- 14 -
RDO1 C
TROUBLE SHOOTING GUIDE
SYMPTOM
POSSIBLE CAUSES
REMEDY
Door will not operate
Mains power not turned on
Door is obstructed
Turn on mains power
Remove obstruction
Door is locked or motor
jammed
Mechanical door lock has been engaged
Unlock door
Inspect door and remove jam
Door will not reverse on
hitting an object
Safety Obstruction Force setting is too high
and may require adjustment.
Refer
to
Installation
instructions, - Items 8~10
Door moves downwards
and
reverses
itself
upwards
Safety Obstruction Force setting is too light
and may require adjustment.
Adverse weather conditions (wind or cold)
causing door to stiffen and become tight.
Possible obstruction under door
Refer
to
Installation
Instructions – Items 8 ~ 10
Door operates from drive
unit but not from hand
transmitter
Transmitter is damaged or broken
Transmitter Code has not been programmed
into the receiver
Control Box antenna wire not extended
Battery flat.
Try to operate the door with an
alternative transmitter
Refer to installation instruction
Item 5.
Locate and extend aerial wire
Replace battery(12V)
Door does not close fully
Limit micro switch incorrectly adjusted
Re-adjust limit switch - Refer
Installation Instruction Item 3
Lights malfunction
globe blown
Replace
with
24VDC/3W
globe
Door Stops on Upward
cycle before reaching the
fully open position
Door may be obstructed.
Door springs may have lost tension
Safety
Obstruction
Force
may
need
adjustment
Disengage Opener and check
door for free movement
Call serviceman to affect
repairs
Refer
Section
8~10
of
Installation manual.
Auto close not working
P.E. Beam faulty or wiring broken
P.E. Beam obstructed
Auto close time not set
Repair P.E. or broken wire
Remove obstruction from the
path of beam.
Refer to installation inst. -
Items 13 & 14.