mounted transmitter in a location position where the garage door is visible and OUT OF REACH OFF CHILDREN 8 The Garage door must be WELL BALANCED Sticking binding or out of balance...

Страница 3: ...once a month Refer to installation manual for further instructions SECURITY CODE STORE The opener uses state of the art technology in storing your selected Transmitter Security Code Up to 6 different...

Страница 4: ...4 RDO1 C OPERATING CONTROLS...

Страница 5: ...l push button 10 RADIO RECEIVER processes the signal from the hand held transmitter 11 AUTO COURTESY LIGHT is activated automatically each time the opener commences an open or close cycle and remains...

Страница 6: ...the operation of the door The door must be well balanced and operate smoothly and freely When opened to between 900 1200mm from the floor and released the door should remain in one fixed position and...

Страница 7: ...ce The area must be completely free of exposure to water either direct rain garden hose sprinklers etc or indirect seepage either through or down the internal face of the wall The control box contains...

Страница 8: ...asily once the full weight of the door is imparted on the prop The prop must be strong enough to sustain the full weight of the door but at the same time have enough padding that it will not damage th...

Страница 9: ...g bracket may need to be re positioned in order that the U Bolt holes align Fig 12 Fully insert the specially supplied U bolt through the Drive Unit and Wall Bracket slots Affix and firmly tighten the...

Страница 10: ...e Close Limit Cam accordingly 3 5 Slightly re tighten the 3 Cam Locking Screws Fig 2 3 6 Pull the Red Lock Release Chord to engage the drive and the Opener is ready to be used in automatic mode once t...

Страница 11: ...pens and closes to the required positions If not then re adjust the Open and or Close Limit Cams accordingly 7 3 Once finally adjusted firmly tighten the 3 Limit Cam Locking Screws and refit the Limit...

Страница 12: ...he door is opening push down firmly on the bottom rail of the door from the inside 10 3 The door should stop without having to exert excessive force 10 4 If excessive force is required to stop the doo...

Страница 13: ...ON To enable the auto close function switch dip switch Number 2 to the ON position IMPORTANT NOTE The fitment of PE beams is mandatory once the auto close function has been enabled The Auto Close will...

Страница 14: ...r Transmitter is damaged or broken Transmitter Code has not been programmed into the receiver Control Box antenna wire not extended Battery flat Try to operate the door with an alternative transmitter...

Страница 15: ...15 RDO1 C CONTROL BOX MOUNTING TEMPLATE...

Отзывы: