Fireplace Framing

Header

B

A

*    Total depth is 22-1/2 inches (572mm) including the 

back standoff minus 1/2 inch (13mm) for drywall 

to be flush with the facing.

6’8’’

(2M)

Min.

B

G

2 x 3 

Mi

n.

Rough Framing Face

(dimension includes finish 

material inside framing, if any)

Figure 16  - Framing Dimensions

Combustible materials can NOT 

be used in the space directly 

above the fireplace.  Do not fill 

the space above the fireplace 

with any material (Except the 

wood framing)

Combustion Air Kit

OUTSIDE CHASE

G

C

A

Back Wall of Chase/Enclosure

Including Finishing Materials, if any

Rough Framing Face (Unfinished Shown)

* Zero Clearance 

   From Back 

   Spacer to Wall 

1/2” Plywood

WARNING: IF YOU ARE 

INSTALLING THE CAST 

FACADE PLEASE REFER TO 

THE INSTALLATION SHEET 

PROVIDED WITH THE CAST 

FACADE TO PLAN YOUR 

INSTALLATION.

NOTES

Diagrams, illustrations and photographs are not 

to scale - consult installation instructions. Product 

designs, materials, dimensions, specifications, 

colors and prices are subject to change or discontinu-

ance without notice.
All framing dimensions calculated for 1/2" dry wall at 

the fireplace face.  If sheathing the chase or finishing 

with other thickness materials, calculations will  

need to be made.
* The fireplace must not be in contact with any insula-

tion or loose filling material. Cover the insulation 

with drywall panels around the fireplace.

K (allow space when framing)

K

10-3/4”

(273 mm)

22-3/8”

(568 mm)

31-3/8” (797 mm)

36” (915 mm)

21-5/8” (550 mm)

22-3/8” (569 mm)

25-1/8” (638 mm)

37-5/8”

(956mm)

32-1/2”

(826mm)

22-3/8”

(569 mm)

6-1/8”

(156 mm)

13-1/4”

(337mm)

20” (508 mm)

26-7/8” (683 mm)
35-1/8” (892 mm)

36” (915 mm)

Top View

Front View

Right Side View

Corner Installation

22-1/8”

F

19-5/8”

J

E

D

FRAMING DIMENSIONS

A

36”

915 mm

B

37-3/4”

959 mm

C

31-3/8”

797 mm

D

14-7/8”

378 mm

E

74-3/8”

1889 mm

F

37-1/4”

946 mm

G

*22”

559 mm

J

52-5/8”

1337 mm

K

8”

203 mm

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

15

Содержание WRT3920

Страница 1: ...orrect replacement door The fireplace is equipped with a blower electri cal connection must be made prior to fireplace installation Important To assure proper alignment of glass door Installthisfirepl...

Страница 2: ...use with a gas log set Do not use a fireplace insert or any other product with this fireplace unless it is specified by IHP for use with this ap pliance Failure to follow these instructions will void...

Страница 3: ...nt length to be blown in front ofanopenflamewhenthewindow is opened Keep any combustible furniture materials or decorative pillows at least 48 1219 mm from the front fireplace opening WARNING Never le...

Страница 4: ...sthecatalyticcombustor Openingthe CAT bypass damper control increases the draft allowing the unit to achieve proper operating temperatures during a cold start up It also provides more draft to prevent...

Страница 5: ...d For instance a long chimney will necessitate closing the damper more To obtain the proper combustion closethedampercompletely then open it about 1 4 to 1 2 6 4mm to 13mm Two medium size pieces of wo...

Страница 6: ...It takesabout15 30minuteswiththeCATbypass opened to reach proper light off temperatures for the catalytic combustor Step 5 Set the primary control to the desired burn level The fireplace will automati...

Страница 7: ...oisture content can exceed 80 which must be reduced to less than 20 Wood properly seasoned is then capable of generating the heat the stove was designed to provide Greenwooddoesnotburneasily Attemptin...

Страница 8: ...ombustor Remove dust accumulation after chimney sweep and put the combustor back in place CATALYTIC COMBUSTOR This fireplace is designed with a catalytic com bustor which will reduce pollution emissio...

Страница 9: ...rewsandslidingthehingebracketupordown to create better seal and then retightening Catalyst Bypass linkage replacement see Figure 8B Toolsrequired 2 9 16 wrenches 2square drive bit driver Withcatalystb...

Страница 10: ...ombustorProblem Thermal Cracking ThiscombustordoesNOTexperiencethermalcracking Notap plicable Appliestohoneycombcombustorsonly CombustorProblem CombustorPeeling ThiscombustordoesNOTexperiencecombustor...

Страница 11: ...ashes are cold 24 to 48 hours after the fire is out Do not leave the ashes in the house as they give off carbon monoxide and other toxic gases Figure 10 Figure 9 WARNING DisposalofAshes Ashesshould be...

Страница 12: ...Replacement Parts Page 28 DO NOT OPERATE THE UNIT WITH CRACKED OR BROKEN GLASS Glass Cleaning The fireplace is designed to keep the glass clean under normal operating conditions If the fireplace is op...

Страница 13: ...replace is determined by considering the location of windows doors and the traffic flow in the room where the fireplace is located allowing space in front of the unit for the hearth exten sion and the...

Страница 14: ...p must cover the entire width of the fireplace The combustible floor in front of the fireplace must be covered with at least a 1 2 inch of non combustible material tile marble stone etc See Figure 15...

Страница 15: ...raphs are not to scale consult installation instructions Product designs materials dimensions specifications colorsandpricesaresubjecttochangeordiscontinu ance without notice Allframingdimensionscalcu...

Страница 16: ...replace Side Mantel Rock Board or Other Noncombustible Facing 39 990 mm Drywall 2 x 3 Min 51mm x 76mm Standoff Mantel and Facing Side View Rock Board or Other Noncombustible Facing Drywall Figure 17 F...

Страница 17: ...mbustible Facing Drywall 2 x 3 Min Rock Board or Other Spacer Figure 22 A wall on off switch must be installed to control theblower Anoptionalheatswitchandvariable speed control are available see Page...

Страница 18: ...must be non combustible below this area u NOTES Seal the top and both sides of the roof flashing with waterproof caulk ing The gap between the vent pipe and a vertical firestop shall be sealed with no...

Страница 19: ...ase of the fireplace C The fresh air must come from outside the house The air intake must not draw air from the attic basement or garage D The air intake should be installed where it is not likely to...

Страница 20: ...for every 2 000 feet 600 m above sea level 5 All chimney installations must include at least one support Re ducing the amount of chimney weight on the fireplace will help avoid the noise created when...

Страница 21: ...tions B A Framing lumber of equal size to the joist should be used Figure 35 FEMALE END MALE END BUTTON LOCK ATTACH FOR LOCK Figure 36 INSULATION SHIELD CAT NO SPIS NAIL FIRESTOP CAT NO SPFS Chimney F...

Страница 22: ...ance to combustibles AT THIS POINT TIGHTEN CLAMPS 11 Slide IHP chimney pipe into top of tee Align male and female ends Push down on pipe sec tions until locked As sections are added it will be necessa...

Страница 23: ...all the next SP chimney section through the roof See Figure 41 NOTE If your roof is already shingled be sure to slide the upper edge under the shingles to prevent leakage 3 Install a bead of caulk aro...

Страница 24: ...verse wind conditions etc may create a need for a taller chimney should smoking occur Additional support is required above the roof if the chimney height exceeds four 4 feet Select the proper support...

Страница 25: ...nts as per these installation instructions and instructions provided by the venting Manufacturer Referencetheinstallationinstructionsprovidedbyventingmanufacturer CHIMNEY CHASE AND MULTIPLE TERMINATIO...

Страница 26: ...se the size of the hole until a 30 liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip through the hole a 30 line...

Страница 27: ...No Cast Surround Kit CSK H7303 Cast Surround Decorative Keystone CSK DK H7757 Central Forced Air Kit Accessories Central Forced Air Kit Central forced air kit including blower BISZY flex adaptor BISA...

Страница 28: ...ctory 2 pieces PR SR2829 Secondary air tubes set of three F3540 Fireplace Ashlip F3551 Fireplace Front Bottom F3550 Top Front Insulation Protector F3554 Gasket Catalyst F3552 Catalyst Replacement Cart...

Страница 29: ...and CAN ULC S629 Description Part Cat No Lengths and Misc Chimney Components 8 length 6 Dia 6DTC 08SS 12 length 6 Dia 6DTC 12SS 18 length 6 Dia 6DTC 18SS 24 length 6 Dia 6DTC 24SS 36 length 6 Dia 6DTC...

Страница 30: ...S COMPOSANTES UTILIS ES AVEC LE FOYER DOIVENT TRE HO MOLOGU ES VOIR LA LISTE DANS LE MANUEL D INSTALLATION REMPLACER LA VITRE AVEC UN VERRE C RAMIQUE DE 5mm D PAISSEUR POUR UNE UTILISATION S CURITAIRE...

Страница 31: ...____________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________...

Страница 32: ...ct d damages repairs or inefficiency resulting from faulty installation or application of the Product IHP is not responsible for inadequate system draft caused by air conditioning and heating systems...

Страница 33: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Страница 34: ...8 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing p...

Отзывы: