SAFETY 

 Continued

 WARNING: CONTINUED OVERFIRING CAN PER-

MANENTLY DAMAGE YOUR FIREPLACE SYSTEM. 

SOME EXAMPLES OF CONDITIONS THAT COULD 

CAUSE OVERFIRING ARE:

• BURNING QUANTITIES OF SCRAP LUMBER, PINE 

BRANCHES, PAPER OR CARDBOARD BOXES 

WHICH EXCEED THE VOLUME OF THE NORMAL 

LOG FIRE.

• BURNING TRASH, CHEMICALS OR CHEMICALLY 

TREATED COMBUSTIBLES.

Disposal of Ashes 
Ashes should be placed in a metal container with a 

tight-fitting lid. The closed container of ashes should 

be placed on a noncombustible floor or on the ground, 

well away from all combustible materials, pending 

final disposal. If the ashes are disposed of by burial 

in soil or otherwise locally dispersed, they should be 

retained in the closed container until all cinders have 

thoroughly cooled.

WHEN USING THE DECORATIVE APPLIANCE, THE 

FIREPLACE DAMPER MUST BE SET IN THE FULLY 

OPEN POSITION.

Never use gasoline, gasoline-type lantern fuel, kero-

sene, charcoal lighter fluid, or similar liquids to start 

or ’freshen up’ a fire in this fireplace. Keep all such 

liquids well away from the fireplace while it is in use.

Use SOLID WOOD only for fuel. It is best to use dry 

and well seasoned hardwood. Softwoods tend to burn 

very quickly. DO NOT use treated wood, charcoal, coal, 

trash, driftwood or woods that have been dipped in tar, 

pitch, pine tar, creosote, etc. Wood products made 

with synthetic binders, such as plywood, produce ab-

normally high temperatures and sputtering, smoking 

fires.  When burning artificial logs, please read and 

follow the instructions provided by the manufacturer.
Never burn treated construction lumber or scraps. 

These woods burn excessively hot and may contain 

chemicals used to treat insects and fungus. When 

burned, these chemicals can pose a significant hazard.

IMPORTANT: See appendix A, page 21 for additional 

information regarding draft requirements, smoking 

causes and troubleshooting.

 WARNING: BURNING IMPROPER FUEL (I.E. 

CHARCOAL) CAN RESULT IN CARBON MONOXIDE 

POISONING, WHICH MAY LEAD TO DEATH! 
Carbon Monoxide Poisoning – Early signs of carbon 

monoxide poisoning resemble the flu with headaches, 

dizziness, or nausea. If you have these signs, get 

fresh air at once!  Have the appliance inspected by a 

qualified service technician.  Some people are more 

affected by carbon monoxide than others.  These 

include pregnant women, people with heart or lung 

disease or anemia, those under the influence of al-

cohol, and those at high altitudes.

Ventilation Requirements - Provide adequate air for 

combustion. The fresh air requirements of this ap-

pliance must be met within the space where it will 

be installed.

Smoke Detectors - Since there are always several 

potential sources of fire in any home, we recommend 

installing smoke detectors. If possible, install the 

smoke detector in a hallway adjacent to the room (to 

reduce the possibility of occasional false activation 

from the heat produced by the appliance).  If your local 

code requires a smoke detector be installed within the 

same room, you must follow the requirements of your 

local code. Check with your local building department 

for requirements in your area.

Creosote – Formation and Need for Removal 

When wood is burned slowly, it produces tar and other 

organic vapors, which combine with expelled moisture 

to form creosote. The creosote vapors condense in 

the relatively cool chimney flue of a slow-burning 

fire. As a result, creosote residue accumulates on 

the flue lining. When ignited this creosote makes an 

extremely hot fire. 

The chimney shall be inspected at least twice a 

year during the heating season to determine when a 

creosote buildup has occurred.  When creosote has 

accumulated (1/8" [3 mm] or more) it shall be removed 

to reduce the risk of a chimney fire.

Содержание WCT2036WS

Страница 1: ...The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autor...

Страница 2: ...tested for the fireplace system you may cause a fire hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace componen...

Страница 3: ...oseasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT...

Страница 4: ...T LESS THAN 14 356 mm TO PERPENDICULAR SIDEWALL OUTSIDE AIR LEFT SIDE ONLY GAS LINE KNOCK OUT ROUND TOP TERMINATION SQUARE CHASE TOP TERMINATION AIR KIT KNOCK OUT 13 7 8 353 mm 9 1 8 232 mm 3 4 19 mm...

Страница 5: ...iling flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth extensi...

Страница 6: ...l Safe Zone For Projection of Combustible Materials Upper Section of Circulating Fireplace Top of Louvered Opening Fireplace Opening Note Drawing Not to Scale 8 204 mm 1 26 mm Min 12 305 mm from Perpe...

Страница 7: ...eceptacle and Ground Sheet Metal Screws Figure 7 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of x 20 7 mm x 508 mm in size Air Inlet Location Must Allow For Bushes or Snow V...

Страница 8: ...cal chimney pipe supported ONLY by the fireplace must not exceed 20 feet Chimney heights above 20 feet must be supported USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combina...

Страница 9: ...Elbow Offset Elbow Offset Elbow Offset Elbow 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m A B C Ceiling Support Pipe 12S 8DM Ceiling Support Pipe 12S 8DM Figure 10 Cei...

Страница 10: ...A Screws OFFSET RISE CHIMNEY LENGTH A B 48 36 24 18 12 4 3 8 16 3 8 ELBOW SET ONLY 9 25 3 4 1 11 7 8 31 1 15 37 3 8 1 16 3 4 40 1 2 1 1 20 47 1 8 1 22 5 8 52 1 8 1 1 25 1 2 57 7 8 1 27 5 8 62 1 1 30...

Страница 11: ...l it is snug against open edge of flashing see Figure 16 Use SC1 for all round termina tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 16 Storm Collar Chimney P...

Страница 12: ...shroud is to be installed contact manufacturer for specifications 24 610 mm Min 24 610 mm Min 18 458 mm Min Typ Figure 18 Multiple Chase Installation 10 3 05 m 10 3 05 m 2 0 61 m Min 2 0 61 m Min 3 0...

Страница 13: ...ment Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap...

Страница 14: ...h glass doors operates much differently than a fireplace with an open front A fireplace with glass doors has a limited amount of air for combustion Excessive heat within fireplace can result if too la...

Страница 15: ...used if installed in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accor dance with instructions provided with the...

Страница 16: ...16 PARTS WOOD BURNING FIREPLACE MODELS WRT2036WS WRT2036WSI WCT2036WS WCT2036WSI MODEL CAT NO WRT2036WS F0683 WRT2036WSI F0684 WCT2036WS F0685 WCT2036WSI F0686 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18...

Страница 17: ...ner 1 13 See Page 18 Right Side Brick Liner 1 14 See Page 18 Bottom Brick Liner 1 15 See Page 18 Front Bottom Brick Liner 1 16 J6937 Blower Access Plate 1 17 J6895 Refractory Retainer 2 18 Top Insulat...

Страница 18: ...to obtain any of these parts Never use substitute materials not ap proved by IHP Use of non approved parts can result in poor performance and safety hazards 1 2 4 3 6 5 ACCESSORIES REFRACTORY STAIN K...

Страница 19: ...Snap Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT...

Страница 20: ...UVERS AND SLIP SECTION F0921 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE T...

Страница 21: ...nditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the app...

Страница 22: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Страница 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Страница 24: ...6628 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...

Отзывы: