Series Premier VS-VH
Page 32
LT135 Dec 2019
E - Optional Shield Equipment
Bottom Shields
Bottom Shields do not need to overlap. Each 5 ft. (1.5 m) section is held with two Support Brackets. Secure each of
the Support Brackets around the Tube with supplied fastener and attach to bottom shield with #8 x 3/8” screws.
Refer to Figure 25 below for reference.
Figure 25: Bottom Shield Installation Detail
Burner Reflectors
Burner Reflectors are used to maintain a continuous Reflector surface along the length of the Heat Exchanger
instead of ending and restarting Reflector runs with End Caps at each Burner location.
Burner Reflectors are installed after the Burner installation, and before/during assembly of the main Reflector run.
All pieces are connected using #8 x 3/8” Screws. The Side pieces and End Sections are installed first to create a
Base to secure the Burner Reflector sections to. Overlap the Burner Reflectors with Standard Reflectors and
secure the Reflectors together with Support Brackets. Refer to the sequence of images in Figure 26 for more detail.
Содержание Premier VS-VH
Страница 8: ...Series Premier VS VH Page 8 LT135 Dec 2019 Figure 2 Non Symmetric System Overview...
Страница 9: ...Series Premier VS VH Page 9 LT135 Dec 2019 Basic Components Figure 3 Common Component Dimensions...
Страница 12: ...Series Premier VS VH Page 12 LT135 Dec 2019 Figure 6 Locations of Burner Labels Stickers...
Страница 27: ...Series Premier VS VH Page 27 LT135 Dec 2019 Figure 17 Air Plate Change Out Procedure...
Страница 33: ...Series Premier VS VH Page 33 LT135 Dec 2019 Figure 26 Burner Reflector Installation Sequence Details...