Draft Requirements

Your wood-burning appliance is dependent upon a properly func-

tioning chimney for optimum performance. It is important to match 

the wood-burning appliance to the chimney. The chimney has two 

functions: 

1. It draws combustion air into the appliance (without air, no fuel 

will burn) and 

2. It exhausts combustion by-products. Your new appliance is what 

is known as a “natural draft” appliance. 

The appliance depends solely on the natural draft of the chimney 

system to draw combustion air into the unit. Draft is the force that 

moves air from the appliance up into the chimney. The amount of 

draft in your chimney depends on the length of the chimney, local 

geography, nearby obstructions and other factors. Too much draft 

may cause excessive temperatures in the appliance (overfiring). Slow 

or inadequate draft equals poor combustion and possible smoking 

problems. The following are some conditions that may contribute 

to poor chimney draft: 

1. A chimney too large for your appliance. 

2. A chimney with not enough height to produce adequate draft.

3. A chimney with excessive height (this may allow exhaust to cool 

too much before exiting, which will stall the rate the exhaust exits). 

4. Offsets in the venting system are too restrictive 

(see Chimney 

Guidelines

).

Inadequate draft will cause the appliance to leak smoke into the room 

through the wood-burning appliance and the chimney connector joints. 

Excessive draft may cause an uncontrollable burn or a glowing red 

appliance or chimney part. 

Overfiring Damage -

 If the appliance or chimney connector glows, 

you are overfiring. Other symptoms may include: Cracking, warping 

or burning out of components, plated accessories may turn color, 

appliance glass may develop a haze, which will not come off with 

cleaning.
Overfiring of a appliance is a condition where excessive tempera-

tures are reached, beyond the design capabilities of the appliance. 

The damage that occurs from overfiring is not covered under the 

manufacturer’s limited warranty.
Also see Troubleshooting on Page 22.

Selecting the Proper Venting System

The appliance is merely one component of a larger system. The 

other equally important component is the venting system. This is 

necessary for achieving the required flow of combustion air to the fire 

chamber and for safely removing unwanted combustion by products 

from the appliance.
If the venting system’s design does not promote these ends, the system 

may not function properly. Poorly functioning venting systems may 

create performance problems as well as be a safety hazard.  

A draft 

test should read greater than .04’ W.C. (inches water column) and 

less than .08” W.C.

  As per NFPA-211 standard, the installer must 

 WARNING 

Neither the manufacturer nor the seller warrants “smoke 

free” operation nor are we responsible for inadequate 

system draft caused by mechanical systems, general 

construction conditions, inadequate chimney heights, 

adverse wind conditions and/or unusual environmental 

factors or conditions beyond our control. 

take into account all variables within the installation and install the 

appliance in such a manner that satisfies the draft requirements of 

the appliance. See Chimney Guidelines to assist you in selecting the 

proper venting system for your installation.

American National Standards Institute ANSI/NFPA 211, Standard 

for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appli-

ances - See Draft Section:

  A chimney or vent shall be so designed 

and constructed to develop a flow sufficient to completely remove all 

flue and vent gases to the outside atmosphere. The venting system 

shall satisfy the draft requirements of the connected appliance in 

accordance with the manufacturer’s instructions.

Chimney Guidelines:

•  In well insulated and weather tight homes, it may be difficult to 

establish a good draft up your chimney. The poor draft is caused 

by a shortage of air in the house.  In this situation an Outside Air 

Kit may need to be installed (See Negative Pressure Warning be-

low and Outside Combustion Air in the Installation and Operation 

manual).

Negative Pressure Warning

These appliances are not designed to be operated in a negative 

pressure. In very airtight homes with large kitchen exhaust fans, 

furnace cold air returns, fresh air exchange systems and any other 

air system in close proximity to the heating appliance may create a 

negative pressure in the same room as the heating appliance. This can 

create dangerous back drafting of the appliance and chimney joints, 

drawing combustion by-products into the home. Be sure your home 

has adequate makeup air to eliminate negative pressures caused by 

the above-mentioned sources. Outside air connected to the appliance 

probably will not resolve such a problem as the appliance is not the 

source of negative pressure. IHP accepts no liability for damages 

resulting from negative pressures described here.

Ventilation Requirements -

 Provide adequate air for combustion. 

The fresh air requirements of this appliance must be met within the 

space where it will be installed. Ventilation is essential when using 

a solid-fuel-burning appliance.  In well insulated and weather tight 

homes, it may be difficult to establish a good draft up the chimney 

(caused by a shortage of air in the home). The lack of air is caused 

by many common household appliances which exhaust air from the 

home (such as a furnace, heat pump, air conditioner, clothes dryer, 

exhaust fans, fireplaces, and other fuel burning appliances). Also, the 

combustion process of this appliance uses oxygen from inside the 

dwelling.  If the available fresh air delivery in the dwelling is insufficient 

to support the demands of these appliances, problems can result 

(i.e. excessive negative pressure can develop in the dwelling which 

will affect the rate at which this appliance can draft thus resulting 

in performance problems or smoking.  To correct this problem it 

may help to open a window (preferably on the windward side of the 

house) or install an outside air kit.

Содержание WCT2036WS

Страница 1: ...The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autor...

Страница 2: ...tested for the fireplace system you may cause a fire hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace componen...

Страница 3: ...oseasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT...

Страница 4: ...T LESS THAN 14 356 mm TO PERPENDICULAR SIDEWALL OUTSIDE AIR LEFT SIDE ONLY GAS LINE KNOCK OUT ROUND TOP TERMINATION SQUARE CHASE TOP TERMINATION AIR KIT KNOCK OUT 13 7 8 353 mm 9 1 8 232 mm 3 4 19 mm...

Страница 5: ...iling flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth extensi...

Страница 6: ...l Safe Zone For Projection of Combustible Materials Upper Section of Circulating Fireplace Top of Louvered Opening Fireplace Opening Note Drawing Not to Scale 8 204 mm 1 26 mm Min 12 305 mm from Perpe...

Страница 7: ...eceptacle and Ground Sheet Metal Screws Figure 7 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of x 20 7 mm x 508 mm in size Air Inlet Location Must Allow For Bushes or Snow V...

Страница 8: ...cal chimney pipe supported ONLY by the fireplace must not exceed 20 feet Chimney heights above 20 feet must be supported USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combina...

Страница 9: ...Elbow Offset Elbow Offset Elbow Offset Elbow 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m A B C Ceiling Support Pipe 12S 8DM Ceiling Support Pipe 12S 8DM Figure 10 Cei...

Страница 10: ...A Screws OFFSET RISE CHIMNEY LENGTH A B 48 36 24 18 12 4 3 8 16 3 8 ELBOW SET ONLY 9 25 3 4 1 11 7 8 31 1 15 37 3 8 1 16 3 4 40 1 2 1 1 20 47 1 8 1 22 5 8 52 1 8 1 1 25 1 2 57 7 8 1 27 5 8 62 1 1 30...

Страница 11: ...l it is snug against open edge of flashing see Figure 16 Use SC1 for all round termina tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 16 Storm Collar Chimney P...

Страница 12: ...shroud is to be installed contact manufacturer for specifications 24 610 mm Min 24 610 mm Min 18 458 mm Min Typ Figure 18 Multiple Chase Installation 10 3 05 m 10 3 05 m 2 0 61 m Min 2 0 61 m Min 3 0...

Страница 13: ...ment Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap...

Страница 14: ...h glass doors operates much differently than a fireplace with an open front A fireplace with glass doors has a limited amount of air for combustion Excessive heat within fireplace can result if too la...

Страница 15: ...used if installed in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accor dance with instructions provided with the...

Страница 16: ...16 PARTS WOOD BURNING FIREPLACE MODELS WRT2036WS WRT2036WSI WCT2036WS WCT2036WSI MODEL CAT NO WRT2036WS F0683 WRT2036WSI F0684 WCT2036WS F0685 WCT2036WSI F0686 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18...

Страница 17: ...ner 1 13 See Page 18 Right Side Brick Liner 1 14 See Page 18 Bottom Brick Liner 1 15 See Page 18 Front Bottom Brick Liner 1 16 J6937 Blower Access Plate 1 17 J6895 Refractory Retainer 2 18 Top Insulat...

Страница 18: ...to obtain any of these parts Never use substitute materials not ap proved by IHP Use of non approved parts can result in poor performance and safety hazards 1 2 4 3 6 5 ACCESSORIES REFRACTORY STAIN K...

Страница 19: ...Snap Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT...

Страница 20: ...UVERS AND SLIP SECTION F0921 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE T...

Страница 21: ...nditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the app...

Страница 22: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Страница 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Страница 24: ...6628 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...

Отзывы: