Figure 26 - Locating Access Cover Plate

Access 

Panel

LOCATING ACCESS COVER PLATE

Sheet metal cover plates located underneath front hearth refractory may 

have shifted or moved out of place while fireplace was in transit. These 

cover plates must be kept in the proper location prior to using the fireplace 

(See Figure 26). 
For further operating guidelines, instructions and warranty informa-

tion, please refer to your homeowner's guide or contact your dealer.

REPLACEMENT PARTS

See Pages 16 to 18 for a complete replacement parts list. Use only 

parts supplied from the manufacturer.
Normally, all parts should be ordered through your IHP distributor 

or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1. The model number of the fireplace.

2. The serial number of the fireplace.

3. The part number.

4. The description of the part.

5. The quantity required.

6. The installation date of the fireplace.
If you encounter any problems or have any questions concerning the 

installation or application of this fireplace, please contact your dealer.

IHP

1769 East Lawrence Street

Russellville, AL 35654

Visit us at SuperiorFireplaces.us.com

TECHNICAL SERVICE

You may have further questions about installation, operation, or 

troubleshooting. Please contact your IHP dealer for any questions 

or concerns. When contacting your dealer please have your model 

and serial numbers of your fireplace ready. You can also visit our 

web site at 

SuperiorFireplaces.us.com

.

IMPORTANT NOTICE

A manufactured shroud which has been approved by a 

national testing agency for use with this fireplace may 

be used if installed in accordance with the instructions 

by its manufacturer. A locally fabricated shroud may be 

used with IHP Shroud Leg Spacer Kit (SLK) in accor-

dance with instructions provided with the shroud.

NOTICE: The firebox canopy (hood) must not be modified 

or replaced with a canopy that may be provided with the 

unvented decorative room heater.

CAUTION: THE STRUCTURAL INTEGRITY OF THE MANU-

FACTURED HOME FLOOR, WALL, AND CEILING/ROOF 

MUST BE MAINTAINED.

 

 

WARNING: DO NOT INSTALL IN SLEEPING ROOM OF 

MOBILE HOMES.

Canadian code CAN/ULC-S610-M87 and other pertinent codes require stain-

less steel chimney for the installation of this fireplace. A Cold Air Climate 

Kit is also required in Canada and is recommended for cooler regions in the 

United States. Below, find a list of approved stainless steel parts.

Chimney Parts List for Canada

Catalog 

No.

Model No. 8" Hi-Temp  

Wood burning Chimney

F0881

12-8HT

12" Section Hi-Temp Double Wall Pipe Snap Lock

F0882

18-8HT

18" Section Hi-Temp Double Wall Pipe Snap Lock

F0883

24-8HT

24" Section Hi-Temp Double Wall Pipe Snap Lock

F0884

36-8HT

36" Section Hi-Temp Double Wall Pipe Snap Lock

F0885

48-8HT

48" Section Hi-Temp Double Wall Pipe Snap Lock

F0886

30E-8HT

30 Degree Hi-Temp Offset and Return

F0887

12S-8HT

Hi-Temp Chimney Support (For Use With Chimney 

Heights In Excess of 30')

F0888

RT-8HT

Hi-Temp Round Top with Mesh Screen

F0889

RTT-8HT*

Hi-Temp Round Top with Mesh Screen and Slip 

Section

F0890

RLT-8HT

Hi-Temp Round Top with Louvered Screen

F0891

RLTT-8HT* Hi-Temp Round Top with Louvered Screen and 

Slip Section

F0892

ET-8HT*

Hi-Temp Pyramid Top with Slip Section

F0893

ETL-8HT*

Hi-Temp Large Pyramid Top with Slip Section (use 

with all 8" systems)

F0894

AP-8HT

Hi-Temp Anchor Plate/Collar Assembly (for ma-

sonry fireplaces)

F0929

CAK-8

Cold Air Collar Kit - 8" Chimney

*When ordered alone, this part cannot ship via parcel delivery services.

IMPORTANT NOTICES - CANADA

Содержание WCT2036WS

Страница 1: ...The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autor...

Страница 2: ...tested for the fireplace system you may cause a fire hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace componen...

Страница 3: ...oseasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT...

Страница 4: ...T LESS THAN 14 356 mm TO PERPENDICULAR SIDEWALL OUTSIDE AIR LEFT SIDE ONLY GAS LINE KNOCK OUT ROUND TOP TERMINATION SQUARE CHASE TOP TERMINATION AIR KIT KNOCK OUT 13 7 8 353 mm 9 1 8 232 mm 3 4 19 mm...

Страница 5: ...iling flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth extensi...

Страница 6: ...l Safe Zone For Projection of Combustible Materials Upper Section of Circulating Fireplace Top of Louvered Opening Fireplace Opening Note Drawing Not to Scale 8 204 mm 1 26 mm Min 12 305 mm from Perpe...

Страница 7: ...eceptacle and Ground Sheet Metal Screws Figure 7 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of x 20 7 mm x 508 mm in size Air Inlet Location Must Allow For Bushes or Snow V...

Страница 8: ...cal chimney pipe supported ONLY by the fireplace must not exceed 20 feet Chimney heights above 20 feet must be supported USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combina...

Страница 9: ...Elbow Offset Elbow Offset Elbow Offset Elbow 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m A B C Ceiling Support Pipe 12S 8DM Ceiling Support Pipe 12S 8DM Figure 10 Cei...

Страница 10: ...A Screws OFFSET RISE CHIMNEY LENGTH A B 48 36 24 18 12 4 3 8 16 3 8 ELBOW SET ONLY 9 25 3 4 1 11 7 8 31 1 15 37 3 8 1 16 3 4 40 1 2 1 1 20 47 1 8 1 22 5 8 52 1 8 1 1 25 1 2 57 7 8 1 27 5 8 62 1 1 30...

Страница 11: ...l it is snug against open edge of flashing see Figure 16 Use SC1 for all round termina tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 16 Storm Collar Chimney P...

Страница 12: ...shroud is to be installed contact manufacturer for specifications 24 610 mm Min 24 610 mm Min 18 458 mm Min Typ Figure 18 Multiple Chase Installation 10 3 05 m 10 3 05 m 2 0 61 m Min 2 0 61 m Min 3 0...

Страница 13: ...ment Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap...

Страница 14: ...h glass doors operates much differently than a fireplace with an open front A fireplace with glass doors has a limited amount of air for combustion Excessive heat within fireplace can result if too la...

Страница 15: ...used if installed in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accor dance with instructions provided with the...

Страница 16: ...16 PARTS WOOD BURNING FIREPLACE MODELS WRT2036WS WRT2036WSI WCT2036WS WCT2036WSI MODEL CAT NO WRT2036WS F0683 WRT2036WSI F0684 WCT2036WS F0685 WCT2036WSI F0686 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18...

Страница 17: ...ner 1 13 See Page 18 Right Side Brick Liner 1 14 See Page 18 Bottom Brick Liner 1 15 See Page 18 Front Bottom Brick Liner 1 16 J6937 Blower Access Plate 1 17 J6895 Refractory Retainer 2 18 Top Insulat...

Страница 18: ...to obtain any of these parts Never use substitute materials not ap proved by IHP Use of non approved parts can result in poor performance and safety hazards 1 2 4 3 6 5 ACCESSORIES REFRACTORY STAIN K...

Страница 19: ...Snap Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT...

Страница 20: ...UVERS AND SLIP SECTION F0921 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE T...

Страница 21: ...nditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the app...

Страница 22: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Страница 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Страница 24: ...6628 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...

Отзывы: