NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Combustible materials may project beyond the sides of the fire-

place opening as long as they are kept within the shaded areas 

illustrated  here.

Hearth Extension

 - A hearth extension is not required with this appliance. If a hearth extension is 

used, do not block the lower control compartment door. Any hearth extension used is for appearance 

only and does not have to conform to standard hearth extension installation requirements.

Wall Finishes / Surrounds / Mantels

Note: 

Combustible wall finish materials and/or surround materials must not be allowed to encroach 

the area defined by the appliance front face (black sheet metal). 

Never allow combustible materials 

to be positioned in front of or overlapping the appliance front face.

 See 

Figure 57 on Page 31

.

Non-combustible materials, such as surrounds and other appliance trim, may be installed on the 

appliance front face with these exceptions: they must not cover any portion of the removable glass  

panel or louvers. 

Vertical installation clearances to combustible mantels vary according to the depth of the mantel.  

See 

Figure 8

. Mantels constructed of non-combustible materials may be installed at any height 

above the appliance opening; however, do not allow anything to hang below the hood.

MINIMUM CLEARANCES TO COMBUSTIBLES

Top of 

Appliance

inches (millimeters)

Figure 8 - 

Minimum Mantel Clearances

Combustible Materials 

Allowed In Shaded 

Area “Safe Zone”

Combustible Walls 

shown in dark gray

Minimum Distance to Unprotected Side Wall

Top View of 

Fireplace

At 14" minimum 

side wall clearance, 

a combustible wall 

can project to any 

length.

Protected wall shown in white

Inches (millimeters)

Figure 10

At 8-1/4" side 

wall clearance, a 

combustible wall 

can project 12"

Hood

Mantel Depth

4 (102)

2

(51)

4

(102)

6

(152)

8

(203)

10

(254)

12

(305)

6 (152)

10 (254)

14 (356)

12 (305)

8 (203)

5 (127)

8-1/4

(209)

14

(356)

12 (305)

19 

(483)

 45o

MINIMUM CLEARANCES

 Inches (millimeters)

Back

1/2 (13)

0 (0) Spacers

Sides

1/2 (13)

0 (0) Spacers

Top Spacers

0 (0)

Floor

0 (0)

Bottom of Appliance 

To Ceiling

64 (1626)

Vent

3 (76) 

Top 

*

1 (25.4) 

Sides & Bottom

SERVICE CLEARANCES 

Feet (meters)

Front

3 ft. (0.9 m)

Table 8

Shelf Above Fireplace With Rear Venting

Do not insulate the

space between the

appliance and the

area above it.

Shelf Height

(

see table)

*Shelf Height

(

see table)

Do not insulate the

space between the

appliance and the

area above it.

Shelf Above Fireplace With Top Venting

Figure 9 - 

Shelf Height Minimum Clearances

Model No.

Combustible Shelf Height - Inches (millimeters)

Top Vent - with One 90 Degree Elbow

Rear Vent - Straight Out the Back

Secure Vent

Secure Flex

(flex elbow)

Secure Vent

Secure Flex

SSDVT-3328

*

44-1/8

 (1121)

*45-7/8 (1165)

N/A

N/A

SSDVR-3328

N/A

N/A

33 1/4 (845)

33 1/4 (845)

* Includes 3” clearance to combustibles (required above vent components)

*Note:  3 in. (75 mm) above any horizontal/in-

clined vent component.

**Note:    See 

Page  10,  Step  1

  for  clearance 

requirements  to  the  nailing  flange  located 

at each side of the unit and any screw heads 

adjacent to it.

Appliance and Vent Clearances

The appliance is approved with zero clearance to 

combustible materials on all sides (as detailed 

in 

Table 8)

, with the following exception: When 

the unit is installed with one side flush with a 

wall, the wall on the other side of the unit must 

not extend beyond the front edge of the unit.  

Refer to 

Figure 4

.

Содержание SSDV-3328

Страница 1: ... Follow your gas suppliers instructions If your gas supplier cannot be reached call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING IFTHEINFORMATIONINTHISMANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLO SIONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE POUR VOTRE SÉCURITÉ Ne pas entreposer ni utiliser...

Страница 2: ...owner s manual installation instructions and war ranty envelope is located in the control compartment 3 One vent restrictor to be applied as shown on Page 13 restrictor is taped to the envelope 4 One hood located behind the top panel 5 Onebagofdecorativevolcanicstonelocated in the control compartment 6 One bag of glowing embers located in the control compartment This appliance is only for use with...

Страница 3: ...olt models Fuel Low High Natural Gas Lo 2 2 WC 55 kPa Hi 3 5 WC 87 kPa Propane Lo 6 3 WC 1 57 kPa Hi 10 0 WC 2 49 kPa Table 4 Test gauge connections are provided on the front of the millivolt gas control valve identi fied IN for the inlet and OUT for the manifold side A 1 8 NPT Test gauge connection is provided at the inlet and outlet side of the electronic gas control valve Burner Orifice Sizes E...

Страница 4: ...ector must comply with NFPA 720 be ANSI UL 2034 listed and be IAS certified A metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height of eight 8 feet above grade and be directly in line with the horizontal termination The sign must read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BE LOW KEEP CLEAR OF ALL OBSTR...

Страница 5: ... temperatures see Figure 4 The location should also be free of electrical plumbing or other heating air conditioning ducting These direct vent appliances are uniquely suited for installations requiring a utility shelf positioned directly above the fireplace Utility shelveslikethesearecommonlyusedforlocat ing television sets and decorative plants Be aware that this is a heat producing appliance Obj...

Страница 6: ...erican National StandardforManufacturedHomes NCSBCS ANSI A225 1 latest edition CAUTIONS Ensure that the cross members are not cut or weakened during installation Thestructuralinteg rity of the manufactured home floor wall andceiling roofmust be maintained Thisappliancemustbegrounded to the chassis of the manufac tured home in accordance with local codes or in the absence of local codes with the Na...

Страница 7: ...ions exceeding 2 1 2 64 mm see Figure 6 All horizontal terminations may be located as close as 6 152mm to any combustible exterior sidewall This distance may be decreased to 2 51mm if the SV4 5HT 2 or SF4 5HT 2 termination is used and the exterior sidewall is non combustible only For additional vent location restrictions refer to Figure 7 on Page 8 Termination Heights For Vents Above Flat Or Slope...

Страница 8: ... h t i w m c 1 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b a t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b a t e l t u o t n e v r o t a l u g e r e c i v r e s o t e c n a r a e l C I m c 1 9 t e e f 3 m c 1 9 t e e f 3 r o g n i d l i u b o t t e l n i y l p p u s r i a l a c i n a h c e m n o n o t...

Страница 9: ...um side wall clearance a combustible wall can project to any length Protected wall shown in white Inches millimeters Figure 10 At 8 1 4 side wall clearance a combustible wall can project 12 Hood Mantel Depth 4 102 2 51 4 102 6 152 8 203 10 254 12 305 6 152 10 254 14 356 12 305 8 203 5 127 8 1 4 209 14 356 12 305 19 483 45 o MINIMUM CLEARANCES Inches millimeters Back 1 2 13 0 0 Spacers Sides 1 2 13...

Страница 10: ...provided and bringinelectricalservicelineforforcedair circulating blower optional equipment b ElectronicAppliances Fieldwireandinstall operating control switch Step 5 Page 25 Install blower kit optional equipment Step 6 Page 26 Make connection to gas sup ply Step 7 Page 27 Checkout appliance operation Step 8 Page 28 Install the logs decorative volcanic stone and glowing embers Step 9 Page 30 Insta...

Страница 11: ...dels only ELECTRICAL INLET 2 3 4 x 2 70 x 51 COVER PLATE with KNOCKOUT Right Side View SSDVR models have only a rear vent SSDVT models have only a top vent 6 13 16 173 2 3 4 70 33 1 8 841 30 1 8 765 27 1 2 699 17 432 19 5 8 498 10 3 4 273 33 1 8 841 Inches millimeters 1 25 1 25 Notes Due to Lennox ongoing commitment to quality all specifications ratings and dimensions are subject to change without...

Страница 12: ...ver use galvanized or plastic pipe Refer to Table 9 for proper sizing of the gas supply line if black iron pipe is being used Gas lines must be routed constructed and made of materials that are in strict accordance with local codes and regulations We recommend that a quali fied individual such as a plumber or gas fitter be hired to correctly size and route the gas supply line to the appliance Inst...

Страница 13: ...he vent pipe is tested to be run inside an enclosing wall such as a chase There is no requirement for inspection openings in the enclosing wall at any of the joints in the vent pipe WARNING Failure to reinstall and securely tighten cover plate screws could result in leakage of flue products into the living space Vent cover plate and vent seal plate must remain securely installed on unused vent col...

Страница 14: ... 5 1 3 5 2 6 2 0 3 0 0 0 3 5 4 3 5 7 8 2 0 0 0 1 0 1 5 7 3 5 2 1 3 1 1 1 0 0 3 5 3 4 5 2 6 3 0 2 1 0 0 3 5 4 5 7 3 0 0 2 0 0 2 5 6 4 5 7 8 3 0 0 0 0 1 1 5 9 4 5 2 1 4 1 0 2 0 0 3 1 5 5 2 4 1 0 0 0 1 2 5 5 5 5 2 6 4 0 1 2 0 0 3 7 5 5 7 4 0 0 1 1 0 2 6 6 5 2 5 0 2 2 0 0 4 5 7 6 5 2 6 5 0 0 3 0 0 3 9 6 5 7 5 0 0 0 2 0 2 2 7 6 1 0 3 0 0 4 5 3 7 5 2 1 6 1 0 0 2 0 3 5 9 7 5 2 6 6 0 1 0 2 0 3 1 8 5 7 6 0...

Страница 15: ...nselectinglengthcombinations Elbowsare available in 90 and 45 configurations Refer to Figure 22 on Page 16 for the SV4 5E45 and SV4 5E90 elbow dimensional specifications Where required a telescopic vent section SV4 5LA may be used to provide the installer withanoptionininstallingintightand confined spaces or where the vent run made up of fixed length pieces develops a joint in a undesirable locati...

Страница 16: ... the center axis of their initial collar section to align with the required direction of the next vent run element Twist elbow sections in a clockwise direction only so as to avoid the possiblity of unlocking anyofthepreviouslyconnectedventsections See Figure 22 K Install the vertical termination The final step involves installation of the SV4 5CGV 1 Vertical Termination Extend the vent sections t...

Страница 17: ...ingSecureFlex useFirestop Spacer SF4 5VF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF uWhen using Secure Flex use Firestop Spacer SF4 5VF vWhen using Secure Flex use Firestop Spacer SF4 5HF Table A H Maximum V Minimum feet meter feet meter 2 0 610 1 0 305 4 1 219 2 0 610 6 1 829 3 0 914 8 2 438 4 1 219 V H 40 feet 12 2 meters Max H 8 feet 2 4 mete...

Страница 18: ...Flex useFirestop SpacerSF4 5HF Figure 29 Rear Vent three elbows Figure 30 Top Vent three elbows VERTICAL VENT FIGURES TABLES CONTINUED Horizontal Outside Wall Termination System Figure 31 and Figures 34 to 40 on Pages 21 to 23 and their associated Horizontal Vent Table illustrate the various horizontal venting configurations that are possible for use with theseappliances SecureVentpipeapplications...

Страница 19: ...nels of the previous section Push the vent component against the previous section until it fully engages then twist the componentclockwiserunningthedimplesdown and along the incline channels until they seat at the end of the channels This seating position is indicated by the alignment of the arrow and dimple as shown in Figure 20 on Page 15 F Install firestop spacer at ceiling WhenusingSecureVent ...

Страница 20: ... 5HT 2 Termination J Assemble vent run to exterior wall If not previously measured locate the center of the vent at the exterior wall Prepare an opening as described in Step B Assemble the vent system topointwheretheterminusofthelastsectionis located relative to the exterior surface to which the termination is to be attached see Figures 32 33 and Table 12 on Page 21 If the terminus of the last sec...

Страница 21: ...ACCEPTABLE AS 1 FOOT OF VERTICAL RISE EXCEPT WHERE AN ELBOW IS THE ONLY VERTICAL COMPONENT IN THE SYSTEM See Figure 35 See Table 12 as an aid in venting component selection for a particular range of exterior wall thicknesses WARNING Under no circumstances may separate sections of concentric flexible vent pipe be joined together HORIZONTAL VENT FIGURES TABLES Figure 36 Top Vent ONE 90 DEGREE ELBOW ...

Страница 22: ...See Table 12 on Page 21 as an aid in venting component selection for a particular range of exterior wall thicknesses HORIZONTAL VENT FIGURES TABLES CONTINUED Table H H H1 Maximum HMaximum V Minimum feet meter feet meter feet meter 5 1 524 2 0 610 1 0 305 10 3 048 4 1 219 2 0 610 15 4 572 6 1 829 3 0 914 20 6 096 8 2 438 4 1 219 V H H1 40feet 12 2m Max H 8 feet 2 438 meters Max H H1 20 feet 6 096 m...

Страница 23: ...t of horizontal run up to a maximum total H H1 H2 horizontal run of 20 feet Figure 40 Top Vent THREE 90 DEGREE ELBOWS Figure 39 Rear Vent THREE 90 DEGREE ELBOWS See Table 12 on Page 21 as an aid in venting component selection for aparticularrangeofexte rior wall thicknesses See Table 12 on Page 21 as an aid in venting component selection for a particular range of exterior wall thicknesses HORIZONT...

Страница 24: ...ovideadditional security to the connection B Install the Outer Flex Pipe 1 Install the large gear clamp loosely around the outer flexible vent pipe push it back out of the way 2 ApplyabeadofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the outer adapter collar to the grooves of the collar which extend approximately 1 inch from the end and to the flat surface approximately 1 3 4 ...

Страница 25: ...trical power must be connectedtoeitherofthesereceptaclesinorder to operate these blowers Install the blower kits according to the installation instructions provided with the kits 3 Wire the control within the millivolt control circuit using the 15 feet of 2 conductor wire supplied with the unit Caution do not connect the optional wall switch to a 120V power supply 4 Alternatively theappliancemaybe...

Страница 26: ...cal codes the National Electrical Code ANSI NFPA 70 latest edition In Canada the current CSA C22 1 Canadian Electrical Code Step 6 Connecting Gas Line Make gas line connections All codes require a shut offvalvemountedinthesupplyline Figure 46 illustrates two methods for connecting the gas supply The flex line method is acceptable in the U S however Canadian requirements vary depending on locality ...

Страница 27: ... Appliance Opera tion With the gas line installed run initial system checkout before closing up the front of the appliance Follow the pilot lighting instructions provided in the Homeowner s Care and Opera tion Instructions For piezo igniter location see Figure 48 millivolt appliances only Note The pull out Lightinginstructionslabel can be found in the control compartment see Figure 47 When first l...

Страница 28: ... edge of the ember bracket 4 Insert the alignment hole of the right twig over the front log s right pin Rotate the right twig until it almost touches the front panel glass Note Propertwigplacementiscriticalinthe gapsbetweentheflamepeaksandshouldbe positioned so that at no time they impinge the flames Glowing Ember Volcanic Stone Placement Remove the replacement rockwool Glowing Embers from the pac...

Страница 29: ...Volcanic Stone Table 13 Bag of Glowing Embers rockwool Separate into Quarter Size separate Pieces WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested for leaks and the initial burner operation has been checked out Figure 53 Glowing Embers WARNING This appliance is not designed to burn wood Any attempt to do so could cause irreparab...

Страница 30: ... The glass door of this appli ance must only be replaced as a complete unit as provided by themanufacturer Donotattempt to replace broken cracked or chipped glass separately WARNING Do not attempt to touch the front enclosure glass with your hands while the fireplace is in use Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning to ensure that the...

Страница 31: ...See Page 6 for Cold Climate Insulation and Page 9 for Clearances Burner Air Shutter Adjustment Procedure CAUTION Theairshutterdoorandnearbyappliancesurfacesare hot Exercise caution to avoid injury while adjusting flame appearance Burner Air Shutter Adjustment Procedure 1 Locate adjustment rod and adjust air shutter to the standard setting as shown in Figure 56 adjustment rod is located in the lowe...

Страница 32: ...7 1 2 effective length 4 77L76 SV4 5E45 45 Degree Elbow 5 77L77 SV4 5E90 90 Degree Elbow 3 4 5 6 7 10 1 8 9 11 Installation Accessories The following flashings come packaged with a storm collar 6 77L78 SV4 5F Flat Roof Flashing 6 77L79 SV4 5FA 1 2 to 7 12 Adjustable Flashing 6 77L80 SV4 5FB 7 2 to 12 12 Adjustable Flashing 7 77L81 SV4 5SC6 Storm Collar 6 per box 8 H2246 SV4 5HF Firestop Spacer Hor...

Страница 33: ...SFMP 12 Mill Pac Black High Temperature Sealant Bulk 12 pack 23 91L66 SF GC4 6 Gear Clamp 4 5 in 114 mm for flex 6 pieces 23 91L67 SF GC7 6 Gear Clamp 7 5 in 190 5 mm for flex 6 pieces 24 99L02 SV4 5HRK14 Horizontal Riser Kit 14 24 99L03 SV4 5HRK36 Horizontal Riser Kit 36 25 H1988 CTSA 33 Chase Top Shroud Kit Arch Top 3 X 3 26 H1985 CTSO 33 Chase Top Shroud Kit Open Top 3 X 3 26 H1987 CTSO 44 Chas...

Страница 34: ...structionssuppliedwiththekit The qualified service agency performing thisinstallationassumesresponsibil ity for this conversion AVERTISSEMENT Cet équipement de conversion sera installé par une agence qualifiée de service conformément aux instruc tionsdufabricantettoutesexigences et codes applicables de l autorisés avoir la juridiction Si l information danscetteinstructionn estpassuivie exactement ...

Страница 35: ...ning it clockwise Replace the plastic protecting cap Pilot for Honeywell Millivolt Gas Valve Loosening of Hex Fitting For Orifice Strip Tab Positioning Figure 62 7 16 in Open End Wrench Hood Hood Alignment Orifice Strip Tab Take care not to contact the orifice strip tab with the hex fitting wrench distortion of the tab may render the pilot inoperative LP propane Gas Posi tion 1 16 inch hole LP and...

Страница 36: ...the kit See Table 14 for orifice sizes required for use with natural gas or propane gas Figure 65 illustrated the orifice Step 6 Electronic Appliances Honeywell Systems See Figure 63 and the instructions provided with the kit Remove the slotted cap screw o ring pressure regulating adjusting screw and spring Retain all parts for possible later use Install new components from the kit Black cap and r...

Отзывы: