Figure 11 - Door Installation

DOOR REMOVAL

To remove the door, simply pull the door up from the hinges (see 

Figure 

11)

.  The door adjustment has been set at the factory.  If the fit is still not 

perfect, you can adjust the door using the hinge screws.

Figure 12

DOOR ADJUSTMENT

The door may need to be adjusted to be completely airtight. The gaskets’ 

air-tightness can be adjusted using two adjustment screws located on the 

right side of the fireplace facade (An Allen key #1/8 – not supplied - will 

be necessary for this adjustment).

  WARNING

 

Use only a IHP glass door, specifically designed 

for the fireplace.

 

The fireplace cannot be operated without door.  

Consult your dealer to select the correct replace-

ment door.

 

Important! To assure proper alignment of glass 

door:  Install this fireplace in a square and plumb 

condition, using shims as necessary at sides 

and/or bottom.

Checking Door Seal 

A one-inch strip of paper may be used to perform a test of the integrity 

of the door seal. Close the door on the paper in at least eight points.  It 

is normal to feel only a slight amount of friction. The door gasket does 

not need to be “tight” in all areas, since a small amount of leakage is not 

hazardous or detrimental to the performance of your fireplace.

GLASS CARE

Glass Replacement

The glass used for the fireplace is a high temperature ceramic glass (1,400° 

F / 760° C).  If the glass breaks, it must be replaced with an identical ce-

ramic glass.  Tempered glass or ordinary glass will not withstand the high 

temperatures of the fireplace.  Replacement glass should be purchased 

from a IHP dealer (see “Replacement Parts”, 

Page 28)

.  

DO NOT OPERATE THE UNIT WITH CRACKED OR BROKEN GLASS. 

Glass Cleaning

The fireplace is designed to keep the glass clean under normal operating 

conditions. If the fireplace is operated continuously with the combus-

tion air controls closed, the glass will tend to get dirty unless the fuel, 

firebox and glass are maintained at hot temperatures (see “Refueling For 

Best Performance”).  To clean the glass, there are a number of specially 

designed cleaners.  Your IHP dealer can recommend a suitable cleaner 

which is available in your area.  Regular household glass cleaners will not 

clean creosote.  

Do not use abrasives such as steel pads, steel wool or 

oven cleaner as they will scratch the glass.

 

DO NOT USE CHEMICAL GLASS CLEANERS ON PAINTED SURFACES 

AS IT MAY CAUSE THE PAINT TO PEEL.

CAUTION : DO NOT ALLOW WINDOW CLEANER TO GET IN CONTACT 

WITH DOOR GASKET OR PAINT ON FACADE OR DOOR.  ONCE CLOSED, 

CONTACT OF GLASS CLEANER WITH THE FIREPLACE FACADE CAN 

PROVOKE PAINT PEELING OFF.

Gasket Replacement

Remove the door from the unit (see 

Page 12)

 and lay it on a clean un-

abrasive surface. To replace the gasket, first remove all of the old gasket 

and gasket cement.  Make sure that the surface is totally clean before 

applying new cement (a high temperature silicone caulking rated at 500° 

F [260° C], is suitable) or adhesion problems may result.  Apply gasket 

cement to the gasket channel and install the new gasket.  This replace-

ment part is available from your IHP dealer in the following dimensions:

Gasket

Length*

Dimensions

Part No.

Around Glass

69

(1753)

1 x 3/16

(25 x 4.8)

PR-SR1685H

On Door Frame

73

(1854)

3/4 dia

(19.5)

PR-SR1823O 

Table 1 

 

*NOTE: Inches (millimeters)

Gasket 

Adjustment 

Screw

Hinges

Adjustment

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

12

Содержание WRT3920

Страница 1: ...orrect replacement door The fireplace is equipped with a blower electri cal connection must be made prior to fireplace installation Important To assure proper alignment of glass door Installthisfirepl...

Страница 2: ...use with a gas log set Do not use a fireplace insert or any other product with this fireplace unless it is specified by IHP for use with this ap pliance Failure to follow these instructions will void...

Страница 3: ...nt length to be blown in front ofanopenflamewhenthewindow is opened Keep any combustible furniture materials or decorative pillows at least 48 1219 mm from the front fireplace opening WARNING Never le...

Страница 4: ...sthecatalyticcombustor Openingthe CAT bypass damper control increases the draft allowing the unit to achieve proper operating temperatures during a cold start up It also provides more draft to prevent...

Страница 5: ...d For instance a long chimney will necessitate closing the damper more To obtain the proper combustion closethedampercompletely then open it about 1 4 to 1 2 6 4mm to 13mm Two medium size pieces of wo...

Страница 6: ...It takesabout15 30minuteswiththeCATbypass opened to reach proper light off temperatures for the catalytic combustor Step 5 Set the primary control to the desired burn level The fireplace will automati...

Страница 7: ...oisture content can exceed 80 which must be reduced to less than 20 Wood properly seasoned is then capable of generating the heat the stove was designed to provide Greenwooddoesnotburneasily Attemptin...

Страница 8: ...ombustor Remove dust accumulation after chimney sweep and put the combustor back in place CATALYTIC COMBUSTOR This fireplace is designed with a catalytic com bustor which will reduce pollution emissio...

Страница 9: ...rewsandslidingthehingebracketupordown to create better seal and then retightening Catalyst Bypass linkage replacement see Figure 8B Toolsrequired 2 9 16 wrenches 2square drive bit driver Withcatalystb...

Страница 10: ...ombustorProblem Thermal Cracking ThiscombustordoesNOTexperiencethermalcracking Notap plicable Appliestohoneycombcombustorsonly CombustorProblem CombustorPeeling ThiscombustordoesNOTexperiencecombustor...

Страница 11: ...ashes are cold 24 to 48 hours after the fire is out Do not leave the ashes in the house as they give off carbon monoxide and other toxic gases Figure 10 Figure 9 WARNING DisposalofAshes Ashesshould be...

Страница 12: ...Replacement Parts Page 28 DO NOT OPERATE THE UNIT WITH CRACKED OR BROKEN GLASS Glass Cleaning The fireplace is designed to keep the glass clean under normal operating conditions If the fireplace is op...

Страница 13: ...replace is determined by considering the location of windows doors and the traffic flow in the room where the fireplace is located allowing space in front of the unit for the hearth exten sion and the...

Страница 14: ...p must cover the entire width of the fireplace The combustible floor in front of the fireplace must be covered with at least a 1 2 inch of non combustible material tile marble stone etc See Figure 15...

Страница 15: ...raphs are not to scale consult installation instructions Product designs materials dimensions specifications colorsandpricesaresubjecttochangeordiscontinu ance without notice Allframingdimensionscalcu...

Страница 16: ...replace Side Mantel Rock Board or Other Noncombustible Facing 39 990 mm Drywall 2 x 3 Min 51mm x 76mm Standoff Mantel and Facing Side View Rock Board or Other Noncombustible Facing Drywall Figure 17 F...

Страница 17: ...mbustible Facing Drywall 2 x 3 Min Rock Board or Other Spacer Figure 22 A wall on off switch must be installed to control theblower Anoptionalheatswitchandvariable speed control are available see Page...

Страница 18: ...must be non combustible below this area u NOTES Seal the top and both sides of the roof flashing with waterproof caulk ing The gap between the vent pipe and a vertical firestop shall be sealed with no...

Страница 19: ...ase of the fireplace C The fresh air must come from outside the house The air intake must not draw air from the attic basement or garage D The air intake should be installed where it is not likely to...

Страница 20: ...for every 2 000 feet 600 m above sea level 5 All chimney installations must include at least one support Re ducing the amount of chimney weight on the fireplace will help avoid the noise created when...

Страница 21: ...tions B A Framing lumber of equal size to the joist should be used Figure 35 FEMALE END MALE END BUTTON LOCK ATTACH FOR LOCK Figure 36 INSULATION SHIELD CAT NO SPIS NAIL FIRESTOP CAT NO SPFS Chimney F...

Страница 22: ...ance to combustibles AT THIS POINT TIGHTEN CLAMPS 11 Slide IHP chimney pipe into top of tee Align male and female ends Push down on pipe sec tions until locked As sections are added it will be necessa...

Страница 23: ...all the next SP chimney section through the roof See Figure 41 NOTE If your roof is already shingled be sure to slide the upper edge under the shingles to prevent leakage 3 Install a bead of caulk aro...

Страница 24: ...verse wind conditions etc may create a need for a taller chimney should smoking occur Additional support is required above the roof if the chimney height exceeds four 4 feet Select the proper support...

Страница 25: ...nts as per these installation instructions and instructions provided by the venting Manufacturer Referencetheinstallationinstructionsprovidedbyventingmanufacturer CHIMNEY CHASE AND MULTIPLE TERMINATIO...

Страница 26: ...se the size of the hole until a 30 liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip through the hole a 30 line...

Страница 27: ...No Cast Surround Kit CSK H7303 Cast Surround Decorative Keystone CSK DK H7757 Central Forced Air Kit Accessories Central Forced Air Kit Central forced air kit including blower BISZY flex adaptor BISA...

Страница 28: ...ctory 2 pieces PR SR2829 Secondary air tubes set of three F3540 Fireplace Ashlip F3551 Fireplace Front Bottom F3550 Top Front Insulation Protector F3554 Gasket Catalyst F3552 Catalyst Replacement Cart...

Страница 29: ...and CAN ULC S629 Description Part Cat No Lengths and Misc Chimney Components 8 length 6 Dia 6DTC 08SS 12 length 6 Dia 6DTC 12SS 18 length 6 Dia 6DTC 18SS 24 length 6 Dia 6DTC 24SS 36 length 6 Dia 6DTC...

Страница 30: ...S COMPOSANTES UTILIS ES AVEC LE FOYER DOIVENT TRE HO MOLOGU ES VOIR LA LISTE DANS LE MANUEL D INSTALLATION REMPLACER LA VITRE AVEC UN VERRE C RAMIQUE DE 5mm D PAISSEUR POUR UNE UTILISATION S CURITAIRE...

Страница 31: ...____________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________...

Страница 32: ...ct d damages repairs or inefficiency resulting from faulty installation or application of the Product IHP is not responsible for inadequate system draft caused by air conditioning and heating systems...

Страница 33: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Страница 34: ...8 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing p...

Отзывы: