RDO1 C 

OPERATING CONTROLS 

 

1.

 

PHOTO BEAM ENABLE DIP SWITCH.

 

2.

 

AUTO CLOSE ENABLE DIP SWITCH.

 

3.

 

AUTO CLOSE DELAY DIP SWITCHES 

are used to adjust the time to auto close. 

4.

 

SAME AS ABOVE

 

5.

 

TRANSMITTER CODE BUTTON 

used for storing or erasing the transmitter button code 

6.

 

DOWN FORCE SCREW

 is used to change the force pressure required to make the door DOWN, if the 

door encounters an obstruction. 

7.

 

UP  FORCE  SCREW

  is  used  to  change  the  force  pressure  required  to  make  the  door  UP,  if  the  door 

encounters an obstruction. 

8.

 

CODE LED

 signals the stages of the transmitter code learning process 

9.

 

OUTPUT TERMINALS 

used for connection of photo safety beams or external push button. 

10.

 

RADIO RECEIVER 

processes the signal from the hand held transmitter. 

11.

 

AUTO COURTESY LIGHT

 is activated automatically each time the opener commences an open or close 

cycle and remains on for approx 3 minutes 

12.

 

OPEN LIMIT CAM

 is used to adjust the open limit stop position. (Refer to installation manual for correct 

use) 

13.

 

CLOSE  LIMIT  CAM

  is  used  to  adjust  the  close  limit  stop  position.  (Refer  to  installation  manual  for 

correct use.) 

14.

 

OPEN LIMIT MICRO SWITCH

 is used to stop door in the fully open position. 

15.

 

CLOSE LIMIT MICRO SWITCH

 is used to stop the door in the fully closed position. 

16.

 

ENGAGE/DISENGAGE LEVER

. Alternatively engages/disengages opener from the door. 

17.

 

EXTERNAL PUSH BUTTON 

alternatively opens, closes or stops the door when activated. 

18.

 

VOLTAGE SELECTION TERMINALS

 switches the input voltage between 115 and 240 volts

 

 

Содержание RDO1 C

Страница 1: ...801 001 01 C...

Страница 2: ...wall switch or wall mounted transmitter in a location position where the garage door is visible and OUT OF REACH OFF CHILDREN 8 The Garage door must be WELL BALANCED Sticking binding or out of balance...

Страница 3: ...once a month Refer to installation manual for further instructions SECURITY CODE STORE The opener uses state of the art technology in storing your selected Transmitter Security Code Up to 6 different...

Страница 4: ...4 RDO1 C OPERATING CONTROLS...

Страница 5: ...l push button 10 RADIO RECEIVER processes the signal from the hand held transmitter 11 AUTO COURTESY LIGHT is activated automatically each time the opener commences an open or close cycle and remains...

Страница 6: ...the operation of the door The door must be well balanced and operate smoothly and freely When opened to between 900 1200mm from the floor and released the door should remain in one fixed position and...

Страница 7: ...ce The area must be completely free of exposure to water either direct rain garden hose sprinklers etc or indirect seepage either through or down the internal face of the wall The control box contains...

Страница 8: ...asily once the full weight of the door is imparted on the prop The prop must be strong enough to sustain the full weight of the door but at the same time have enough padding that it will not damage th...

Страница 9: ...g bracket may need to be re positioned in order that the U Bolt holes align Fig 12 Fully insert the specially supplied U bolt through the Drive Unit and Wall Bracket slots Affix and firmly tighten the...

Страница 10: ...e Close Limit Cam accordingly 3 5 Slightly re tighten the 3 Cam Locking Screws Fig 2 3 6 Pull the Red Lock Release Chord to engage the drive and the Opener is ready to be used in automatic mode once t...

Страница 11: ...pens and closes to the required positions If not then re adjust the Open and or Close Limit Cams accordingly 7 3 Once finally adjusted firmly tighten the 3 Limit Cam Locking Screws and refit the Limit...

Страница 12: ...he door is opening push down firmly on the bottom rail of the door from the inside 10 3 The door should stop without having to exert excessive force 10 4 If excessive force is required to stop the doo...

Страница 13: ...ON To enable the auto close function switch dip switch Number 2 to the ON position IMPORTANT NOTE The fitment of PE beams is mandatory once the auto close function has been enabled The Auto Close will...

Страница 14: ...r Transmitter is damaged or broken Transmitter Code has not been programmed into the receiver Control Box antenna wire not extended Battery flat Try to operate the door with an alternative transmitter...

Страница 15: ...15 RDO1 C CONTROL BOX MOUNTING TEMPLATE...

Отзывы: