background image

Figure 1

Thermometer

OPERATING THE FIREPLACE

Fuel - 

USE SOLID NATURAL WOOD FUEL 

ONLY. 

This appliance is designed to burn dry 

seasoned natural wood only (see Page 8 for a 

list of prohibited fuels). Failure to burn proper 

fuels only will void the certification and the 

warranty of the appliance. Hardwoods

 are 

preferred to softwoods since the energy content 

of wood is relative to its density.  Hardwoods 

will result in a longer burning fire and less 

frequent refueling.

A moisture content of 15% to 20% (seasoned) 

is recommended.  Wood that has been cut and 

split and let to dry under a cover for a period 

of one year will usually meet that criteria.  The 

required drying time will vary depending on the 

climate. Wood that is packed tight together will 

take longer to dry. Seasoned wood is darker in 

color than wet wood and will have visible cracks 

in the grain on the ends.  

Excessively wet wood 

will be difficult to burn and will result in lower 

efficiency, increased creosoting and plugging 

of the catalytic combustor.  Excessively dry 

wood will burn well but will also have higher 

emissions and shorter burning time.

DO NOT OVERFIRE THIS HEATER

Attempts to achieve heat output rates that 

exceed heater design specifications can result 

in permanent damage to the heater.

First Fires

The first five or six fires should be small fires 

of short duration (about 30 to 60 minutes). 

 

This will help cure the refractory bricks. 

During 

the first few fires of this appliance there may 

be some odor and smoke due to the curing of 

the paint, dust accumulation and burning off of 

lubricants used in the manufacturing process.   

It may set off a smoke alarm located in the same 

room.  For this reason the room should be well 

ventilated for the first few fires.

Catalytic Combustor

This fireplace is equipped with a catalytic com-

bustor.  Unburned by-products of the wood fire 

are burned as they pass through the combustor 

resulting in less pollution, reduced creosote and 

higher efficiency.  In order to have the catalyst 

working, temperatures of the flue gases entering 

the combustor have to be higher than 500° F 

(260° C).  That is why the unit is equipped with 

a CAT bypass damper that allows the draft air 

to bypass the catalytic combustor.  Opening the 

CAT bypass damper control increases the draft 

allowing the unit to achieve proper operating 

temperatures during a cold start-up.  It also 

provides more draft to prevent smoke spillage 

when the door is opened. 

Catalytic CAT Bypass Gauge

To determine when to close the CAT bypass, 

the unit is equipped with a gauge

 (see Figure 

1)

. Once you can see the gauge needle in the 

catalytic combustor operating range, you may 

push to close the CAT bypass lever, about 15-30 

minutes after initial light-off.

When the catalyst light-off conditions are 

achieved, the combustor will keep on going 

until it runs out of smoke.  Note that the catalyst 

does not need to be glowing to be working, it 

can work very well at temperatures well below 

the 538° C (1000° F) level at which it will begin 

to glow.  The best way to see if the catalyst is 

active is to take a look at what is coming out 

of the chimney.  If the catalytic combustor is 

working you will see some white water vapor 

coming out, compared to a more brown/gray 

smoke when the CAT bypass is opened.  Do 

not burn any chemical chimney cleaner; it can 

make the catalyst inactive.

COMBUSTION CONTROLS

Primary Air Control

There is no flue damper in the fireplace.  As is 

common with air tight stoves, the combustion 

air control sets the flow of air entering the fire-

box.  This allows for a more precise control of 

the fire.  The combustion air control is located 

below the door on the left side.  The main source 

of air (primary air) entering the firebox can 

be diminished by moving the air combustion 

control from left to right. The primary air is 

fully opened when the air control is completely 

moved to the left. 

This manual describes the installation and operation of the IHP model WRT3920WS catalytic 

equipped wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s certified 

to comply with 2020 particulate emission standards using crib wood. Under specific test conditions 

this heater has been shown to deliver heat at rates ranging from 10,900 to 35,600 Btu/hr.

This wood heater has a manufacturer-set minimum low 

burn rate that must not be altered. It is against federal 

regulations to alter this setting or otherwise operate 

this wood heater in a manner inconsistent with the 

operating instructions in this manual.

Detail A

See Detail A

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

4

Содержание WRT3920

Страница 1: ...orrect replacement door The fireplace is equipped with a blower electri cal connection must be made prior to fireplace installation Important To assure proper alignment of glass door Installthisfirepl...

Страница 2: ...use with a gas log set Do not use a fireplace insert or any other product with this fireplace unless it is specified by IHP for use with this ap pliance Failure to follow these instructions will void...

Страница 3: ...nt length to be blown in front ofanopenflamewhenthewindow is opened Keep any combustible furniture materials or decorative pillows at least 48 1219 mm from the front fireplace opening WARNING Never le...

Страница 4: ...sthecatalyticcombustor Openingthe CAT bypass damper control increases the draft allowing the unit to achieve proper operating temperatures during a cold start up It also provides more draft to prevent...

Страница 5: ...d For instance a long chimney will necessitate closing the damper more To obtain the proper combustion closethedampercompletely then open it about 1 4 to 1 2 6 4mm to 13mm Two medium size pieces of wo...

Страница 6: ...It takesabout15 30minuteswiththeCATbypass opened to reach proper light off temperatures for the catalytic combustor Step 5 Set the primary control to the desired burn level The fireplace will automati...

Страница 7: ...oisture content can exceed 80 which must be reduced to less than 20 Wood properly seasoned is then capable of generating the heat the stove was designed to provide Greenwooddoesnotburneasily Attemptin...

Страница 8: ...ombustor Remove dust accumulation after chimney sweep and put the combustor back in place CATALYTIC COMBUSTOR This fireplace is designed with a catalytic com bustor which will reduce pollution emissio...

Страница 9: ...rewsandslidingthehingebracketupordown to create better seal and then retightening Catalyst Bypass linkage replacement see Figure 8B Toolsrequired 2 9 16 wrenches 2square drive bit driver Withcatalystb...

Страница 10: ...ombustorProblem Thermal Cracking ThiscombustordoesNOTexperiencethermalcracking Notap plicable Appliestohoneycombcombustorsonly CombustorProblem CombustorPeeling ThiscombustordoesNOTexperiencecombustor...

Страница 11: ...ashes are cold 24 to 48 hours after the fire is out Do not leave the ashes in the house as they give off carbon monoxide and other toxic gases Figure 10 Figure 9 WARNING DisposalofAshes Ashesshould be...

Страница 12: ...Replacement Parts Page 28 DO NOT OPERATE THE UNIT WITH CRACKED OR BROKEN GLASS Glass Cleaning The fireplace is designed to keep the glass clean under normal operating conditions If the fireplace is op...

Страница 13: ...replace is determined by considering the location of windows doors and the traffic flow in the room where the fireplace is located allowing space in front of the unit for the hearth exten sion and the...

Страница 14: ...p must cover the entire width of the fireplace The combustible floor in front of the fireplace must be covered with at least a 1 2 inch of non combustible material tile marble stone etc See Figure 15...

Страница 15: ...raphs are not to scale consult installation instructions Product designs materials dimensions specifications colorsandpricesaresubjecttochangeordiscontinu ance without notice Allframingdimensionscalcu...

Страница 16: ...replace Side Mantel Rock Board or Other Noncombustible Facing 39 990 mm Drywall 2 x 3 Min 51mm x 76mm Standoff Mantel and Facing Side View Rock Board or Other Noncombustible Facing Drywall Figure 17 F...

Страница 17: ...mbustible Facing Drywall 2 x 3 Min Rock Board or Other Spacer Figure 22 A wall on off switch must be installed to control theblower Anoptionalheatswitchandvariable speed control are available see Page...

Страница 18: ...must be non combustible below this area u NOTES Seal the top and both sides of the roof flashing with waterproof caulk ing The gap between the vent pipe and a vertical firestop shall be sealed with no...

Страница 19: ...ase of the fireplace C The fresh air must come from outside the house The air intake must not draw air from the attic basement or garage D The air intake should be installed where it is not likely to...

Страница 20: ...for every 2 000 feet 600 m above sea level 5 All chimney installations must include at least one support Re ducing the amount of chimney weight on the fireplace will help avoid the noise created when...

Страница 21: ...tions B A Framing lumber of equal size to the joist should be used Figure 35 FEMALE END MALE END BUTTON LOCK ATTACH FOR LOCK Figure 36 INSULATION SHIELD CAT NO SPIS NAIL FIRESTOP CAT NO SPFS Chimney F...

Страница 22: ...ance to combustibles AT THIS POINT TIGHTEN CLAMPS 11 Slide IHP chimney pipe into top of tee Align male and female ends Push down on pipe sec tions until locked As sections are added it will be necessa...

Страница 23: ...all the next SP chimney section through the roof See Figure 41 NOTE If your roof is already shingled be sure to slide the upper edge under the shingles to prevent leakage 3 Install a bead of caulk aro...

Страница 24: ...verse wind conditions etc may create a need for a taller chimney should smoking occur Additional support is required above the roof if the chimney height exceeds four 4 feet Select the proper support...

Страница 25: ...nts as per these installation instructions and instructions provided by the venting Manufacturer Referencetheinstallationinstructionsprovidedbyventingmanufacturer CHIMNEY CHASE AND MULTIPLE TERMINATIO...

Страница 26: ...se the size of the hole until a 30 liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip through the hole a 30 line...

Страница 27: ...No Cast Surround Kit CSK H7303 Cast Surround Decorative Keystone CSK DK H7757 Central Forced Air Kit Accessories Central Forced Air Kit Central forced air kit including blower BISZY flex adaptor BISA...

Страница 28: ...ctory 2 pieces PR SR2829 Secondary air tubes set of three F3540 Fireplace Ashlip F3551 Fireplace Front Bottom F3550 Top Front Insulation Protector F3554 Gasket Catalyst F3552 Catalyst Replacement Cart...

Страница 29: ...and CAN ULC S629 Description Part Cat No Lengths and Misc Chimney Components 8 length 6 Dia 6DTC 08SS 12 length 6 Dia 6DTC 12SS 18 length 6 Dia 6DTC 18SS 24 length 6 Dia 6DTC 24SS 36 length 6 Dia 6DTC...

Страница 30: ...S COMPOSANTES UTILIS ES AVEC LE FOYER DOIVENT TRE HO MOLOGU ES VOIR LA LISTE DANS LE MANUEL D INSTALLATION REMPLACER LA VITRE AVEC UN VERRE C RAMIQUE DE 5mm D PAISSEUR POUR UNE UTILISATION S CURITAIRE...

Страница 31: ...____________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________...

Страница 32: ...ct d damages repairs or inefficiency resulting from faulty installation or application of the Product IHP is not responsible for inadequate system draft caused by air conditioning and heating systems...

Страница 33: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Страница 34: ...8 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing p...

Отзывы: