background image

SAFETY / LISTING LABEL WRT3920WS

Model / Modèle:  W

RT3920WS

CLEARANCES TO COMBUSTIBLES:

SIDE 

W

ALL (FROM DOOR EDGE)

 

24 in. (610 mm)

MANTEL (ABOVE FIREPLACE’S BASE)

 39 in. (990 mm)

BACK 

W

ALL (FROM S

PACERS)

 

0 in. 

 (0 mm)

ABOVE THE FIREPLACE (FROM 

      THE BASE OF THE FIREPLACE)

 

6 ft. 8 in. (2032 mm)

CHIMNEY 

2 in. 

 (51 mm)

DÉGAGEMENTS AUX COMBUSTIBLES:

MUR L

ATÉRAL (DE 

L’OUVE

RTURE DE LA PO

RTE)

 

24 po.

 (610 mm)

LINTEAU (AU-DESSUS DE LA BASE DU FOYER)

 

39 po.

 (990 mm)

MUR ARRIÈRE ET CÔTÉ DU FOYER (DES ES

PACEURS)

 0 po. 

 (0 mm)

AU-DESSUS DU FOYER (À 

PA

RTIR DE LA BASE 

      DU FOYER) 

6 pi. 8 po. (2032 mm)

CHEMINÉE 

2 po. 

 (51 mm)

Conforms to / Conforme au :  UL STD 127

Certified to / Certifié au :   ULC STD S610

LISTED 

FACTO

RY BUI

LT FIREPLACE

FOYER PRÉ

FABRIQUE HOMOLOGUÉ

Manufactured by / Fabriqué par: INNO

VA

TIVE HEA

RTH PRODUCTS

1502 14th St. NW

Auburn, 

W

A  98001 USA

P/N 900842-01, RE

V. 0, 02/2018

• 

USE WOOD FUEL ON

LY

• 

NON

 COMBUSTIBLE

 HEA

RTH

 EXTENSION

 MUST

 BE 

INS

TA

LL

ED

 AT

 FRO

NT

 O

F U

NI

T E

XT

END

ING

 18

 in.

 (45

mm

) A

FRO

NT

 AN

36

 in

. (

91

mm

) W

ID

MI

NIMUM.

• 

TH

IS

 F

IRE

PLAC

HAS

 NOT

 B

EE

N

 TE

ST

ED

 W

IT

UNVENTED

 GAS

 LOG

 SE

T.

 TO

 REDUCE

 RISK

 OF

 FIRE 

OR

 INJU

RY

 DO

 NOT

 INS

TALL

 AN

 UNVENTED

 GAS

 LOG 

SET INTO THE FIREPLACE.

• 

ELECTRICAL R

ATING:  120 

V, 60 Hz

• 

CHIMNEY

 TYPE:

 USE

 ON

LY

 WITH

 LISTED

 6

 in.

 DIAM

-

ETER

 CHIMNE

Y,

 CE

RTIFIED

 MODEL

 ASHT+,

 S-2100+, 

, , AC OR 7 in. ASH

T, HT6103.

• 

CAN

 BE

 CONNECTED

 TO

 A

 MASON

RY

 CHIMNEY

 AS 

DESCRIBED IN THE INS

TALL

ATION INSTRUCTIONS.

• 

COMPONENTS

 USED

 WITH

 THE

 FIREPLACE

 MUST

 BE 

LISTED.

  SEE

 LIST

 IN

 THE

 INS

TALL

ATION

 INSTRUC

-

TIONS.

• 

REPL

ACE

 G

LA

SS

 W

IT

CE

RAM

IC

 G

LASS

 5

 m

m

 T

HIC

K.

• 

FOR

 SAFE

 OPER

ATION

 INS

TALL

 IN

 ACCORDANCE 

WITH THE MANU

FACTURER’S INSTRUCTIONS.

• 

CAUTION:

 COMBUSTION

 AIR

 OPENING

 MUST

 NOT

 BE 

OBSTRUCTED.

• 

DO NOT OVERFIRE THE FIREPLACE.

• 

OPER

ATE

 THE

 FIREPLACE

 WITH

 DOOR

 FUL

LY

 OPEN 

OR FUL

LY CLOSED ON

LY

.

• 

DO

 NOT

 USE

 A

 FIREPLACE

 IN

SE

RT

 OR

 OTHER

 PRODUCT

NOT

 S

PE

CI

FIED

 FOR

 USE

 W

ITH 

THIS

 PRODUC

T

• 

POUR USAGE 

AVEC LE BOIS SEULEMENT

• 

UN

 T

ABLIER

 NON

 COMBUSTIBLE

 DOIT

 ÊTRE

 INS

TALLÉ

 À

 L’

AV

ANT 

DU

 FOYER

 . 

DIMENSION

 MINIMALE

 DE

 18

 po.

 (457

 mm)

 P

AR

 36 

po. (914 mm) DE LARGE.

• 

CE

 FOYER

 N’EST

 P

AS

 HOMOLOGUÉ

 POUR

 ÊTRE

 UTILISÉ

 A

VEC

 UN 

ENSEMBLE

 DE

 BÛCHES

 À

 GAZ

 SANS

 CONDUIT

 D’É

VACU

ATION. 

AFIN

 DE

 RÉDUIR

LES

 R

ISQ

U

ES

 D

’IN

CENDI

OU

 DE

 B

LE

S-

SURES,

 N’INS

TALLEZ

 P

AS

 DE

 BÛCHES

 À

 GAZ

 SANS

 CONDUIT 

D’É

VACU

ATION À 

L’INTÉRIEUR DE CE FOYER.

• 

ALIMEN

TA

TION ÉLECTRIQUE: 120

V, 60 Hz

• 

UTILISER

 SEULEMENT

 A

VEC

 UNE

 CHEMINÉE

 6

 po.

 (150

 mm)

 DE 

DIAMÈTRE,

 MODÈLE

 ASHT+,

 S2100+,

 ,

 

 OU

 AC 

HOMOLOGUÉE OU 7 po. (175mm) ASH

T, HT6103.

• 

PEUT

 ÊTRE

 RACCORDÉ

 SUR

 UNE

 CHEMINÉE

 DE

 MAÇONNERIE 

TEL QUE DÉCRIT DANS LE MANUEL D’INS

TALL

ATION.

• 

LE

CO

M

POS

ANT

ES

 U

TI

LI

SÉES

 A

VEC

 LE

 FO

YER

 DO

IV

ENT

 ÊTR

E H

O-

MOLOGUÉES.

 VOIR

 LA

 LISTE

 DANS

 LE

 MANUEL

 D’INS

TALL

ATION.

• 

REMPLACER

 LA

 VITRE

 A

VEC

 UN

 VERRE

 CÉRAMIQUE

 DE

 5mm 

D’É

PAISSEUR.

• 

POUR

 UNE

 UTILIS

ATION

 SÉCURI

TAIRE,

 INS

TALLER

 CONFORMÉ

-

MENT AUX DIRECTIVES DU 

FABRICAN

T.

• 

AT

TE

NT

IO

: N

E P

AS

 O

BST

RU

ER

 LES

 A

RR

IVÉ

ES

 D

’AI

CO

M

BU

RAN

T.

• 

NE 

PAS 

FAIRE SURCHAUFFER LE FOYER.

• 

LA

 PO

RTE

 DU

 FOYER

 DOIT

 DEMEURER

 TO

TALEMENT

 OUVE

RTE 

OU TO

TALEMENT FERMÉE LORSQUE LE FOYER FONCTIONNE.

• 

N

PAS

 U

TIL

IS

ER

 D

POÊLE

 E

NCA

ST

R

AB

LE

 O

U

 D

’A

UTRE

PRODUITS

 NON

 SPÉCIFIÉS

 COMME

 É

TANT

 UTILISABLES

 A

VEC 

CE PRODUI

T.

• 

CON

TACT

 YOUR

 LOCAL

 BUILDING

 OR

 FIRE

 OFFICIALS

 ABOUT

 RESTRICTIONS

 AND

 INS

TALL

ATION

 INSPECTIONS

 IN

 YOUR 

AREA.

• 

CON

TACTEZ LES RESPONSABLES DE VOTRE REGION A PROPOS DES RESTRICTIONS ET INSPECTIONS D’INS

TALL

ATION.

• 

SEE IHP INS

TALL

ATION AND OPER

ATING INSTRUCTIONS FOR THIS MODEL.

• 

INS

TALL AND USE ON

LY IN ACCORDANCE WITH THE MANU

FACTURER’S INSTRUCTIONS AND LOCAL BUILDING CODES.

• 

SPECIAL

 METHODS

 ARE

 REQUIRED

 WHEN

 P

ASSING

 THROUGH

 A

 W

ALL

 OR

 CEILING.

 SEE

 INSTRUCTIONS

 AND

 BUILDING 

CODES.

• 

PREVENT CREOSOTE FIRE: INSPECT CHIMNEY CONNECTOR AND CHIMNEY FLUE MONTH

LY AND CLEAN IF NECESSA

RY

• 

 DO NOT OVERFIRE. IF DOME OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING.

• 

KEEP FURNISHINGS AND OTHER COMBUSTIBLE M

ATERIALS A CONSIDERABLE DIS

TANCE 

AW

AY FROM APPLIANCE.

• 

MAINTENIR LES MEUBLES ET AUTRES OBJETS À UNE DIS

TANCE SÉCURI

TAIRE DU FOYER.

• 

THIS

 WOOD

 HE

ATER

 NEEDS

 PERIODIC

 INSPECTION

 AND

 RE

PAIR

 FOR

 PROPER

 OPER

ATION.

 CONSU

LT

 THE

 OWNER’S 

MANUAL

 FOR

 FU

RTHER

 INFORM

ATION.

 IT

 IS

 AGAINST

 FEDERAL

 REGUL

ATIONS

 TO

 OPER

ATE

 THIS

 WOOD

 HE

ATER

 IN

 A 

MANNER INCONSISTENT WITH THE OPER

ATING INSTRUCTIONS IN THE OWNER’S MANUAL.

• 

CET

 AP

PAREIL

 DE

 CHAUF

FAGE

 AU

 BOIS

 DOIT

 ÊTRE

 INSPECTE

 ET

 ENTRETENU

 PÉRIODIQUEMENT

 POUR

 FONCTIONNER 

CORRECTEMEN

T.

 VOIR

 LE

 MANUEL

 DU

 PROPRIÉ

TAIRE

 POUR

 PLUS

 D’INFORM

ATION.

 L’UTILIS

ATION

 DE

 CET

 AP

PAREIL

 DE 

CHAUF

FAGE

 AU

 BOIS

 DE

 MANIÈRE

 INCOM

PA

TIBLE

 A

VEC

 LES

 INSTRUCTIONS

 DU

 MANUEL

 DU

 PROPRIÉ

TAIRE

 CONSTITUE 

UNE INFRACTION AUX RÉGUL

ATIONS FÉDÉRALES.

DA

TE OF MFG. 

1     2     3     4     5     6     7     8     9    10    11    12

2019-20-21-22-23-24-25

INS

TALL WITH MINIMUM CLEARANCES TO 

W

ALL 

AS SHOWN IN INCHES.

SIDE

W

ALL - BACK

W

ALL

INS

TALL

ATION

0”

0”

FIREPLACE

FRONT

CORNER INS

TALL

ATION

0”

0”

FIREPLACE

FRONT

FLOOR PROTECTOR MINIMUM DIS

TANCE 

FROM OPENING IN INCHES

HEA

RTH EXTENSION M

ATERIAL :

-   

 3/8 “ THICKNESS NON COMBUSTIBLE 

M

ATERIAL

-   

 OR EQUI

VALENT

FIREPLACE

FRONT

18”

36”

U.S. ENVIRONMEN

TA

L PROTECTION

 AGENCY

Certified to comply with 2020 particulate emission standards 

using crib wood.

C

US

Report No. / Rapport nº

14-181

Serial No. Numéro de série

Certification test emission value 1.8 g/hr per 2020 standard Valeur d’émission du test d’homologation 1,8 g/h selon la norme 2020

30

Содержание WRT3920

Страница 1: ...orrect replacement door The fireplace is equipped with a blower electri cal connection must be made prior to fireplace installation Important To assure proper alignment of glass door Installthisfirepl...

Страница 2: ...use with a gas log set Do not use a fireplace insert or any other product with this fireplace unless it is specified by IHP for use with this ap pliance Failure to follow these instructions will void...

Страница 3: ...nt length to be blown in front ofanopenflamewhenthewindow is opened Keep any combustible furniture materials or decorative pillows at least 48 1219 mm from the front fireplace opening WARNING Never le...

Страница 4: ...sthecatalyticcombustor Openingthe CAT bypass damper control increases the draft allowing the unit to achieve proper operating temperatures during a cold start up It also provides more draft to prevent...

Страница 5: ...d For instance a long chimney will necessitate closing the damper more To obtain the proper combustion closethedampercompletely then open it about 1 4 to 1 2 6 4mm to 13mm Two medium size pieces of wo...

Страница 6: ...It takesabout15 30minuteswiththeCATbypass opened to reach proper light off temperatures for the catalytic combustor Step 5 Set the primary control to the desired burn level The fireplace will automati...

Страница 7: ...oisture content can exceed 80 which must be reduced to less than 20 Wood properly seasoned is then capable of generating the heat the stove was designed to provide Greenwooddoesnotburneasily Attemptin...

Страница 8: ...ombustor Remove dust accumulation after chimney sweep and put the combustor back in place CATALYTIC COMBUSTOR This fireplace is designed with a catalytic com bustor which will reduce pollution emissio...

Страница 9: ...rewsandslidingthehingebracketupordown to create better seal and then retightening Catalyst Bypass linkage replacement see Figure 8B Toolsrequired 2 9 16 wrenches 2square drive bit driver Withcatalystb...

Страница 10: ...ombustorProblem Thermal Cracking ThiscombustordoesNOTexperiencethermalcracking Notap plicable Appliestohoneycombcombustorsonly CombustorProblem CombustorPeeling ThiscombustordoesNOTexperiencecombustor...

Страница 11: ...ashes are cold 24 to 48 hours after the fire is out Do not leave the ashes in the house as they give off carbon monoxide and other toxic gases Figure 10 Figure 9 WARNING DisposalofAshes Ashesshould be...

Страница 12: ...Replacement Parts Page 28 DO NOT OPERATE THE UNIT WITH CRACKED OR BROKEN GLASS Glass Cleaning The fireplace is designed to keep the glass clean under normal operating conditions If the fireplace is op...

Страница 13: ...replace is determined by considering the location of windows doors and the traffic flow in the room where the fireplace is located allowing space in front of the unit for the hearth exten sion and the...

Страница 14: ...p must cover the entire width of the fireplace The combustible floor in front of the fireplace must be covered with at least a 1 2 inch of non combustible material tile marble stone etc See Figure 15...

Страница 15: ...raphs are not to scale consult installation instructions Product designs materials dimensions specifications colorsandpricesaresubjecttochangeordiscontinu ance without notice Allframingdimensionscalcu...

Страница 16: ...replace Side Mantel Rock Board or Other Noncombustible Facing 39 990 mm Drywall 2 x 3 Min 51mm x 76mm Standoff Mantel and Facing Side View Rock Board or Other Noncombustible Facing Drywall Figure 17 F...

Страница 17: ...mbustible Facing Drywall 2 x 3 Min Rock Board or Other Spacer Figure 22 A wall on off switch must be installed to control theblower Anoptionalheatswitchandvariable speed control are available see Page...

Страница 18: ...must be non combustible below this area u NOTES Seal the top and both sides of the roof flashing with waterproof caulk ing The gap between the vent pipe and a vertical firestop shall be sealed with no...

Страница 19: ...ase of the fireplace C The fresh air must come from outside the house The air intake must not draw air from the attic basement or garage D The air intake should be installed where it is not likely to...

Страница 20: ...for every 2 000 feet 600 m above sea level 5 All chimney installations must include at least one support Re ducing the amount of chimney weight on the fireplace will help avoid the noise created when...

Страница 21: ...tions B A Framing lumber of equal size to the joist should be used Figure 35 FEMALE END MALE END BUTTON LOCK ATTACH FOR LOCK Figure 36 INSULATION SHIELD CAT NO SPIS NAIL FIRESTOP CAT NO SPFS Chimney F...

Страница 22: ...ance to combustibles AT THIS POINT TIGHTEN CLAMPS 11 Slide IHP chimney pipe into top of tee Align male and female ends Push down on pipe sec tions until locked As sections are added it will be necessa...

Страница 23: ...all the next SP chimney section through the roof See Figure 41 NOTE If your roof is already shingled be sure to slide the upper edge under the shingles to prevent leakage 3 Install a bead of caulk aro...

Страница 24: ...verse wind conditions etc may create a need for a taller chimney should smoking occur Additional support is required above the roof if the chimney height exceeds four 4 feet Select the proper support...

Страница 25: ...nts as per these installation instructions and instructions provided by the venting Manufacturer Referencetheinstallationinstructionsprovidedbyventingmanufacturer CHIMNEY CHASE AND MULTIPLE TERMINATIO...

Страница 26: ...se the size of the hole until a 30 liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip through the hole a 30 line...

Страница 27: ...No Cast Surround Kit CSK H7303 Cast Surround Decorative Keystone CSK DK H7757 Central Forced Air Kit Accessories Central Forced Air Kit Central forced air kit including blower BISZY flex adaptor BISA...

Страница 28: ...ctory 2 pieces PR SR2829 Secondary air tubes set of three F3540 Fireplace Ashlip F3551 Fireplace Front Bottom F3550 Top Front Insulation Protector F3554 Gasket Catalyst F3552 Catalyst Replacement Cart...

Страница 29: ...and CAN ULC S629 Description Part Cat No Lengths and Misc Chimney Components 8 length 6 Dia 6DTC 08SS 12 length 6 Dia 6DTC 12SS 18 length 6 Dia 6DTC 18SS 24 length 6 Dia 6DTC 24SS 36 length 6 Dia 6DTC...

Страница 30: ...S COMPOSANTES UTILIS ES AVEC LE FOYER DOIVENT TRE HO MOLOGU ES VOIR LA LISTE DANS LE MANUEL D INSTALLATION REMPLACER LA VITRE AVEC UN VERRE C RAMIQUE DE 5mm D PAISSEUR POUR UNE UTILISATION S CURITAIRE...

Страница 31: ...____________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________...

Страница 32: ...ct d damages repairs or inefficiency resulting from faulty installation or application of the Product IHP is not responsible for inadequate system draft caused by air conditioning and heating systems...

Страница 33: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Страница 34: ...8 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing p...

Отзывы: